Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Nature Electronics

Measuring qubits with thermometers

David Pahl, William D. Oliver

Published Apr 25, 2024• 0 citations
Publisher
DOI
10.1038/s41928-024-01153-9

Related papers

Single qubits as thermometers

Sania Jevtic, David S. Newman, Terry Rudolph +1 more

•Aug 29, 2014•1 citation

A Quantum Thermometer

Springer eBooks•Dec 12, 2005•0 citations

Recipe for a Quantum Thermometer

Tamela Maciel

Physics•Jun 5, 2015•0 citations

Localized Thermometry via Dayem Bridges Integrated on Superconducting Qubit Chips

Ella O. Lachman, Dave P. Pappas, Jayss Marshall +1 more

Accurate knowledge of the on-chip temperature is essential for understanding and optimizing the performance of superconducting qubits, yet direct thermometry at millikelvin temperatures remains challenging. While qubits themselves are sensitive to the temperature of their environment, other factors may affect the qubits` effective temperature, and using them as thermometers with any accuracy requires specialized measurement protocols and qubit designs, limiting their practicality for routine diagnostics and adding complex infrastructure to any hardware testing apparatus. Here we demonstrate a complementary on-chip thermometry method based on superconducting Dayem bridges that are integrated on the same chip as transmon qubits. By extracting the critical current of the Dayem bridge from I-V measurements, we obtain a local, quantitative measure of the chip temperature without the need for microwave calibration or qubit-specific control sequences. To demonstrate the utility of the Dayem bridges as thermometers, we fabricate them in-situ with qubits on the same chip, calibrate the Dayem bridge critical current as a function of temperature, and characterize its resolution and stability at cryogenic temperatures. We additionally perform simultaneous measurements of the Dayem bridge thermometer and qubit excited-state population, and show agreement over the relevant temperature range, validating the method against established qubit thermometry. Furthermore, we correlate the independently measured chip temperature with qubit energy relaxation and dephasing times, demonstrating the utility of this approach for diagnosing temperature-dependent decoherence mechanisms. These results establish integrated Dayem bridges as a simple, non-invasive, and scalable tool for cryogenic hardware development, and on chip thermometry in superconducting quantum circuits.

quant-pharXiv:2607.06670•Jul 9, 2026•0 citations

Simulating and Optimising Quantum Thermometry Using Single Photons

W. K. Tham, Hugo Ferretti, Arun Vellat Sadashivan +1 more

A classical thermometer typically works by exchanging energy with the system being measured until it comes to equilibrium, at which point the readout is related to the final energy state of the thermometer. A recent paper noted that with a quantum thermometer consisting of a single spin/qubit, temperature discrimination is better achieved at finite times rather than once equilibration is essentially complete. Furthermore, preparing a qubit thermometer in a state with quantum coherence instead of an incoherent one improves its sensitivity to temperature differences. Implementing a recent proposal for efficiently emulating an arbitrary quantum channel, we use the quantum polarisation state of individual photons as models of "single-qubit thermometers" which evolve for a certain time in contact with a thermal bath. We investigate the optimal thermometer states for temperature discrimination, and the optimal interaction times, confirming that there is a broad regime where quantum coherence provides a significant improvement. We also discuss the more practical question of thermometers composed of a finite number of spins/qubits (greater than one), and characterize the performance of an adaptive protocol for making optimal use of all the qubits.

arXiv:1609.01589•Scientific Reports•Dec 15, 2016•29 citations

Qubit Measurements

WORLD SCIENTIFIC eBooks•Oct 29, 2025•0 citations
Accurate knowledge of the on-chip temperature is essential for understanding and optimizing the performance of superconducting qubits, yet direct thermometry at millikelvin temperatures remains challenging. While qubits themselves are sensitive to the temperature of their environment, other factors may affect the qubits` effective temperature, and using them as thermometers with any accuracy requires specialized measurement protocols and qubit designs, limiting their practicality for routine diagnostics and adding complex infrastructure to any hardware testing apparatus. Here we demonstrate a complementary on-chip thermometry method based on superconducting Dayem bridges that are integrated on the same chip as transmon qubits. By extracting the critical current of the Dayem bridge from I-V measurements, we obtain a local, quantitative measure of the chip temperature without the need for microwave calibration or qubit-specific control sequences. To demonstrate the utility of the Dayem bridges as thermometers, we fabricate them in-situ with qubits on the same chip, calibrate the Dayem bridge critical current as a function of temperature, and characterize its resolution and stability at cryogenic temperatures. We additionally perform simultaneous measurements of the Dayem bridge thermometer and qubit excited-state population, and show agreement over the relevant temperature range, validating the method against established qubit thermometry. Furthermore, we correlate the independently measured chip temperature with qubit energy relaxation and dephasing times, demonstrating the utility of this approach for diagnosing temperature-dependent decoherence mechanisms. These results establish integrated Dayem bridges as a simple, non-invasive, and scalable tool for cryogenic hardware development, and on chip thermometry in superconducting quantum circuits.
A classical thermometer typically works by exchanging energy with the system being measured until it comes to equilibrium, at which point the readout is related to the final energy state of the thermometer. A recent paper noted that with a quantum thermometer consisting of a single spin/qubit, temperature discrimination is better achieved at finite times rather than once equilibration is essentially complete. Furthermore, preparing a qubit thermometer in a state with quantum coherence instead of an incoherent one improves its sensitivity to temperature differences. Implementing a recent proposal for efficiently emulating an arbitrary quantum channel, we use the quantum polarisation state of individual photons as models of "single-qubit thermometers" which evolve for a certain time in contact with a thermal bath. We investigate the optimal thermometer states for temperature discrimination, and the optimal interaction times, confirming that there is a broad regime where quantum coherence provides a significant improvement. We also discuss the more practical question of thermometers composed of a finite number of spins/qubits (greater than one), and characterize the performance of an adaptive protocol for making optimal use of all the qubits.