Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Alexander Mavian, Yang Xu, Cheng Li, Robert W. Boyd

Published Dec 16, 2024• 9 citations
Publisher

Abstract

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

DOI
10.1364/ol.544786

Related papers

Toward video-rate quantum ghost imaging

Carsten Pitsch, Alessia Suprano, Benjamin Guery +10 more

Quantum Ghost Imaging (QGI) is a powerful imaging technique that enables probing of an object using illumination levels beyond classical limits and does not rely on a single-photon-sensitive camera in the spectrum of interest. Current “heralded” QGI setups provide high-resolution images with intensified charge-coupled device (ICCD) cameras, but their acquisition time and applicability are limited by setup complexity and detector dead time. Recently, new setups using single photon detection and time-tagging have been shown to allow more efficient acquisition while also enabling new applications, such as remote 3D imaging using “asynchronous” QGI. Here, we demonstrate novel results of two asynchronous QGI setups, using a dedicated high duty-cycle single photon avalanche diode array to drastically reduce acquisition time to sub-second regime, demonstrating video acquisition at 10 fps. As this scheme allows interoperability with arbitrary single photon timing detectors, it can be adapted to a variety of applications and is not bound by the detection window of silicon-based detectors. We further study the impact of the choice of bucket detector and pump laser, using readily available off-the-shelf detectors and lasers. Summarizing the findings, we discuss the remaining limitations for real-time imaging and give an outlook on upcoming developments and an outline of further applications of both detectors and detection scheme.

APL Photonics•Oct 1, 2025•4 citations

Sub-minute Quantum Ghost Imaging in the infrared enabled by a "looking back" SPAD array

Valerio Flavio Gili, Dupish Dupish, Vega, Andres +6 more

Quantum Ghost Imaging (QGI) is an intriguing imaging protocol that exploits photon-pair correlations stemming from spontaneous parametric down-conversion (SPDC). QGI retrieves images from two-path joint measurements, where single-path detection does not allow to reconstruct the target image. This technique, has been so far limited in terms of acquisition speed either by raster scanning, or by the slow electronics of intensified cameras. Here we report on a fast QGI implementation exploiting a SPAD array detector for the spatially resolving path, enabling the acquisition of a ghost image in under one minute. Moreover, the employment of non-degenerate SPDC allows to investigate samples at infrared wavelengths without the need for short-wave infrared (SWIR) cameras, while the spatial detection can be still performed in the visible region, where the more advanced silicon-based technology can be exploited. Our findings advance the state-of-the-art of QGI schemes towards practical applications.

arXiv:2211.12913•Nov 23, 2022•1 citation

EPR-based ghost imaging using a single-photon-sensitive camera

Reuben S. Aspden, D. S. Tasca, Robert W. Boyd +1 more

Correlated photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments, two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated photon ghost imaging experiments have scanned a single-pixel detector through the field of view to obtain spatial information. However, scanning leads to poor sampling efficiency, which scales inversely with the number of pixels, N , in the image. In this work, we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far field of the photon pair source, taking advantage of the Einstein–Podolsky–Rosen-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.

arXiv:1212.5059•New Journal of Physics•Jul 17, 2013•174 citations

Quantum Ghost Imaging of Remote Targets With Novel SPAD Technology

Alessia Suprano, Massimiliano Proietti, Francesco Poggiali +9 more

Low-light-level imaging in the infrared regime could find applications in areas ranging from technological to biological. Still, its development is limited by the inefficiency of silicon-based detectors in this regime. Quantum Ghost Imaging (QGI) can address this limitation by allowing the separation of illumination and imaging [1]. This is accomplished by generating non-degenerate correlated photon pairs, whose infrared photon probes the object and is detected by an InGaAs bucket detector, while the spatial distribution of the visible one is collected by a single-photon sensitive silicon camera. Traditional QGI setups evaluate photon correlations through “heralding”, by triggering the camera upon idler detection and thus require an image-preserving delay-line, which limits their use for remote sensing [1]. In asynchronous QGI (aQGI) cameras are replaced with SPAD arrays [2] able to record photon timestamp with picoseconds precision. By identifying pairs through timestamps comparison, the mentioned limitations are resolved [3], enabling applications with reflective or diffusive objects where the timestamp delay depends on the object's position. In this work, we propose and demonstrate an experimental QGI setup for remote sensing in reflection configuration (Fig. 1). Collinear non-degenerate pairs of single-photons at 550 nm and 1550 nm are generated by pumping a 2 mm-long type-0 ppKTP crystal with a 405 nm laser. To enable imaging of objects at varying distances, we implemented a momentum-correlation-based setup. Infrared photons interacting with the object were collected by commercially available InGaAs SPAD detectors, while the visible photons were directly captured using a prototype silicon SPAD array developed by Politecnico di Milano [4]. It is based on a 32×32 SPAD, with in-pixel TDCs, and on-chip microlenses are employed to reach a fill factor of 78%. The time resolution is adjustable down to 250 ps, with 1 μs Full Scale Range (FSR). The measurement duty cycle (i.e. the ration of the TDC FSR and the frame time) can be increased with a multi-gate acquisition scheme. To validate the efficiency of our setup, we tested it using a proof-of-principle object, as shown in Fig. 1b. The reconstructed images, captured with the object placed at 30 cm intervals in an acquisition time of only 30 s, are shown in Fig. 1c. In summary, the shown results confirm the potential of the proposed setup for remote sensing applications, particularly for reflective or diffusive objects. Moreover, the proposed approach could offers the possibility of significantly reduce acquisition times compared to standard QGI setups.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations

3D quantum ghost imaging

Carsten Pitsch, Dominik Walter, Helge Bürsing +1 more

Quantum Ghost Imaging (QGI) is a scheme which uses the temporal correlation of entangled photon pairs (signal and idler) to identify detections belonging to actual entangled pairs and separate them from uncorrelated detections. By also exploiting the spatial correlation of the photon pair, this identification allows to extract image information of the idler photons by imaging the signal photons. This can even be done for non-degenerate photon pairs, allowing imaging at wavelengths without sophisticated cameras in this regime. Recent advances in detector technology, especially single photon avalanche diodes (SPADs), allow the design for new cameras capable of single photon detection with both high spatial and temporal resolution. These new detectors are especially useful for application in QGI, allowing to detect each photon individually and identify the correlated pairs after the measurement. It further allows to analyse the time-of-flight of photons and thus enables 3D imaging, the first realization of which will be presented here.

Emerging Imaging and Sensing Technologies for Security and Defence•Oct 17, 2023•1 citation

Heralded single-photon ghost imaging

Reuben S. Aspden, D. S. Tasca, Robert W. Boyd +1 more

Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.

•Dec 20, 2012•1 citation
Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.
Quantum Ghost Imaging (QGI) is a powerful imaging technique that enables probing of an object using illumination levels beyond classical limits and does not rely on a single-photon-sensitive camera in the spectrum of interest. Current “heralded” QGI setups provide high-resolution images with intensified charge-coupled device (ICCD) cameras, but their acquisition time and applicability are limited by setup complexity and detector dead time. Recently, new setups using single photon detection and time-tagging have been shown to allow more efficient acquisition while also enabling new applications, such as remote 3D imaging using “asynchronous” QGI. Here, we demonstrate novel results of two asynchronous QGI setups, using a dedicated high duty-cycle single photon avalanche diode array to drastically reduce acquisition time to sub-second regime, demonstrating video acquisition at 10 fps. As this scheme allows interoperability with arbitrary single photon timing detectors, it can be adapted to a variety of applications and is not bound by the detection window of silicon-based detectors. We further study the impact of the choice of bucket detector and pump laser, using readily available off-the-shelf detectors and lasers. Summarizing the findings, we discuss the remaining limitations for real-time imaging and give an outlook on upcoming developments and an outline of further applications of both detectors and detection scheme.
Quantum Ghost Imaging (QGI) is an intriguing imaging protocol that exploits photon-pair correlations stemming from spontaneous parametric down-conversion (SPDC). QGI retrieves images from two-path joint measurements, where single-path detection does not allow to reconstruct the target image. This technique, has been so far limited in terms of acquisition speed either by raster scanning, or by the slow electronics of intensified cameras. Here we report on a fast QGI implementation exploiting a SPAD array detector for the spatially resolving path, enabling the acquisition of a ghost image in under one minute. Moreover, the employment of non-degenerate SPDC allows to investigate samples at infrared wavelengths without the need for short-wave infrared (SWIR) cameras, while the spatial detection can be still performed in the visible region, where the more advanced silicon-based technology can be exploited. Our findings advance the state-of-the-art of QGI schemes towards practical applications.
Correlated photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments, two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated photon ghost imaging experiments have scanned a single-pixel detector through the field of view to obtain spatial information. However, scanning leads to poor sampling efficiency, which scales inversely with the number of pixels, N , in the image. In this work, we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far field of the photon pair source, taking advantage of the Einstein–Podolsky–Rosen-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.
Low-light-level imaging in the infrared regime could find applications in areas ranging from technological to biological. Still, its development is limited by the inefficiency of silicon-based detectors in this regime. Quantum Ghost Imaging (QGI) can address this limitation by allowing the separation of illumination and imaging [1]. This is accomplished by generating non-degenerate correlated photon pairs, whose infrared photon probes the object and is detected by an InGaAs bucket detector, while the spatial distribution of the visible one is collected by a single-photon sensitive silicon camera. Traditional QGI setups evaluate photon correlations through “heralding”, by triggering the camera upon idler detection and thus require an image-preserving delay-line, which limits their use for remote sensing [1]. In asynchronous QGI (aQGI) cameras are replaced with SPAD arrays [2] able to record photon timestamp with picoseconds precision. By identifying pairs through timestamps comparison, the mentioned limitations are resolved [3], enabling applications with reflective or diffusive objects where the timestamp delay depends on the object's position. In this work, we propose and demonstrate an experimental QGI setup for remote sensing in reflection configuration (Fig. 1). Collinear non-degenerate pairs of single-photons at 550 nm and 1550 nm are generated by pumping a 2 mm-long type-0 ppKTP crystal with a 405 nm laser. To enable imaging of objects at varying distances, we implemented a momentum-correlation-based setup. Infrared photons interacting with the object were collected by commercially available InGaAs SPAD detectors, while the visible photons were directly captured using a prototype silicon SPAD array developed by Politecnico di Milano [4]. It is based on a 32×32 SPAD, with in-pixel TDCs, and on-chip microlenses are employed to reach a fill factor of 78%. The time resolution is adjustable down to 250 ps, with 1 μs Full Scale Range (FSR). The measurement duty cycle (i.e. the ration of the TDC FSR and the frame time) can be increased with a multi-gate acquisition scheme. To validate the efficiency of our setup, we tested it using a proof-of-principle object, as shown in Fig. 1b. The reconstructed images, captured with the object placed at 30 cm intervals in an acquisition time of only 30 s, are shown in Fig. 1c. In summary, the shown results confirm the potential of the proposed setup for remote sensing applications, particularly for reflective or diffusive objects. Moreover, the proposed approach could offers the possibility of significantly reduce acquisition times compared to standard QGI setups.
Quantum Ghost Imaging (QGI) is a scheme which uses the temporal correlation of entangled photon pairs (signal and idler) to identify detections belonging to actual entangled pairs and separate them from uncorrelated detections. By also exploiting the spatial correlation of the photon pair, this identification allows to extract image information of the idler photons by imaging the signal photons. This can even be done for non-degenerate photon pairs, allowing imaging at wavelengths without sophisticated cameras in this regime. Recent advances in detector technology, especially single photon avalanche diodes (SPADs), allow the design for new cameras capable of single photon detection with both high spatial and temporal resolution. These new detectors are especially useful for application in QGI, allowing to detect each photon individually and identify the correlated pairs after the measurement. It further allows to analyse the time-of-flight of photons and thus enables 3D imaging, the first realization of which will be presented here.
Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.