Conference on Precision Electromagnetic Measurements
Next generation Programmable Quantum Current Generator
Sophie Djordjevic, Ralf Behr, W. Poirier
Abstract
This paper describes the latest improvements of the programmable quantum current generator (PQCG), which allow to get rid of the former 10−7relative corrections due to the resistance of the cable and extend the realization of the ampere over a wider current range, down to the µA range. Here we report on the first results of accuracy tests at 46 µA with a measurement uncertainty of one part in 108.