The calibration method based on correlated photons can realize absolute calibration without standard transfer. The solar spectral irradiance meter using this calibration method needs a correlated photon source with a broad spectrum to achieve absolute calibration in the solar reflection band. In the early stage, non-collinear phase matching combined with multiple crystals was generally adopted to achieve wide spectral coverage. In this paper, a continuous wide spectral correlated photon source is obtained using pumping a BBO crystal by a 532nm laser and continuous angle tuning collinear phase matching. The collinear phase matching positions at different wavelengths are determined by the rotation crystal which shrinks the relevant photon rings into circular spots. The spectral range and correlation of the broad spectral correlated photon source are verified by the correlated photon ring image and the coincidence counting of four pairs of correlated photons of 800nm/1580nm, 840nm/1450nm, 900 nm/ 1300nm, and 950nm/1200nm.
The calibration method based on correlated photons can realize absolute calibration without standard transfer. The solar spectral irradiance meter using this calibration method needs a correlated photon source with a broad spectrum to achieve absolute calibration in the solar reflection band. In the early stage, non-collinear phase matching combined with multiple crystals was generally adopted to achieve wide spectral coverage. In this paper, a continuous wide spectral correlated photon source is obtained using pumping a BBO crystal by a 532nm laser and continuous angle tuning collinear phase matching. The collinear phase matching positions at different wavelengths are determined by the rotation crystal which shrinks the relevant photon rings into circular spots. The spectral range and correlation of the broad spectral correlated photon source are verified by the correlated photon ring image and the coincidence counting of four pairs of correlated photons of 800nm/1580nm, 840nm/1450nm, 900 nm/ 1300nm, and 950nm/1200nm.
The correlated photon technique makes it possible to achieve a radiation calibration processing without chain transferring. The study of the spectral radiation character and time correlation of the photon is of great significance for broad-band radiometric calibration. To absolutely calibrate quantum efficiency of photoelectric detector, it is necessary to extend calibration band from single band to more bands. According to the phase-matching condition of the spontaneous parametric down-conversion, non-collinear angle formula of correlated photon in the crystal is derived. The distribution of the photon spectrum is simulated. Meanwhile, the phase-matching angle of the crystal is optimized. The photon generated by the spontaneous parameters down-conversion has a broad spectral distribution and the correlated photon wavelength is corresponding to its emission angle. Based on the result of the simulation, the experimental measurement system of the spectral distribution and time-correlation of the correlated photon is established. The spectral distribution, the time-correlation and the polarization properties of the four pair photon were measured by using this system. The experimental results show that, (1) the spectral distribution of the measurements is 633~808 nm, where the maximum spectral distribution measurement bias is 1.51 mm. The experiment result is highly consistent with theoretical ones; (2) the correlation time of four pairs correlated photon is measured, during which “three coincidence-peaks” is observed and the minimum correlation time was 0.32 ns; (3) single photon count rate along with coincidence count rate of correlated photon vary with the polarization direction of the pump as sine function. The experimental result is shown that the correlated photon pairs are ranging from the visible to near infrared band distribution, and that the spectrum has time-correlation and polarization characteristic. The research result is firstly reported at home and abroad, and the results are promising for the application of the photoelectric detector in the multi-band radiometric calibration.
The high-precision self-calibration radiation reference source is currently the research focus of satellite remote sensing calibration. In order to meet the requirements of quantitative applications such as climate monitoring, low-light radiation metering and single photon source radiance measurement, in view of the application requirements and technical requirements of visible to near infrared low-light radiometer, a compact three-channel low-light radiance meter based on correlated photon self-calibration is designed. This design method can improve the measurement accuracy of low light irradiance by using objective physical effect instead of physical standard, reducing the cumulative error caused by standard transfer chain. The absolute calibration of the detector responsivity can be achieved by the spontaneous parameter down-conversion effect, and the absolute radiation observation can be achieved without relying on the external reference. Based on this study, combined with the special application requirements of radiance meter, a numerical model of spectral rate and geometric transmission characteristics of wide spectrum correlated photons is established, and two basic operating modes of self-calibration and radiation observation are determined. The interaction between 355 nm pump source and nonlinear medium generates three-wave mixing, and the correlated photons are generated by class I non-collinear spontaneous parametric downconversion, the combined effect of monochromatic pump photon flow and quantum vacuum noise on non-centrosymmetric nonlinear crystal makes each incident photon spontaneously split into two photons with lower energy with a certain probability, called signal photons and idle photons respectively, they have a wide sptrum distribution from pump wave frequency to lattice resonance frequency. Correlated photon source has the technical characteristics of time and space correlation, natural wide spectrum and absolute reproducibility, so it has high absolute accuracy. Integrated design of self-calibration and radiation observation can monitor and correct changes in response characteristics in real time, maintain long-term stability of response characteristics, and improve traceability and accuracy of observation data. This design method solve the key technologies such as preparation and value transfer of correlated photon sources, suppression of pump stray light, high precision and high efficiency coupling of correlated photons, UV radiation resistance of space single-photon detectors, packaging reinforcement technology of space single-photon detectors,self-calibration and integrated design of radiation observation. The spectral measurement range of the low-light radiance meter is from 460 nm to 1 550 nm, the measurement range of radiance is 1×10-9~1×10-6 W/(cm2·sr·nm). In the design, the integration, miniaturization and modularization of the whole system are considered, and the eight spectral bands are integrated into a three-channel structure, solving the preparation of wide spectrum dependent photon source, optical multiplexing of calibration optical path, radiation measurement, high precision coincidence measurement and full optical path calibration of radiance meter, and achieving high precision radiation observation from visible to near infrared and periodic self-calibration research targets. In the self-calibration mode, the multiplex optical path module periodically introduces the spontaneous parametric down-conversion correlated photons, and the photon counting and coincidence detection module are used to calibrate the absolute quantum efficiency of the three channels. In the radiation observation mode, the multiplex optical path module introduces the low-light level target radiation and obtains the absolute spectral radiance of the observation target in the band of 460~1 550 nm at the same time. The calibration coefficient obtained by the self-calibration mode is used to correct the observation results. The effects of link error limited by radiation reference value transfer, optical decay of optical path and electronic decay of optical path on the measurement accuracy of microradiance are fundamentally solved. The visible near-infrared band adopts free space coupling mode and the short-wave infrared band adopts multi-mode fiber coupling mode. Through design optimization analysis, the focusing spots of the first and second channels meet the 300 μm pixel requirement of Si single photon detector, and the focusing spot of the third channel meets the 62.5 μm core diameter and 0.22 numerical aperture requirement of multi-mode fiber, all of them can be received by the detector photosensitive surface, meeting the design objectives. The method based on correlated photon calibration does not need to trace the high-precision primary standard in the laboratory and the lengthy standard transfer chain. By using the correlated photon generated in the process of parametric down-conversion, the calibration source of time, space and polarization can be obtained, and the high-precision observation of the low-light spectrum radiance from visible to near infrared band can be realized. The solution to the scientific problem of low-light observation instrument in space platform measurement can obtain higher calibration accuracy, and play an important role in climate monitoring, low-light radiation metrology, single-photon source radiance measurement and so on.
In this paper, the spatial properties of correlated photon in collinear phase-matching in the process of spontaneous parametric down conversion (SPDC) are researched. Based on the study of the phase-matching angle, non-collinear angle, and correlated photon wavelength, a theoretical model of non-collinear angular variation is derived, which can be used to estimate and predict the width of the correlated photon ring. The experimental measurement is carried out with CMOS camera, and the measurement results are consistent with the theoretical simulation results, which verifies the rationality of theoretical reasoning. Meanwhile, the change of the correlated photon divergence angle outside the crystal is studied, the closer the wavelength is to the degenerate, the smaller the measurement value of the divergence angle, which is agreement with the theoretical simulation. The results of the study play a reference role in the evaluation of the spatial properties of correlated photon and lay a foundation for the measurement of the correlated photon number rate and the calibration of a photodetector.
Entangled photon pairs generated via spontaneous parametric down-conversion (SPDC) in beta-barium borate (BBO) crystals are fundamental to the realization of anchor-free quantum metrology and spaceborne radiometric standards. High-precision calibration strictly necessitates rigorous spectral and spatial matching of these entangled photons. However, the spatial distribution of entangled photons exhibits a profound dependence on the phase-matching angle. Due to the combined effects of crystal fabrication tolerances, environmental perturbations, and the extremely low intensity of entangled signals (∼pW level), conventional mono-dimensional angle tuning struggles to balance the conflicting requirements of spectral bandwidth and spatial distribution matching. To address this bottleneck, a synergistic tuning strategy integrating angle, temperature, and stress is proposed in this work. A multi-channel, high-precision temperature control system based on series-connected thermoelectric coolers (TECs) was developed, achieving a control precision superior to 0.01 ℃ at a setpoint of 50 ℃. By combining theoretical derivations with thermo-structural coupled simulations, the tuning regularities of temperature (30–70 ℃) and stress on the photon output angle were quantitatively characterized. Experimental measurements on the multi-channel BBO crystal configuration (comprising eight crystals) achieved a maximum tuning range (Δ θ OA ) of 2.941° and identified a non-destructive stress threshold of 312.5 N. This work elucidates the intrinsic mechanisms of temperature and stress in BBO phase-matching, providing critical engineering methodologies and theoretical underpinnings for enhancing quantum calibration accuracy while offering a paradigm for the multi-dimensional tuning of nonlinear optical crystals.
A new calibration method of detectors can be realized by using correlated photons generated in spontaneous parametric down-conversion (SPDC) effect of nonlinear crystal.An absolute calibration system of detector quantum efficiency is performed.And its principle and experimental setup are introduced.A continuouswave (CW) ultraviolet (351 nm), diode-pumped, frequency-doubled, and solid-state laser is used to pump BBO crystal.The quantum efficiencies of the photomultiplier at 633, 702, and 789 nm are measured respectively.The coincidence peaks are observed using coincidence circuit.Some measurement factors including the filter bandwidth of trigger channel, the detector position alignment and polarization of the pump light are analyzed.The uncertainties of this calibration method are also analyzed, and the relative uncertainties of total calibration are less than 5.8%.The accuracy of this method could be improved in the future.
A small, portable, high-flux correlated photon-pair source has been designed and constructed from simple opto-mechanical parts. Unique to this device is its straightforward alignment process, together with the direct coupling of signal and idler photons into polarization-maintaining single-mode optical fibers. Spontaneous parametric down-conversion is used to produce photon pairs in β-barium borate (BBO) at a center wavelength of 810 nm. Owing to the applied type-I phase-matching, coincident photons have identical polarization. The estimated fiber-coupling efficiency is 51%, the measured photon and coincidence flux are 636 and 130 kHz/mW, respectively, normalized to pump power (44 mW). The source has an extremely wide wavelength spectrum of 202-nm FWHM, measured at the fiber output, which limits the actual heralding ratio to 20%.