Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Physics

High-precision measurement of the magneto-optical Faraday effect via difference weak measurements

Zhihui Wang, Bo Wang, Xuan Zheng, Liza Jiensibieke, Junpeng Wang, Sujian Niu, Zhaoxue Li, Xining Yang

Published Nov 19, 2024• 2 citations
Publisher

Abstract

We propose a modified difference weak measurement scheme that permits precise measurements of the magneto-optical Faraday effect. By making normalized difference processing for a set of post-selected light intensity, a linear-response regime with a significant weak-value amplification effect is established. In the proof-of-principle experiment, we measure the magnetic intensity using the polarization system and achieve precision at the order of ∼10−7 T. Our scheme can be applied to measure other magneto-optical effects, providing a method for future ultra-sensitive sensing and metrology in magnetic physics.

DOI
10.1063/5.0237258

Related papers

Weak-value technique for detecting weak magnetic field based on Faraday magneto-optic effect

Jing-Hui Huang, Xue-Ying Duan, Guangjun Wang +1 more

We study the amplification of weak magnetic field with Weak-value technique based on Faraday magneto-optic effect. By using a different scheme to perform the Sagnac interferometer with the probe in momentum space, we have demonstrated the new weak measure protocol to detect the small weak magnetic field by amplifying the phase shift of Faraday magneto-optic effect. At the given the maximum incident intensity of the initial spectrum, the detection limit of the intensity of the spectrometer and the accuracy of detecting weak magnetic field, we can theoretically give the appropriate pre-selection, post-selection and others optical structure before experiment. Our numerical results show our scheme with Weak-value technique is effective and feasible to detect weak magnetic field with magnetic field intensity lower than $10^{-10}$ T.

arXiv:2105.13638•May 28, 2021•1 citation

Enhancing the precision of detecting weak magnetic fields based on weak-value amplification

Jing-Hui Huang, Xue-Ying Duan, Guangjun Wang +1 more

We study the amplification of a weak magnetic field with the weak-value amplification (WVA) technique based on the Faraday magneto-optic effect. By using a different scheme to perform the Mach–Zehnder interferometer with the probe in momentum space, we have demonstrated a new, to the best of our knowledge, weak measure protocol to detect the small weak magnetic field by amplifying the phase shift of the Faraday magneto-optic effect. Our numerical results show that our scheme with the WVA technique has a higher signal-to-noise ratio than the traditional optical fiber scheme with the open-loop modulation technique. Besides, considering the instrument limitations of our scheme, we have demonstrated the magnetic field resolution at the 10 − 13 T level.

Journal of the Optical Society of America B•Mar 21, 2022•13 citations

Simultaneously precise estimations of phase and amplitude variations based on weak-value amplification

Lan E Luo, Linguo Xie, Jiangdong Qiu +6 more

In this paper, we theoretically and experimentally present a precision method to simultaneously estimate the phase and amplitude variations of light based on the weak-value amplification. We demonstrate that the imaginary and real components of the weak-value correspond to the amplification of the phase and amplitude variations, respectively. If both the phase and the amplitude are varied, the phase measurement using the imaginary weak-value is not influenced by the amplitude shift and the amplitude measurement using the real weak value is not influenced by the phase shift. Thus, the tiny changes of the phase and amplitude of light can be obtained simultaneously with different post-selections, and the measurement precision reaches ∼10−6 rad. These findings may be favorable for highly sensitive optical polarization-dependent effects, including optical activity and magneto-optic effects.

Applied Physics Letters•Mar 18, 2019•25 citations

Improving the Precision of Optical Metrology by Detecting Fewer Photons

Peng Yin, Wen-Hao Zhang, Liang Xu +13 more

In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number to improve measurement precision. However, practical constraints prevent arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to circumvent detector saturation effect with low-cost apparatuses.

arXiv:2103.12373•Mar 23, 2021•0 citations

Improving the precision of optical metrology by detecting fewer photons with biased weak measurement

Peng Yin, Wen-Hao Zhang, Liang Xu +13 more

In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number n to improve measurement precision. However, practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by the saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.

Light Science & Applications•May 17, 2021•43 citations

Simultaneous Measurement of Magneto-Optical Rotation and Ellipticity using Two-Pointer Weak Measurement

Tong Li, Yifan Wang, Lan Luo +2 more

Magneto-optical (MO) effects, manifested as a complex rotation of light polarization under an external magnetic field, are widely utilized in optical isolators, sensors, data storage, and magnetic imaging. Accurate measurement of both the rotation angle (the real part) and the ellipticity (the imaginary part) is essential for fundamental research and device applications. However, existing measurement schemes generally cannot determine these two quantities simultaneously within a single experimental process. In this work, we propose a scheme based on weak measurement using two pointers, enabling the simultaneous measurement of the rotation angle and ellipticity within a single meter state. This method was experimentally implemented to measure the magneto-optical Kerr effect under various configurations—longitudinal, polar, and transverse. Moreover, the proposed approach is also applicable to the measurement of the Faraday effect and magnetic linear birefringence, demonstrating its broad applicability. This work contributes to the advancement of high-precision measurement techniques for MO effects and supports their wider application across multiple fields.

•Jan 23, 2026•0 citations
We propose a modified difference weak measurement scheme that permits precise measurements of the magneto-optical Faraday effect. By making normalized difference processing for a set of post-selected light intensity, a linear-response regime with a significant weak-value amplification effect is established. In the proof-of-principle experiment, we measure the magnetic intensity using the polarization system and achieve precision at the order of ∼10−7 T. Our scheme can be applied to measure other magneto-optical effects, providing a method for future ultra-sensitive sensing and metrology in magnetic physics.
We study the amplification of weak magnetic field with Weak-value technique based on Faraday magneto-optic effect. By using a different scheme to perform the Sagnac interferometer with the probe in momentum space, we have demonstrated the new weak measure protocol to detect the small weak magnetic field by amplifying the phase shift of Faraday magneto-optic effect. At the given the maximum incident intensity of the initial spectrum, the detection limit of the intensity of the spectrometer and the accuracy of detecting weak magnetic field, we can theoretically give the appropriate pre-selection, post-selection and others optical structure before experiment. Our numerical results show our scheme with Weak-value technique is effective and feasible to detect weak magnetic field with magnetic field intensity lower than 10−1010^{-10}10−10 T.
We study the amplification of a weak magnetic field with the weak-value amplification (WVA) technique based on the Faraday magneto-optic effect. By using a different scheme to perform the Mach–Zehnder interferometer with the probe in momentum space, we have demonstrated a new, to the best of our knowledge, weak measure protocol to detect the small weak magnetic field by amplifying the phase shift of the Faraday magneto-optic effect. Our numerical results show that our scheme with the WVA technique has a higher signal-to-noise ratio than the traditional optical fiber scheme with the open-loop modulation technique. Besides, considering the instrument limitations of our scheme, we have demonstrated the magnetic field resolution at the 10 − 13 T level.
In this paper, we theoretically and experimentally present a precision method to simultaneously estimate the phase and amplitude variations of light based on the weak-value amplification. We demonstrate that the imaginary and real components of the weak-value correspond to the amplification of the phase and amplitude variations, respectively. If both the phase and the amplitude are varied, the phase measurement using the imaginary weak-value is not influenced by the amplitude shift and the amplitude measurement using the real weak value is not influenced by the phase shift. Thus, the tiny changes of the phase and amplitude of light can be obtained simultaneously with different post-selections, and the measurement precision reaches ∼10−6 rad. These findings may be favorable for highly sensitive optical polarization-dependent effects, including optical activity and magneto-optic effects.
In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number to improve measurement precision. However, practical constraints prevent arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to circumvent detector saturation effect with low-cost apparatuses.
In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number n to improve measurement precision. However, practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by the saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.
Magneto-optical (MO) effects, manifested as a complex rotation of light polarization under an external magnetic field, are widely utilized in optical isolators, sensors, data storage, and magnetic imaging. Accurate measurement of both the rotation angle (the real part) and the ellipticity (the imaginary part) is essential for fundamental research and device applications. However, existing measurement schemes generally cannot determine these two quantities simultaneously within a single experimental process. In this work, we propose a scheme based on weak measurement using two pointers, enabling the simultaneous measurement of the rotation angle and ellipticity within a single meter state. This method was experimentally implemented to measure the magneto-optical Kerr effect under various configurations—longitudinal, polar, and transverse. Moreover, the proposed approach is also applicable to the measurement of the Faraday effect and magnetic linear birefringence, demonstrating its broad applicability. This work contributes to the advancement of high-precision measurement techniques for MO effects and supports their wider application across multiple fields.