Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Instrumentation and Measurement

Multifunctional Metafiber for Pumping SERF Atomic Magnetometer

Qingcheng Song, Wenlin Luan, Ying Liu, Lihong Duan, Xia Yu

Published Jan 1, 2025• 5 citations
Publisher

Abstract

Miniaturized spin-exchange relaxation-free (SERF) atomic magnetometer is an ultra-sensitive device for biomagnetic dynamic measurements, yet it still remains challenging in realizing easy-to-align and compact optical configuration while maintaining high sensitivity. In this study, we demonstrate a multi-functional metafiber, consisting of a compact metalens assembled on the facet of an optical fiber, for flexible and high-performance pump light delivery and manipulation in atomic magnetometers for the first time. By tailoring transmission and phase profiles of nanopillars, the metafiber simultaneously enables broadband collimation and polarization manipulation from 770 to 894 nm, a spectrum regime that covers most commonly used alkali metals in quantum technologies. We integrate the metafiber with a SERF atomic magnetometer and achieve magnetic field measurement with a sensitivity of 51.12 fTHz−1/2(@31.5 Hz). Beyond optically interfaced quantum systems, the demonstrated highly compact and easy-to-align multifunctional metafiber can also find widespread classical applications such as wavelength-multiplexing fiber-optic communications, fiber sensing and fiber lasers.

DOI
10.1109/tim.2025.3571149

Related papers

High spatial resolution multi-channel optically pumped atomic magnetometer based on a spatial light modulator

Xiujie Fang, Kai Wei, Tian Zhao +5 more

Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.

Optics Express•Aug 14, 2020•46 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•62 citations

In-situ determination of spin polarization in a single-beam fiber-coupled spin-exchange-relaxation-free atomic magnetometer with differential detection

Yintao Ma, Zhixia Qiao, Yao Chen +8 more

The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.

Optics Express•Jan 9, 2023•5 citations

Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell

Yibo Qi, Bo Li, Shuying Wang +3 more

Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz$^{1/2}$) was 1.89 times that of the single-pass configuration (3.4 fT/Hz$^{1/2}$), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•18 citations

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•273 citations

Performance Characterization and Optimization of a Miniaturized SERF Atomic Magnetometer via Tunable Laser Power

Peng Shi, Chen Zuo, Qisong Li +1 more

Spin-exchange relaxation-free (SERF) atomic magnetometers have emerged as highly promising candidates for ultra-weak magnetic field detection, particularly in biomagnetic imaging, owing to their exceptional sensitivity, amenability to miniaturization, and near-room-temperature operation. While current miniaturized magnetometers typically employ laser chips with fixed optical power, the quantitative impact of laser power on critical performance metrics remains to be fully elucidated. This study systematically investigates the influence of laser power on sensitivity, bandwidth, and dynamic range by incorporating considerations of power broadening, saturation absorption, and noise constraints. A miniaturized probe, integrated with an actively controlled vertical-cavity surface-emitting laser (VCSEL), was developed for experimental validation. Theoretical and experimental results consistently demonstrate that as optical power increases, sensitivity exhibits a non-monotonic dependence, whereas both bandwidth and dynamic range manifest a monotonic upward trend, aligning well with theoretical simulations. The optimized sensor achieved a peak sensitivity of 16 fT/√Hz at 300 μW, while the bandwidth and dynamic range reached 230 Hz and ±5.4 nT at 500 μW, respectively. This work establishes a robust theoretical and experimental framework for the comprehensive performance optimization of laser-integrated miniaturized atomic magnetometers.

Sensors•Mar 23, 2026•0 citations
Miniaturized spin-exchange relaxation-free (SERF) atomic magnetometer is an ultra-sensitive device for biomagnetic dynamic measurements, yet it still remains challenging in realizing easy-to-align and compact optical configuration while maintaining high sensitivity. In this study, we demonstrate a multi-functional metafiber, consisting of a compact metalens assembled on the facet of an optical fiber, for flexible and high-performance pump light delivery and manipulation in atomic magnetometers for the first time. By tailoring transmission and phase profiles of nanopillars, the metafiber simultaneously enables broadband collimation and polarization manipulation from 770 to 894 nm, a spectrum regime that covers most commonly used alkali metals in quantum technologies. We integrate the metafiber with a SERF atomic magnetometer and achieve magnetic field measurement with a sensitivity of 51.12 fTHz−1/2(@31.5 Hz). Beyond optically interfaced quantum systems, the demonstrated highly compact and easy-to-align multifunctional metafiber can also find widespread classical applications such as wavelength-multiplexing fiber-optic communications, fiber sensing and fiber lasers.
Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz 1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.
Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz1/2^{1/2}1/2) was 1.89 times that of the single-pass configuration (3.4 fT/Hz1/2^{1/2}1/2), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.
Spin-exchange relaxation-free (SERF) atomic magnetometers have emerged as highly promising candidates for ultra-weak magnetic field detection, particularly in biomagnetic imaging, owing to their exceptional sensitivity, amenability to miniaturization, and near-room-temperature operation. While current miniaturized magnetometers typically employ laser chips with fixed optical power, the quantitative impact of laser power on critical performance metrics remains to be fully elucidated. This study systematically investigates the influence of laser power on sensitivity, bandwidth, and dynamic range by incorporating considerations of power broadening, saturation absorption, and noise constraints. A miniaturized probe, integrated with an actively controlled vertical-cavity surface-emitting laser (VCSEL), was developed for experimental validation. Theoretical and experimental results consistently demonstrate that as optical power increases, sensitivity exhibits a non-monotonic dependence, whereas both bandwidth and dynamic range manifest a monotonic upward trend, aligning well with theoretical simulations. The optimized sensor achieved a peak sensitivity of 16 fT/√Hz at 300 μW, while the bandwidth and dynamic range reached 230 Hz and ±5.4 nT at 500 μW, respectively. This work establishes a robust theoretical and experimental framework for the comprehensive performance optimization of laser-integrated miniaturized atomic magnetometers.