Phase distribution is crucial for obtaining the whole information of phase object in imaging. However, due to the transparency of phase objects, the phase distribution cannot be obtained in traditional bright-field imaging. Here, we propose a phase distribution reconstruction based on the imaginary value of weak measurement, which is achieved by a Pancharatnam–Berry phase metasurface. Moreover, by adjusting the weak value to a real weak value, amplitude reconstruction can also be achieved. Different parts of weak values can be obtained by controlling the preselection and postselection states. The weak interaction is achieved by the metasurface, which is convenient to control the weak coupling and reduce the complexity of the experimental setup at the same time. Furthermore, the edge contour of objects can also be acquired by the weak measurement, and the edge sharpness is related to types of the weak values, which plays an important role in image resolution. Our method paves a way for quantitative phase imaging and unlabeled biological imaging.
Phase distribution is crucial for obtaining the whole information of phase object in imaging. However, due to the transparency of phase objects, the phase distribution cannot be obtained in traditional bright-field imaging. Here, we propose a phase distribution reconstruction based on the imaginary value of weak measurement, which is achieved by a Pancharatnam–Berry phase metasurface. Moreover, by adjusting the weak value to a real weak value, amplitude reconstruction can also be achieved. Different parts of weak values can be obtained by controlling the preselection and postselection states. The weak interaction is achieved by the metasurface, which is convenient to control the weak coupling and reduce the complexity of the experimental setup at the same time. Furthermore, the edge contour of objects can also be acquired by the weak measurement, and the edge sharpness is related to types of the weak values, which plays an important role in image resolution. Our method paves a way for quantitative phase imaging and unlabeled biological imaging.
Edge information of images contains a variety of physical properties such as amplitude, phase, polarization, and frequency. These features usually correspond to the changes of the key structure of objects under measured. Therefore, edge imaging is of great significance in computer vision and optical detection. Here, we propose a controllable edge-enhanced imaging system with weak measurement, utilizing a Pancharatnam-Berry phase metasurface to achieve weak coupling between light and object. By setting the proper pre-selection state and post-selection state, high-contrast edge images are successfully obtained in demonstration experiments. Due to the utilization of metasurface, the proposed system significantly simplifies the complexity of traditional optical imaging methods while maintaining weak coupling controllability. Furthermore, by fine-tuning polarization states in measuring, the real and imaginary parts of the weak value can be flexibly adjusted. Therefore, a continuously adjustable observation between the edge-enhanced imaging mode and the complete imaging mode is achieved. This method provides a promising optical solution for multi-scale image detection.
In standard quantum weak measurements, preselection and postselection of quantum states are implemented in the same photon. Here we go beyond this restrictive setting and demonstrate that the preselection and postselection can be performed in two different photons, if the two photons are polarization entangled. The Pancharatnam-Berry phase metasurface is incorporated in the weak measurement system to perform weak coupling between probe wave function and spin observable. By introducing nonlocal weak measurement into the microscopy imaging system, it allows us to remotely switch different microscopy imaging modes of pure-phase objects, including bright-field, differential, and phase reconstruction. Furthermore, we demonstrate that the nonlocal weak-measurement scheme can prevent almost all environmental noise photons from detection and thus achieves a higher image contrast than the standard scheme at a low photon level. Our results provide the possibility to develop a quantum nonlocal weak-measurement microscope for label-free imaging of transparent biological samples.
The wave function is important for understanding and predicting the behavior of photons. Recent studies have shown that wave function can be reconstructed through weak measurement. But currently, the relationships of wave function, weak value, and probe are single and not complete. Here, we propose a wave function reconstruction method based on complex weak values and complex shift probes. Four relationships of them are built and the wave function can be reconstructed by position and momentum shift probes. The complex weak values can be obtained by adjusting the pre- and post-selection in weak measurement, while the complex shift probes originate from the complex nature of the Fresnel coefficient in total internal reflection. To demonstrate the feasibility of the proposed scheme, an experiment of phase distribution reconstruction is achieved by a real weak value and a momentum shift probe; the experimental results agree well with the theory and show a high contrast. Therefore, the wave function can be conveniently reconstructed by our scheme and the relationships between the wave function, weak values, and probes become more complete. This work provides a valuable reference for the application of weak measurement in image processing, quantitative phase imaging, and label-free biological imaging.
The wave function is the cornerstone of quantum mechanics, although it is still open to different interpretations. It has been shown that the amplitude and the phase of a wave function are manifested in the imaginary and real parts of the momentum weak value, respectively. Based on this, we develop a weak measurement scheme to reconstruct the wave function through measuring the momentum weak value. A proof-of-principle experiment is made to confirm the feasibility of our measurement scheme, in which the polarization states and the momentum of light are coupled. We believe the experimental protocol has the potential to be applied in diverse fields such as wave-front sensing, edge detection, and optical communication, and measurement of the momentum weak value may offer valuable insight to better understand quantum mechanics.
Phase contrast microscopy is essential in optical imaging, but traditional systems are bulky and limited by single-phase modulation, hindering visualization of complex specimens.Metasurfaces, with their subwavelength structures, offer compact integration and versatile light field control.Quantum imaging further enhances performance by leveraging nonclassical photon correlations to suppress classical noise, improve contrast, and enable multifunctional processing.Here, we report, a dual-mode bright-dark phase contrast imaging scheme enabled by quantum metasurface synergy.By combining polarization entanglement from quantum light sources with metasurface phase modulation, our method achieves highcontrast, adaptive bright-dark phase contrast imaging of transparent samples with arbitrary phase distributions under low-light conditions.Compared to classical weak light imaging, quantum illumination suppresses environmental noise at equivalent photon flux, improving the contrast from 0.22 to 0.81.Moreover, quantum polarization entanglement enables remote switching to ensure high-contrast imaging in at least one mode, supporting dynamic observation of biological cells with complex phase structures.This capability is especially valuable in scenarios where physical intervention is difficult, such as in miniaturized systems, in vivo platforms, or extreme environments.Overall, the proposed scheme offers an efficient noninvasive solution for biomedical imaging with strong potential in life science applications.
Phase reconstruction plays a pivotal role in biology, medical imaging, and wavefront sensing. However, multiple measurements and adjustments are usually required for conventional schemes, which inevitably reduces the quality of phase imaging. Here, based on multi-channel metasurface and quantum entanglement source, a simple and integrated quantum analog operation system is proposed to realize quantitative phase reconstruction with a high signal-to-noise ratio (SNR) under a low signal photon level. Without additional measurements and adjustments, four differential images necessary for the phase reconstruction are captured simultaneously. The non-local correlation of entangled photon pairs enables to remotely manipulate working modes of the system. Besides, the consistency of entangled photon pairs in time domain makes it possible to achieve a high SNR imaging by trigger detection. The results may potentially empower the application of metasurfaces in optical chip, wave function reconstruction, and label-free biology imaging.