Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics

Sensing Magnetic Fields with an Array of Single Atoms

Andrea Parlangeli

Published Jun 4, 2024• 0 citations
Publisher

Abstract

Sensing Magnetic
DOI
10.1103/physics.17.92

Related papers

Quantum Sensing of Magnetic Fields

Anonymous

Physics•Jul 25, 2017•0 citations

Quantum Sensing in Tweezer Arrays: Optical Magnetometry on an Individual-Atom Sensor Grid

Dominik Schäffner, Tobias Schreiber, Fabian Lenz +2 more

We implement a scalable platform for quantum sensing comprising hundreds of sites capable of holding individual laser-cooled atoms and demonstrate the applicability of this single-quantum-system sensor array to magnetic-field mapping on a two-dimensional grid. With each atom being confined in an optical tweezer within an area of 0.5 micrometer^2 at mutual separations of 7.0(2) micrometer, we obtain micrometer-scale spatial resolution and highly parallelized operation. An additional steerable optical tweezer allows for a rearrangement of atoms within the grid and enables single-atom scanning microscopy with sub-micron resolution. This individual-atom sensor platform finds its immediate application in mapping an externally applied DC gradient magnetic field. In a Ramsey-type measurement, we obtain a field resolution of 98(29) nanotesla. We estimate the sensitivity to 25 microtesla/Hz^1/2.

arXiv:2307.08055•Jul 16, 2023•1 citation

Ultrasensitive magnetic field detection using a single artificial atom

Mustafa Bal, C. Deng, Jean-Luc Orgiazzi +2 more

arXiv:1301.0778•Nature Communications•Dec 21, 2012•91 citations

Quantum Sensing in Tweezer Arrays: Optical Magnetometry on an Individual-Atom Sensor Grid

Dominik Schäffner, Tobias Schreiber, Fabian Lenz +2 more

We implement a scalable platform for quantum sensing comprising hundreds of sites capable of holding individual laser-cooled atoms and demonstrate the applicability of this single-quantum-system sensor array to magnetic field mapping on a two-dimensional grid. With each atom being confined in an optical tweezer within an area of 0.5 μ m 2 at mutual separations of 7.0 ( 2 ) μ m , we obtain micrometer-scale spatial resolution and highly parallelized operation. An additional steerable optical tweezer allows rearrangement of atoms within the grid and enables single-atom scanning microscopy with submicron resolution. This individual-atom sensor platform finds an immediate application in mapping an externally applied dc gradient magnetic field. In a Ramsey-type measurement, we obtain a field resolution of 98(29) nT. We estimate the sensitivity to be 25 μ T / Hz . Published by the American Physical Society 2024

PRX Quantum•Jan 26, 2024•32 citations

Ultracompact and Highly Sensitive Atomic Magnetometer Array via a Polarization Volume Grating-Based Waveguide Structure

Yuzhuo Pei, Chuang Wang, Jing Qin +7 more

Ultraweak magnetic field measurement, as one of the quantum precision measurement techniques, holds important significance in the forefront of explorations in physics and advanced medical technologies. The atomic magnetometer, serving as a typical instrument for measuring extremely weak magnetic fields, utilizes the Larmor precession frequency of electrons in alkali metal atoms to quantify magnetic field magnitudes at subfemtotesla levels. Additionally, atomic magnetometers boast advantages such as high sensitivity, miniaturization and high spatial resolution. Hence, arrays of atomic magnetometer sensors have become a reliable solution for measuring ultraweak magnetic fields in spatial dimensions. This paper proposes an ultracompact and highly sensitive atomic magnetometer array integrated structure via a highly stable polarization volume grating (PVG)-based waveguide structure for beam splitting. Instead of the traditional four polarizing beam splitters and polarizors, the structure integrates parallel beam splitting and polarization conversion functions using PVGs, which are then incorporated into an ultracompact atomic magnetometer array. This integration enables high sensitivity magnetic field measurements in four channels. The light separated by the structure exhibits power fluctuations along a single polarization axis below 0.2% during a 30 min period. The overall volume of the proposed integrated structure is approximately 0.6 cm 3, representing at least an order of magnitude reduction compared to other spatial optical atomic magnetometer array structures. The final validation demonstrates the system can measure magnetic fields on the order of femtotesla, with an average sensitivity of 16.1 fT/Hz 1/2 . This approach holds significant potential for applications in quantum precision sensing, high resolution medical imaging, and biological science exploration.

ACS Photonics•Feb 19, 2025•6 citations

Atoms in magnetic fields

Paul Ewart

Morgan & Claypool Publishers eBooks•Feb 1, 2019•0 citations
We implement a scalable platform for quantum sensing comprising hundreds of sites capable of holding individual laser-cooled atoms and demonstrate the applicability of this single-quantum-system sensor array to magnetic-field mapping on a two-dimensional grid. With each atom being confined in an optical tweezer within an area of 0.5 micrometer^2 at mutual separations of 7.0(2) micrometer, we obtain micrometer-scale spatial resolution and highly parallelized operation. An additional steerable optical tweezer allows for a rearrangement of atoms within the grid and enables single-atom scanning microscopy with sub-micron resolution. This individual-atom sensor platform finds its immediate application in mapping an externally applied DC gradient magnetic field. In a Ramsey-type measurement, we obtain a field resolution of 98(29) nanotesla. We estimate the sensitivity to 25 microtesla/Hz^1/2.
We implement a scalable platform for quantum sensing comprising hundreds of sites capable of holding individual laser-cooled atoms and demonstrate the applicability of this single-quantum-system sensor array to magnetic field mapping on a two-dimensional grid. With each atom being confined in an optical tweezer within an area of 0.5 μ m 2 at mutual separations of 7.0 ( 2 ) μ m , we obtain micrometer-scale spatial resolution and highly parallelized operation. An additional steerable optical tweezer allows rearrangement of atoms within the grid and enables single-atom scanning microscopy with submicron resolution. This individual-atom sensor platform finds an immediate application in mapping an externally applied dc gradient magnetic field. In a Ramsey-type measurement, we obtain a field resolution of 98(29) nT. We estimate the sensitivity to be 25 μ T / Hz . Published by the American Physical Society 2024
Ultraweak magnetic field measurement, as one of the quantum precision measurement techniques, holds important significance in the forefront of explorations in physics and advanced medical technologies. The atomic magnetometer, serving as a typical instrument for measuring extremely weak magnetic fields, utilizes the Larmor precession frequency of electrons in alkali metal atoms to quantify magnetic field magnitudes at subfemtotesla levels. Additionally, atomic magnetometers boast advantages such as high sensitivity, miniaturization and high spatial resolution. Hence, arrays of atomic magnetometer sensors have become a reliable solution for measuring ultraweak magnetic fields in spatial dimensions. This paper proposes an ultracompact and highly sensitive atomic magnetometer array integrated structure via a highly stable polarization volume grating (PVG)-based waveguide structure for beam splitting. Instead of the traditional four polarizing beam splitters and polarizors, the structure integrates parallel beam splitting and polarization conversion functions using PVGs, which are then incorporated into an ultracompact atomic magnetometer array. This integration enables high sensitivity magnetic field measurements in four channels. The light separated by the structure exhibits power fluctuations along a single polarization axis below 0.2% during a 30 min period. The overall volume of the proposed integrated structure is approximately 0.6 cm 3, representing at least an order of magnitude reduction compared to other spatial optical atomic magnetometer array structures. The final validation demonstrates the system can measure magnetic fields on the order of femtotesla, with an average sensitivity of 16.1 fT/Hz 1/2 . This approach holds significant potential for applications in quantum precision sensing, high resolution medical imaging, and biological science exploration.