SPIE Quantum Technologies

Light shift mitigation for the 5S-5D two-photon transition in rubidium

Roman Blum, Stefan Kundermann, Thibaud Ruelle, Steve Lecomte, Sylvain Karlen

Published Apr 5, 2024• 1 citation
Publisher

Abstract

The rubidium two-photon optical atomic clock is a promising technology for applications that require a compact yet stable timekeeping device. However, its long-term frequency stability is often limited by the light shift (or AC Stark effect). In a rubidium two-photon frequency standard, we demonstrate in experiment that the light shift of the 778.1 nm wavelength probe beam can be mitigated with another, 1556.2 nm wavelength beam.

DOI
10.1117/12.3027257

Related papers

Suppressing the light shift in a two-photon rubidium optical frequency reference

Yorick Andeweg, John E. Kitching, Matthew T. Hummon

The two-photon transition in rubidium is an attractive candidate for use in the next generation of field-deployable atomic clocks and frequency references. However, this transition is known to suffer from a large AC Stark shift, through which fluctuations in the intensity of the interrogation laser cause fluctuations of the clock frequency, often limiting long-term stability. We implement an interrogation protocol known as the auto-compensated shift (ACS) in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical intensity fluctuations by a factor of 1000. ACS alleviates the tradeoff between short-term and long-term stability imposed by the light shift and enables us to simultaneously achieve a fractional instability of 3 x 10^-14 at an integration time of 1 s and 2 x 10^-14 at an integration time of 10,000 s. We also examine a stability limit imposed on clocks using ACS by frequency noise on the laser.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

A Comprehensive Review of Rubidium Two-Photon Vapor Cell Optical Clock: Long-Term Performance Limitations and Potential Improvements

Asagwegbe C. Obaze-Adeleke, Bryan Semon, Thejesh Bandi

Two-photon vapor cell-based optical clocks are strong candidates for next-generation portable atomic standards, offering simplicity, compactness, and high performance. Their narrow clock transitions with counter-propagating beams enable first-order Doppler-free operation. However, systematic perturbations such as the AC Stark shift, temperature-induced shift, and drifts resulting from the laser system pose challenges cause instabilities to medium- to long-term performance. This paper provides a comprehensive overview of Rb two-photon vapor cell optical standards, focusing on the long-term performance-limiting effects and potential mitigation strategies, aiming for clock stabilities better than 1 × 10−15 over the averaging time of a day and beyond.

Photonics•May 20, 2025•14 citations

Frequency shifts due to Stark effects on a rubidium two-photon transition

Kyle W. Martin, Benjamin Stuhl, Jon Eugenio +4 more

The $5{S}_{1/2}\ensuremath{\rightarrow}5{D}_{5/2}$ two-photon transition in Rb is of interest for the development of a compact optical atomic clock. Here we present a rigorous calculation of the 778.1-nm ac Stark shift $[2.30(4)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{(\mathrm{mW}/{\mathrm{mm}}^{2})}^{\ensuremath{-}1}]$ that is in good agreement with our measured value of $2.5(2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{(\mathrm{mW}/{\mathrm{mm}}^{2})}^{\ensuremath{-}1}$. We include a calculation of the temperature-dependent blackbody radiation (BBR) shift, and we predict that the clock could be operated either with zero net BBR shift $[T=495.9(27)$ K] or with zero first-order sensitivity $[T=368.1(14)$ K]. Also described is the calculation of the dc Stark shift of $5.5(1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}/(\mathrm{V}/{\mathrm{cm}}^{2}$) as well as clock sensitivities to optical alignment variations in both a cat's eye and a flat mirror retroreflector. Finally, we characterize these Stark effects, discussing mitigation techniques necessary to reduce final clock instabilities.

arXiv:1907.10805•Physical Review A•Aug 28, 2019•47 citations

Compact two-photon optical clock with a long-term stability of 8.1 × 10−15 without linear drift removal

Chen Feng, Xinrui Luo, Ji’an Duan +5 more

In this work, we stabilize a 1556.2 nm fiber laser to the 5S1/2 → 5D5/2 two-photon transition in 87Rb in a carefully designed compact physics package. A commercial fiber frequency comb divides the optical frequency into 200 MHz microwave output, which demonstrates a fractional frequency stability of 2.2 × 10-13 at τ = 1 s and 8.1 × 10-15 at τ = 4000 s, without linear drift removal. We analyze the systematic effect on the short-term and long-term stabilities in detail. The short-term and long-term stabilities are limited by shot noise and ac Stark shift, respectively. The rubidium two-photon optical clock is a promising candidate for the next-generation space-borne atomic clock.

Review of Scientific Instruments•Dec 1, 2025•3 citations

Frequency stability performance of a laser pumped rubidium vapor cell atomic frequency standard

M. Zhu

The AC Stark shift (the light shift) is very important in the performance of laser-pumped vapor cell atomic frequency standards. The frequency stability of a compact rubidium vapor cell atomic frequency standard with an AC Stark shift suppression laser pumping method was evaluated. The applications of such a device include serving as primary reference clocks in communication systems such as Stratum 1 reference clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•1 citation

Studies on Potential Light Shift Mitigation Method for Rubidium Two-photon Transition Through Excited State Zeeman Shift Control

Bryan Semon, Asagwegbe C. Obaze-Adeleke, Thejesh Bandi

AC Stark effect, also known as light shift effect, is a dominating factor limiting the long-term stability of the rubidium optical clock. We propose a method of locking the laser loop which allows the Zeeman shift to act as a counterbalance to the light shift. In pursuit of this goal, we show detailed calculations for the excited state Zeeman splitting in the intermediate magnetic field regime (0~G to 12~G) and demonstrate measurements with quantitative spectroscopic data confirming to within $\pm$ 90~kHz/G the predicted Zeeman shift calculations for the $F_e = 4, m_f = -2$ transition. In this proof-of-concept setup the method of light shift compensation via Zeeman shift control to within 3.5~kHz is demonstrated. Further improvements in the magnetic field control could enhance the accuracy for controlling the light shift effect to well below 1~kHz, limited by noise in the applied Zeeman shift which is proportional to both the stability of the current in the coil and the Zeeman sensitivity of the chosen transition.

Journal of the Optical Society of America B•Nov 3, 2026•0 citations
The rubidium two-photon optical atomic clock is a promising technology for applications that require a compact yet stable timekeeping device. However, its long-term frequency stability is often limited by the light shift (or AC Stark effect). In a rubidium two-photon frequency standard, we demonstrate in experiment that the light shift of the 778.1 nm wavelength probe beam can be mitigated with another, 1556.2 nm wavelength beam.
The two-photon transition in rubidium is an attractive candidate for use in the next generation of field-deployable atomic clocks and frequency references. However, this transition is known to suffer from a large AC Stark shift, through which fluctuations in the intensity of the interrogation laser cause fluctuations of the clock frequency, often limiting long-term stability. We implement an interrogation protocol known as the auto-compensated shift (ACS) in a two-photon rubidium optical frequency reference, reducing its sensitivity to optical intensity fluctuations by a factor of 1000. ACS alleviates the tradeoff between short-term and long-term stability imposed by the light shift and enables us to simultaneously achieve a fractional instability of 3 x 10^-14 at an integration time of 1 s and 2 x 10^-14 at an integration time of 10,000 s. We also examine a stability limit imposed on clocks using ACS by frequency noise on the laser.
Two-photon vapor cell-based optical clocks are strong candidates for next-generation portable atomic standards, offering simplicity, compactness, and high performance. Their narrow clock transitions with counter-propagating beams enable first-order Doppler-free operation. However, systematic perturbations such as the AC Stark shift, temperature-induced shift, and drifts resulting from the laser system pose challenges cause instabilities to medium- to long-term performance. This paper provides a comprehensive overview of Rb two-photon vapor cell optical standards, focusing on the long-term performance-limiting effects and potential mitigation strategies, aiming for clock stabilities better than 1 × 10−15 over the averaging time of a day and beyond.
The $5{S}_{1/2}\ensuremath{\rightarrow}5{D}_{5/2}$ two-photon transition in Rb is of interest for the development of a compact optical atomic clock. Here we present a rigorous calculation of the 778.1-nm ac Stark shift $[2.30(4)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{(\mathrm{mW}/{\mathrm{mm}}^{2})}^{\ensuremath{-}1}]$ that is in good agreement with our measured value of $2.5(2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{(\mathrm{mW}/{\mathrm{mm}}^{2})}^{\ensuremath{-}1}$. We include a calculation of the temperature-dependent blackbody radiation (BBR) shift, and we predict that the clock could be operated either with zero net BBR shift [T=495.9(27)[T=495.9(27)[T=495.9(27) K] or with zero first-order sensitivity [T=368.1(14)[T=368.1(14)[T=368.1(14) K]. Also described is the calculation of the dc Stark shift of $5.5(1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}/(\mathrm{V}/{\mathrm{cm}}^{2}$) as well as clock sensitivities to optical alignment variations in both a cat's eye and a flat mirror retroreflector. Finally, we characterize these Stark effects, discussing mitigation techniques necessary to reduce final clock instabilities.
In this work, we stabilize a 1556.2 nm fiber laser to the 5S1/2 → 5D5/2 two-photon transition in 87Rb in a carefully designed compact physics package. A commercial fiber frequency comb divides the optical frequency into 200 MHz microwave output, which demonstrates a fractional frequency stability of 2.2 × 10-13 at τ = 1 s and 8.1 × 10-15 at τ = 4000 s, without linear drift removal. We analyze the systematic effect on the short-term and long-term stabilities in detail. The short-term and long-term stabilities are limited by shot noise and ac Stark shift, respectively. The rubidium two-photon optical clock is a promising candidate for the next-generation space-borne atomic clock.
AC Stark effect, also known as light shift effect, is a dominating factor limiting the long-term stability of the rubidium optical clock. We propose a method of locking the laser loop which allows the Zeeman shift to act as a counterbalance to the light shift. In pursuit of this goal, we show detailed calculations for the excited state Zeeman splitting in the intermediate magnetic field regime (0~G to 12~G) and demonstrate measurements with quantitative spectroscopic data confirming to within ±\pm± 90~kHz/G the predicted Zeeman shift calculations for the Fe=4,mf=−2F_e = 4, m_f = -2Fe​=4,mf​=−2 transition. In this proof-of-concept setup the method of light shift compensation via Zeeman shift control to within 3.5~kHz is demonstrated. Further improvements in the magnetic field control could enhance the accuracy for controlling the light shift effect to well below 1~kHz, limited by noise in the applied Zeeman shift which is proportional to both the stability of the current in the coil and the Zeeman sensitivity of the chosen transition.