Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Accessing magnetic fields with dual-channel weak measurements

Yinghang Jiang, Jiguo Wu, Rong-Chun Ge, Zhiyou Zhang

Published Apr 1, 2025• 6 citations
Publisher

Abstract

As a promising candidate for precision quantum metrology, recently, quantum weak measurement assisted magnetometers have shown potential advantage in enhancing sensitivity to small polarization changes. In this Letter, we propose a quantum weak measurement scheme for atomic magnetometers. To successfully address the challenges of both multi-parameter disturbance and high-frequency signal detection, a strategy of dual-channel weak measurement is employed in our experimental design. Our experimental data show clear improvement of the sensitivity in both DC and AC magnetic field detection. A deliberate comparison between our dual-channel weak measurement and the balanced detection scheme when subjected to the same experimental conditions shows that a much higher sensitivity is achieved in the dual-channel scheme, and an improvement of one order of magnitude is confirmed in the experiment.

DOI
10.1364/ol.555399

Related papers

Spin-exchange relaxation-free magnetometer enhanced by biased weak measurement

Qian Cao, Shang Yu, Liang Xu +1 more

In quantum metrology researching, weak measurement has been widely applied in many aspects, providing weak-value amplification and noise suppressing ability. Recently, several modified schemes of weak measurement have been proposed, such as inverse, almost-balanced, and biased weak measurement. In this study, we enhance a spin-exchange relaxation-free (SERF) magnetometer using the biased weak measurement metrology technique. We establish and simulate a biased weak measurement (BWM)-enhanced SERF magnetometer model. By adjusting the pre-coupling process and analysing the Fisher information, higher sensitivity to magnetic fields is verified in this study. 0.003 fT can be achieved through adjusting pre-coupling process and extinction ratio, which is higher than the best sensitivity of SERF magnetometer in existence. Our work paves the way for embedding weak measurement techniques into atomic magnetometer sensors and greatly improving their sensitivity.

Results in Physics•Apr 2, 2024•4 citations

Magnetic field sensing based on multi-order resonances of atomic spins

Hongying Yang, Qian Wang, Binbin Zhao +4 more

Broad-dynamic-range magnetometers are demanded in practical applications and fundamental research. We experimentally demonstrate a parametrically modulated atomic magnetometer with a large dynamic range by taking advantage of the high-order resonance effects. With the increase of the strength of the modulation field, both low-order and high-order resonances are well resolved and used to measure the DC or AC magnetic fields. The experimentally demonstrated sensitivity of the magnetometer based on the zeroth-order resonance is 1.5 pT/Hz, and those based on the high-order resonances are below 3 pT/Hz, making the measurement of high magnetic fields feasible under an open-loop operation. Moreover, we also demonstrated the measurement of high-frequency large AC magnetic field with the high-order resonances, and the sensitivity for the AC magnetic field based on the first-order resonance is 7 pT/Hz. Our scheme provides a new path for the development of broad-dynamic-range and miniaturized atomic magnetometers.

Optics Express•Nov 22, 2021•6 citations

Inverse weak measurement in a SERF magnetometer

Qian Cao, Liang Xu, Ziqian Yue +2 more

Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.

arXiv:2508.12306•Photonics Research•Oct 27, 2025•5 citations

Zero-field atomic magnetometer to extract longitudinal magnetic field

Shuying Wang, Jixi Lu, Kaixuan Zhang +3 more

Zero-field atomic ensembles enable the development of ultrahigh-sensitivity magnetometry. However, their intrinsic insensitivity to longitudinal magnetic fields along the pumping direction poses a fundamental limitation, restricting precise weak-field quantification and complex system decoupling. Herein, we propose a novel zero-field weak parametric modulation scheme capable of ultrahigh-sensitivity extraction of longitudinal magnetic fields. Transverse modulation is employed to manifest the electron spin polarization projection induced by the longitudinal fields. Based on the perturbation model established, first-order parametric resonance associated with the longitudinal magnetic field yields significant signal enhancement under low-frequency and weak modulation conditions, while simultaneously suppressing spin-exchange relaxation caused by magnetic field modulation. We experimentally achieved a longitudinal measurement sensitivity of 16 fT / Hz 1 / 2 , more than an order of magnitude improved over traditional schemes, with a bandwidth of 70 Hz. Benefiting from low spin relaxation, the noise floor of the transverse magnetic field measurement is preserved at 4 fT / Hz 1 / 2 . The proposed scheme pushes the boundaries of existing weak magnetic field measurement, providing critical capabilities for state-of-the-art precision experiments including new physical quantity detection.

Physical Review Research•Jul 18, 2025•8 citations

Enhancing weak-magnetic-field sensing of a cavity-magnon system with dual frequency modulation

Zheng Liu, Yu‐qiang Liu, Zi-yi Mai +3 more

The crucial limitation of improving the sensitivity of the detection of weak magnetic fields is the unavoidable measurement noise. In this paper, we propose a scheme to achieve precise sensing robust against additional noise by employing a dual frequency bias field modulation within a cavity-magnon system. We find that the antirotating wave term can amplify the signal of the detected magnetic field, but this amplification effect must coexist with the rotating wave term. In particular, by the bias field modulation, we find the robustness against cavity field thermal noise is substantially enhanced, quantum noise and cavity field thermal noise is greatly reduced, and the external magnetic field signal is amplified, thereby improving the weak-magnetic-field sensing system's sensitivity. Compared with the previous scheme, our scheme requires neither an ultrastrong- or deep-strong-coupling mechanism nor the suppression of the additional noise by increasing the electromagnetic cooperativity. Our scheme could provide a valuable candidate for weak-magnetic-field sensing.

arXiv:2401.13879•Physical Review A•Feb 12, 2024•15 citations

Precision Magnetic Field Sensing with Dual Multi-Wave Atom Interferometer

Wenhua Yan, Xudong Ren, Min-Kang Zhou +1 more

Precision magnetic field measurement is widely used for practical applications, fundamental research, and medical purposes, etc. We propose a novel quantum magnetometer based on atoms' multi-wave (3-wave and 5-wave) Ramsey interference. Our design features high phase sensitivity and can be applied to in situ measurements of the magnetic field inside vacuum chambers. The final state detection is designed to be achieved by Raman's two-photon transition. The analytical solution for applicable interference fringe is presented. Fringe contrast decay due to atom temperature and magnetic field gradient is simulated to estimate reasonable experimental conditions. Sensitivity functions for phase noise and magnetic field noise in a multi-wave system are derived to estimate the noise level required to reach the expected resolution. The validity of the model, dual-channel features on bias estimation, and the quasi-non-destructive detection feature are discussed.

Sensors•Dec 24, 2022•4 citations
As a promising candidate for precision quantum metrology, recently, quantum weak measurement assisted magnetometers have shown potential advantage in enhancing sensitivity to small polarization changes. In this Letter, we propose a quantum weak measurement scheme for atomic magnetometers. To successfully address the challenges of both multi-parameter disturbance and high-frequency signal detection, a strategy of dual-channel weak measurement is employed in our experimental design. Our experimental data show clear improvement of the sensitivity in both DC and AC magnetic field detection. A deliberate comparison between our dual-channel weak measurement and the balanced detection scheme when subjected to the same experimental conditions shows that a much higher sensitivity is achieved in the dual-channel scheme, and an improvement of one order of magnitude is confirmed in the experiment.
In quantum metrology researching, weak measurement has been widely applied in many aspects, providing weak-value amplification and noise suppressing ability. Recently, several modified schemes of weak measurement have been proposed, such as inverse, almost-balanced, and biased weak measurement. In this study, we enhance a spin-exchange relaxation-free (SERF) magnetometer using the biased weak measurement metrology technique. We establish and simulate a biased weak measurement (BWM)-enhanced SERF magnetometer model. By adjusting the pre-coupling process and analysing the Fisher information, higher sensitivity to magnetic fields is verified in this study. 0.003 fT can be achieved through adjusting pre-coupling process and extinction ratio, which is higher than the best sensitivity of SERF magnetometer in existence. Our work paves the way for embedding weak measurement techniques into atomic magnetometer sensors and greatly improving their sensitivity.
Broad-dynamic-range magnetometers are demanded in practical applications and fundamental research. We experimentally demonstrate a parametrically modulated atomic magnetometer with a large dynamic range by taking advantage of the high-order resonance effects. With the increase of the strength of the modulation field, both low-order and high-order resonances are well resolved and used to measure the DC or AC magnetic fields. The experimentally demonstrated sensitivity of the magnetometer based on the zeroth-order resonance is 1.5 pT/Hz, and those based on the high-order resonances are below 3 pT/Hz, making the measurement of high magnetic fields feasible under an open-loop operation. Moreover, we also demonstrated the measurement of high-frequency large AC magnetic field with the high-order resonances, and the sensitivity for the AC magnetic field based on the first-order resonance is 7 pT/Hz. Our scheme provides a new path for the development of broad-dynamic-range and miniaturized atomic magnetometers.
Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.
Zero-field atomic ensembles enable the development of ultrahigh-sensitivity magnetometry. However, their intrinsic insensitivity to longitudinal magnetic fields along the pumping direction poses a fundamental limitation, restricting precise weak-field quantification and complex system decoupling. Herein, we propose a novel zero-field weak parametric modulation scheme capable of ultrahigh-sensitivity extraction of longitudinal magnetic fields. Transverse modulation is employed to manifest the electron spin polarization projection induced by the longitudinal fields. Based on the perturbation model established, first-order parametric resonance associated with the longitudinal magnetic field yields significant signal enhancement under low-frequency and weak modulation conditions, while simultaneously suppressing spin-exchange relaxation caused by magnetic field modulation. We experimentally achieved a longitudinal measurement sensitivity of 16 fT / Hz 1 / 2 , more than an order of magnitude improved over traditional schemes, with a bandwidth of 70 Hz. Benefiting from low spin relaxation, the noise floor of the transverse magnetic field measurement is preserved at 4 fT / Hz 1 / 2 . The proposed scheme pushes the boundaries of existing weak magnetic field measurement, providing critical capabilities for state-of-the-art precision experiments including new physical quantity detection.
The crucial limitation of improving the sensitivity of the detection of weak magnetic fields is the unavoidable measurement noise. In this paper, we propose a scheme to achieve precise sensing robust against additional noise by employing a dual frequency bias field modulation within a cavity-magnon system. We find that the antirotating wave term can amplify the signal of the detected magnetic field, but this amplification effect must coexist with the rotating wave term. In particular, by the bias field modulation, we find the robustness against cavity field thermal noise is substantially enhanced, quantum noise and cavity field thermal noise is greatly reduced, and the external magnetic field signal is amplified, thereby improving the weak-magnetic-field sensing system's sensitivity. Compared with the previous scheme, our scheme requires neither an ultrastrong- or deep-strong-coupling mechanism nor the suppression of the additional noise by increasing the electromagnetic cooperativity. Our scheme could provide a valuable candidate for weak-magnetic-field sensing.
Precision magnetic field measurement is widely used for practical applications, fundamental research, and medical purposes, etc. We propose a novel quantum magnetometer based on atoms' multi-wave (3-wave and 5-wave) Ramsey interference. Our design features high phase sensitivity and can be applied to in situ measurements of the magnetic field inside vacuum chambers. The final state detection is designed to be achieved by Raman's two-photon transition. The analytical solution for applicable interference fringe is presented. Fringe contrast decay due to atom temperature and magnetic field gradient is simulated to estimate reasonable experimental conditions. Sensitivity functions for phase noise and magnetic field noise in a multi-wave system are derived to estimate the noise level required to reach the expected resolution. The validity of the model, dual-channel features on bias estimation, and the quasi-non-destructive detection feature are discussed.