In the application of weak measurements, such as the estimation of magnetic parameters, the purely real weak coupling of standard weak measurement (SWM) does not correspond to the true physical parameters. To accommodate more complex application scenarios, we further explore three different weak measurement models in which both complex weak coupling and complex weak values coexist. This paper theoretically analyzes pointer variations and applicable ranges in SWM, double pointer weak measurement (DPWM), and almost-balanced weak measurement (ABWM) under specific conditions. Notably, only ABWM can successfully distinguish the real and imaginary components of weak values under complex weak-coupling conditions. While SWM and DPWM can also solve for weak values, they fail to obtain a unique and correct test value. The ABWM technique provides a higher sensitivity than SWM when measuring extremely small parameters. Furthermore, we apply ABWM to the magneto-optical Kerr effect measurement of a Ni-Fe film. This research deepens the understanding of weak measurement techniques and introduces new methods for multiparameter measurements.
In the application of weak measurements, such as the estimation of magnetic parameters, the purely real weak coupling of standard weak measurement (SWM) does not correspond to the true physical parameters. To accommodate more complex application scenarios, we further explore three different weak measurement models in which both complex weak coupling and complex weak values coexist. This paper theoretically analyzes pointer variations and applicable ranges in SWM, double pointer weak measurement (DPWM), and almost-balanced weak measurement (ABWM) under specific conditions. Notably, only ABWM can successfully distinguish the real and imaginary components of weak values under complex weak-coupling conditions. While SWM and DPWM can also solve for weak values, they fail to obtain a unique and correct test value. The ABWM technique provides a higher sensitivity than SWM when measuring extremely small parameters. Furthermore, we apply ABWM to the magneto-optical Kerr effect measurement of a Ni-Fe film. This research deepens the understanding of weak measurement techniques and introduces new methods for multiparameter measurements.
In this paper, a method to measure the tiny spin splitting of the spin Hall effect of light (SHEL) using the almost-balanced weak measurement (ABWM) is presented. The ABWM technique uses two orthogonal post-selected states to record all of the information, which is a precise measurement method being different from the standard weak measurement (SWM). The theory model to describe the SHEL measurement based on ABWM is established. As results, the ABWM scheme has a larger amplification factor, reaching ∼105, which is nearly one order of magnitude higher than that of the SWM. When the post-selected angle is less than a certain value, the sensitivity and amplification factor of the ABWM scheme are higher than those of the SWM scheme, while the measurement precision and SNR of the ABWM technique are comparable to those of the SWM scheme. This research may have great potential for the precision metrology or sensing field based on the SHEL measurement.
In this paper, we propose a weak measurement method using two pointers to estimate the magneto-optical Kerr angle, which is robust to ellipticity. The double pointers are the amplified displacement shift and intensity of the post-selected light beam, which are the conventional information carried by the light beam and can be directly output by a detector (such as a charge-coupled device). We demonstrate that the product of the double pointers is only related to the phase variation between two basic vectors and independent of the amplitude errors. In the measurement process, when there is an amplitude change or additional amplitude noise between two eigenstates, the product of two pointers is very useful in extracting phase information and shielding amplitude noise. In addition, the product of two pointers has a good linear relationship with the phase variation and a larger dynamic measurement range. This method is applied to measure the magneto-optical Kerr angle of NiFe film. The Kerr angle can be directly obtained using the product of the light intensity and the amplified displacement shift. This scheme is of great significance for the measurement of the Kerr angle of magnetic films.
Magneto-optical (MO) effects, manifested as a complex rotation of light polarization under an external magnetic field, are widely utilized in optical isolators, sensors, data storage, and magnetic imaging. Accurate measurement of both the rotation angle (the real part) and the ellipticity (the imaginary part) is essential for fundamental research and device applications. However, existing measurement schemes generally cannot determine these two quantities simultaneously within a single experimental process. In this work, we propose a scheme based on weak measurement using two pointers, enabling the simultaneous measurement of the rotation angle and ellipticity within a single meter state. This method was experimentally implemented to measure the magneto-optical Kerr effect under various configurations—longitudinal, polar, and transverse. Moreover, the proposed approach is also applicable to the measurement of the Faraday effect and magnetic linear birefringence, demonstrating its broad applicability. This work contributes to the advancement of high-precision measurement techniques for MO effects and supports their wider application across multiple fields.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
The present paper introduces a quantum weak measurement (WM) scheme for the measurement of the complex magneto-optical Kerr effect (MOKE). We achieve the simultaneous measurement of the Kerr rotation angle and the ellipticity in a single WM process by utilizing two auxiliary pointers derived from the same meter state. The experimental measurement precision for both the Kerr rotation angle and the ellipticity is capable of reaching 10−4 deg. This technique is also employed for the determination of the complex magneto-optical constant Q. The proposed method overcomes the limitation of acquiring the complex magneto-optical Kerr parameters through a multi-step measurement process, which was previously encountered. This breakthrough holds immense significance for efficiently measuring and applying the complex MOKE with high precision and cost-effectiveness.
Magneto-optical (MO) effects, manifested as a complex rotation of light polarization under an external magnetic field, have found renewed and advanced applications in integrated photonics, intelligent sensing, ultrafast magnetic recording, and high-resolution magnetic imaging. Accurate measurement of both the rotation angle (the real part) and the ellipticity (the imaginary part) is essential for fundamental research and device applications. However, existing measurement schemes generally require separate measurements or distinct detection configurations and therefore cannot simultaneously retrieve both quantities in a single measurement. In this work, we propose a scheme based on weak measurement using dual-pointers, enabling the simultaneous measurement of the rotation angle and ellipticity within a single meter state. This method was theoretically and experimentally implemented to measure the magneto-optical Kerr effect (MOKE), the Faraday effect, and the Cotton-Mouton effect, demonstrating its broad applicability. This work contributes a characterization technique for the complex angle of MO effects, supporting potential applications across spintronics, quantum materials, and advanced optical sensing.