Physical Review Research

Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons

Juan M. Cornejo, Johannes Brombacher, Julia A. Coenders, Moritz von Boehn, Teresa Meiners, Malte Niemann, S. Ulmer, C. Ospelkaus

Published Sep 3, 2024• 10 citations
Publisher

Abstract

Manipulating the motion of individual trapped ions at the single quantum level has become standard practice in radio-frequency ion traps, enabling sweeping advances in quantum information processing and precision metrology. The key step for motional-state engineering is ground-state cooling. Full motional control also bears great potential to explore another regime of sensitivities for fundamental physics tests in Penning traps. Here we demonstrate the key enabling step by implementing resolved-sideband cooling on the axial mode of a single Be + 9 ion in a 5 Tesla cryogenic Penning trap. The system has been developed for the implementation of high-precision antimatter experiments to test the fundamental symmetries of the standard model with the highest accuracy in the baryonic sector. We measure an axial phonon number of n ¯ z = 0.10 ( 4 ) after cooling and demonstrate that the axial heating rate in our system is compatible with the implementation of quantum logic spectroscopy of (anti-)protons. Published by the American Physical Society 2024

DOI
10.1103/physrevresearch.6.033233

Related papers

Resolved-sideband cooling of a single $^9$Be$^+$ ion in a Penning trap

Cornejo, Juan M., Johannes Brombacher, Julia A. Coenders +5 more

Manipulating individual trapped ions at the single quantum level has become standard practice in radio-frequency ion traps, enabling applications from quantum information processing to precision metrology. The key ingredient is ground-state cooling of the particle's motion through resolved-sideband laser cooling. Ultra-high-presicion experiments using Penning ion traps will greatly benefit from the reduction of systematic errors offered by full motional control, with applications to atomic masses and $g$-factor measurements, determinations of fundamental constants or related tests of fundamental physics. In addition, it will allow to implement quantum logic spectroscopy, a technique that has enabled a new class of precision measurements in radio-frequency ion traps. Here we demonstrate resolved-sideband laser cooling of the axial motion of a single $^9$Be$^+$ ion in a cryogenic 5 Tesla Penning trap system using a two-photon stimulated-Raman process, reaching a mean phonon number of $\bar{n}_z = 0.10(4)$. This is a fundamental step in the implementation of quantum logic spectroscopy for matter-antimatter comparison tests in the baryonic sector of the Standard Model and a key step towards improved precision experiments in Penning traps operating at the quantum limit.

arXiv:2310.18262•Oct 27, 2023•0 citations

Thermometry of 9Be+ ions in a cryogenic Penning trap

J. Mielke

High precision comparisons of the proton and antiproton g-factor enable stringent tests of CPT symmetry in the baryonic sector. However, current measurement routines suffer from long preparation times and high particle temperatures, which complicate the increase of the precision beyond the parts per billion regime. As a solution, new sympathetic cooling schemes based on co-trapped laser-cooled ions may be used to cool (anti-)protons to the ground state of motion and to significantly decrease particle preparation times. In addition, motional coupling to an auxiliary ion in a double-well potential can be used for the implementation of new readout schemes based on quantum logic spectroscopy for the spin-state of the (anti-)protons. This thesis describes a cryogenic Penning trap system for ground state cooling of single 9Be+ ions, which represents the latest development of the BASE experiment in Hannover towards the implementation of sympathetic cooling schemes and quantum logic spectroscopy of single (anti-)protons. Furthermore, the setup and implementation of lasers systems at 313nm for Doppler cooling, repumping and Raman interactions are described. To this end, an optical platform for laser beam delivery to the vacuum system and an optical phase-locked loop for the stabilization of the relative phase of two lasers at 313 nm are presented. In this work, the laser systems are used for measurements of the optical resonance frequencies for cooling, probing and repumping of 9Be+ ions. In addition, stimulated Raman transitions are demonstrated using two phase-locked lasers at 313nm. In the following, this technique is used for high-precision measurements of the qubit frequency and the magnetic field, as well as themometry measurements with 9Be+ ions. The temperature of the ions after Doppler cooling is measured as a function of the cooling laser parameters and a minimal axial mode temperature of 1.77(10) mK is obtained. The results of this thesis pave the way for sideband spectroscopy and ground state cooling of single 9Be+ ions in Penning traps, which is an essential prerequisite for sympathetic ground state cooling of single (anti-)protons and the application of quantum logic spectroscopy to (anti-)proton g-factor measurements in the future.

•Jan 1, 2021•0 citations

Optical stimulated-Raman sideband spectroscopy of a single $^9$Be$^+$ ion in a Penning trap

Cornejo, J. M., Johannes Brombacher, Julia A. Coenders +5 more

We demonstrate optical sideband spectroscopy of a single $^9$Be$^+$ ion in a cryogenic 5 Tesla Penning trap using two-photon stimulated-Raman transitions between the two Zeeman sublevels of the $1s^{2}2s$ ground state manifold. By applying two complementary coupling schemes, we accurately measure Raman resonances with and without contributions from motional sidebands. From the latter we obtain an axial sideband spectrum with an effective mode temperature of (3.1 $\pm$ 0.4)~mK. This results are a key step for quantum logic operations in Pennings traps, applicable to high precision matter-antimatter comparisons tests in the baryonic sector of the standard model.

arXiv:2308.09362•Aug 18, 2023•0 citations

Full Single-Quantum Control of Particles in Penning Traps for Symmetry Tests at the Quantum Limit

J. M. Cornejo, J. -A. Coenders, A. Lissel +9 more

The BASE collaboration aims to measure antimatter systems with the highest precision in order to perform a rigorous test of CPT symmetry and search for physics beyond the Standard Model. As part of the BASE collaboration, we pursue the development of quantum logic inspired cooling and detection techniques for g-factor measurements of (anti-)protons. Implementing these methods requires full quantum-level control of individual antimatter particles confined in cryogenic Penning traps. By mapping the (anti-)proton's internal state onto a co-trapped 9Be+ "logic" ion via free Coulomb coupling in a double-well potential, we can accelerate measurement cycles and push g-factor precision measurements on (anti-)protons toward the quantum limit. Here, we present an overview of the proposed method and the current status of the project, with special emphasis on the new cryogenic multi-Penning-trap stack and the proton detection system.

physics.atom-phCross-listedarXiv:2602.22802•Feb 27, 2026

Cryogenic 9Be+ Penning trap for precision measurements with (anti-)protons

M Niemann, T Meiners, J Mielke +4 more

Abstract Cooling and detection schemes using laser cooling and methods of quantum logic can contribute to high precision CPT symmetry tests in the baryonic sector. This work introduces an experiment to sympathetically cool protons and antiprotons using the Coulomb interaction with a ion trapped in a nearby but separate potential well. We have designed and set up an apparatus to show such coupling between two identical ions for the first time in a Penning trap. In this paper, we present evidence for successful loading and Doppler cooling of clouds and single ions. Our coupling scheme has applications in a range of high-precision measurements in Penning traps and has the potential to substantially improve motional control in these experiments.

arXiv:1906.09249•Measurement Science and Technology•Nov 13, 2019•31 citations

Fast adiabatic transport of single laser-cooled 9Be+ ions in a cryogenic Penning trap stack

Teresa Meiners, Julia A. Coenders, Johannes Brombacher +4 more

Abstract High precision mass and g-factor measurements in Penning traps have enabled groundbreaking tests of fundamental physics. The most advanced setups use multi-trap methods, which employ transport of particles between specialized trap zones. Present developments focused on the implementation of sympathetic laser cooling will enable significantly shorter duty cycles and better accuracies in many of these scenarios. To take full advantage of these increased capabilities, we implement fast adiabatic transport concepts developed in the context of trapped-ion quantum information processing in a cryogenic Penning trap system. We show adiabatic transport of a single $$^9\textrm{Be}^+$$ 9 Be + ion initially cooled to 2 mK over a 2.2-cm distance within 15 ms and with less than 10 mK energy gain at a peak velocity of 3 m/s. These results represent an important step towards the implementation of quantum logic spectroscopy in the (anti-)proton system. Applying these developments to other multi-trap systems has the potential to considerably increase the data-sampling rate in these experiments.

The European Physical Journal Plus•Mar 15, 2024•3 citations
Manipulating the motion of individual trapped ions at the single quantum level has become standard practice in radio-frequency ion traps, enabling sweeping advances in quantum information processing and precision metrology. The key step for motional-state engineering is ground-state cooling. Full motional control also bears great potential to explore another regime of sensitivities for fundamental physics tests in Penning traps. Here we demonstrate the key enabling step by implementing resolved-sideband cooling on the axial mode of a single Be + 9 ion in a 5 Tesla cryogenic Penning trap. The system has been developed for the implementation of high-precision antimatter experiments to test the fundamental symmetries of the standard model with the highest accuracy in the baryonic sector. We measure an axial phonon number of n ¯ z = 0.10 ( 4 ) after cooling and demonstrate that the axial heating rate in our system is compatible with the implementation of quantum logic spectroscopy of (anti-)protons. Published by the American Physical Society 2024
Resolved-sideband cooling of a single 9^99Be+^++ ion in a Penning trap
Manipulating individual trapped ions at the single quantum level has become standard practice in radio-frequency ion traps, enabling applications from quantum information processing to precision metrology. The key ingredient is ground-state cooling of the particle's motion through resolved-sideband laser cooling. Ultra-high-presicion experiments using Penning ion traps will greatly benefit from the reduction of systematic errors offered by full motional control, with applications to atomic masses and ggg-factor measurements, determinations of fundamental constants or related tests of fundamental physics. In addition, it will allow to implement quantum logic spectroscopy, a technique that has enabled a new class of precision measurements in radio-frequency ion traps. Here we demonstrate resolved-sideband laser cooling of the axial motion of a single 9^99Be+^++ ion in a cryogenic 5 Tesla Penning trap system using a two-photon stimulated-Raman process, reaching a mean phonon number of nˉz=0.10(4)\bar{n}_z = 0.10(4)nˉz​=0.10(4). This is a fundamental step in the implementation of quantum logic spectroscopy for matter-antimatter comparison tests in the baryonic sector of the Standard Model and a key step towards improved precision experiments in Penning traps operating at the quantum limit.
High precision comparisons of the proton and antiproton g-factor enable stringent tests of CPT symmetry in the baryonic sector. However, current measurement routines suffer from long preparation times and high particle temperatures, which complicate the increase of the precision beyond the parts per billion regime. As a solution, new sympathetic cooling schemes based on co-trapped laser-cooled ions may be used to cool (anti-)protons to the ground state of motion and to significantly decrease particle preparation times. In addition, motional coupling to an auxiliary ion in a double-well potential can be used for the implementation of new readout schemes based on quantum logic spectroscopy for the spin-state of the (anti-)protons. This thesis describes a cryogenic Penning trap system for ground state cooling of single 9Be+ ions, which represents the latest development of the BASE experiment in Hannover towards the implementation of sympathetic cooling schemes and quantum logic spectroscopy of single (anti-)protons. Furthermore, the setup and implementation of lasers systems at 313nm for Doppler cooling, repumping and Raman interactions are described. To this end, an optical platform for laser beam delivery to the vacuum system and an optical phase-locked loop for the stabilization of the relative phase of two lasers at 313 nm are presented. In this work, the laser systems are used for measurements of the optical resonance frequencies for cooling, probing and repumping of 9Be+ ions. In addition, stimulated Raman transitions are demonstrated using two phase-locked lasers at 313nm. In the following, this technique is used for high-precision measurements of the qubit frequency and the magnetic field, as well as themometry measurements with 9Be+ ions. The temperature of the ions after Doppler cooling is measured as a function of the cooling laser parameters and a minimal axial mode temperature of 1.77(10) mK is obtained. The results of this thesis pave the way for sideband spectroscopy and ground state cooling of single 9Be+ ions in Penning traps, which is an essential prerequisite for sympathetic ground state cooling of single (anti-)protons and the application of quantum logic spectroscopy to (anti-)proton g-factor measurements in the future.
Optical stimulated-Raman sideband spectroscopy of a single 9^99Be+^++ ion in a Penning trap
We demonstrate optical sideband spectroscopy of a single 9^99Be+^++ ion in a cryogenic 5 Tesla Penning trap using two-photon stimulated-Raman transitions between the two Zeeman sublevels of the 1s22s1s^{2}2s1s22s ground state manifold. By applying two complementary coupling schemes, we accurately measure Raman resonances with and without contributions from motional sidebands. From the latter we obtain an axial sideband spectrum with an effective mode temperature of (3.1 ±\pm± 0.4)~mK. This results are a key step for quantum logic operations in Pennings traps, applicable to high precision matter-antimatter comparisons tests in the baryonic sector of the standard model.
The BASE collaboration aims to measure antimatter systems with the highest precision in order to perform a rigorous test of CPT symmetry and search for physics beyond the Standard Model. As part of the BASE collaboration, we pursue the development of quantum logic inspired cooling and detection techniques for g-factor measurements of (anti-)protons. Implementing these methods requires full quantum-level control of individual antimatter particles confined in cryogenic Penning traps. By mapping the (anti-)proton's internal state onto a co-trapped 9Be+ "logic" ion via free Coulomb coupling in a double-well potential, we can accelerate measurement cycles and push g-factor precision measurements on (anti-)protons toward the quantum limit. Here, we present an overview of the proposed method and the current status of the project, with special emphasis on the new cryogenic multi-Penning-trap stack and the proton detection system.
Abstract Cooling and detection schemes using laser cooling and methods of quantum logic can contribute to high precision CPT symmetry tests in the baryonic sector. This work introduces an experiment to sympathetically cool protons and antiprotons using the Coulomb interaction with a ion trapped in a nearby but separate potential well. We have designed and set up an apparatus to show such coupling between two identical ions for the first time in a Penning trap. In this paper, we present evidence for successful loading and Doppler cooling of clouds and single ions. Our coupling scheme has applications in a range of high-precision measurements in Penning traps and has the potential to substantially improve motional control in these experiments.
Abstract High precision mass and g-factor measurements in Penning traps have enabled groundbreaking tests of fundamental physics. The most advanced setups use multi-trap methods, which employ transport of particles between specialized trap zones. Present developments focused on the implementation of sympathetic laser cooling will enable significantly shorter duty cycles and better accuracies in many of these scenarios. To take full advantage of these increased capabilities, we implement fast adiabatic transport concepts developed in the context of trapped-ion quantum information processing in a cryogenic Penning trap system. We show adiabatic transport of a single 9Be+^9\textrm{Be}^+9Be+ 9 Be + ion initially cooled to 2 mK over a 2.2-cm distance within 15 ms and with less than 10 mK energy gain at a peak velocity of 3 m/s. These results represent an important step towards the implementation of quantum logic spectroscopy in the (anti-)proton system. Applying these developments to other multi-trap systems has the potential to considerably increase the data-sampling rate in these experiments.