Optical and Quantum Sensing and Precision Metrology II

Slow-light augmented interferometry for precision measurement of frequency shifts

M. S. Shahriar

Published Mar 19, 2025• 0 citations
Publisher
DOI
10.1117/12.3053690

Related papers

Slow Light Augmented Unbalanced Interferometry for Extreme Enhancement in Sensitivity of Measuring Frequency Shift in a Laser

Ruoxi Zhu, Zifan Zhou, Jinyang Li +3 more

We demonstrate a slow-light augmented unbalanced Mach-Zehnder interferometer (MZI) which can be used to enhance very significantly the sensitivity of measuring the frequency shift in a laser. The factor of enhancement depends on the group index of the slow-light medium, the degree of imbalance between the physical lengths of the two arms of the MZI, and the spectral width of the laser. For a laser with a quantum noise limited spectral width, the group index has to be larger than the finesse of the laser cavity in order to achieve enhancement in measurement sensitivity. For the reported results, slow-light effect is produced by employing electro-magnetically induced transparency via coherent population trapping in a paraffin coated vapor cell of Rb atoms, with a maximum group index of ~2170. The maximum enhancement factor realized is ~70. This differs from the theoretically expected value of ~183 by a factor of ~2.6. This discrepancy can be attributed to effects of unidentified excess noise, and the fact that the test laser spectral width may not the quantum noise limited. Much larger values can potentially be obtained by modifying the apparatus, and using cold atoms for producing the slow-light effect. The sensitivity of any sensor that relies on measuring the frequency shift of a laser can be enhanced substantially using this technique. These include, but are not limited to, gyroscopes and accelerometers based on a conventional ring laser or a superluminal ring laser, and detectors for virialized ultra-light field dark matter.

arXiv:2403.05491•Mar 8, 2024•0 citations

Theoretical Study on high sensitivity slow light interferometer

掌蕴东 Zhang Yundong, 蔡元学 Cai Yuanxue, 杨超博 Yang Chaobo +3 more

High Power Laser and Particle Beams•Jan 1, 2010•0 citations

Slow Light Augmented Fabry-Perot Cavity for Enhanced Sensitivity in Measuring Frequency Shift

Zhu, Ruoxi, Zhou, Zifan, Greenwood, Dustin +3 more

Recently, it has been shown that a slow-light augmented unbalanced Mach-Zehnder interferometer (SLAUMZI) can be used to enhance significantly the sensitivity of measuring the frequency shift of a laser, compared to the heterodyne technique. Here, we show that a similar enhancement can be realized using a slow-light augmented Fabry-Perot Cavity (SLAFPC), due to the fact that an FPC is inherently unbalanced, since different bounces of the field traverse different path lengths before interfering with the other bounces. We show how the degree of enhancement in sensitivity depends on the spectral width of the laser and the finesse of the FPC. For potentially realizable conditions, we show that a sensitivity enhancement factor ~2.8*10^6 can be achieved using a SLAFPC.

arXiv:2506.15885•Jun 18, 2025•0 citations

A phase-modulated interferometer for high-precision spectroscopy

Andreas Wicht, M. Müller, Volker Quetschke +3 more

Applied Physics B•Jun 1, 2000•5 citations

EIT-augmented Unbalanced Mach-Zehnder Interferometer for Enhanced Sensitivity Frequency Measurement

Ruoxi Zhu, Zifan Zhou, Jinyang Li +1 more

We investigated the use of an unbalanced Mach-Zehnder interferometer augmented with slow-light-effect induced via electromagnetically induced transparency for enhanced-sensitivity measurement of frequency shift, and demonstrated conditions corresponding to an enhancement factor greater than ten thousand.

Frontiers in Optics•Jan 1, 2023•0 citations

Precision Measurements with Matter-wave Interferometry

Christopher Erickson, Dan Christensen, Matthew Washburn +5 more

Bulletin of the American Physical Society•Jun 8, 2007•0 citations
We demonstrate a slow-light augmented unbalanced Mach-Zehnder interferometer (MZI) which can be used to enhance very significantly the sensitivity of measuring the frequency shift in a laser. The factor of enhancement depends on the group index of the slow-light medium, the degree of imbalance between the physical lengths of the two arms of the MZI, and the spectral width of the laser. For a laser with a quantum noise limited spectral width, the group index has to be larger than the finesse of the laser cavity in order to achieve enhancement in measurement sensitivity. For the reported results, slow-light effect is produced by employing electro-magnetically induced transparency via coherent population trapping in a paraffin coated vapor cell of Rb atoms, with a maximum group index of ~2170. The maximum enhancement factor realized is ~70. This differs from the theoretically expected value of ~183 by a factor of ~2.6. This discrepancy can be attributed to effects of unidentified excess noise, and the fact that the test laser spectral width may not the quantum noise limited. Much larger values can potentially be obtained by modifying the apparatus, and using cold atoms for producing the slow-light effect. The sensitivity of any sensor that relies on measuring the frequency shift of a laser can be enhanced substantially using this technique. These include, but are not limited to, gyroscopes and accelerometers based on a conventional ring laser or a superluminal ring laser, and detectors for virialized ultra-light field dark matter.
Recently, it has been shown that a slow-light augmented unbalanced Mach-Zehnder interferometer (SLAUMZI) can be used to enhance significantly the sensitivity of measuring the frequency shift of a laser, compared to the heterodyne technique. Here, we show that a similar enhancement can be realized using a slow-light augmented Fabry-Perot Cavity (SLAFPC), due to the fact that an FPC is inherently unbalanced, since different bounces of the field traverse different path lengths before interfering with the other bounces. We show how the degree of enhancement in sensitivity depends on the spectral width of the laser and the finesse of the FPC. For potentially realizable conditions, we show that a sensitivity enhancement factor ~2.8*10^6 can be achieved using a SLAFPC.