Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical and Quantum Sensing and Precision Metrology II

Time-domain control of a spatial-domain atomic beam interferometer

Adam T. Black, Hans J. Haucke, Sunil Kumar Upadhyay, Ryan K. O'Donnell, Jonathan M. Kwolek

Published Mar 13, 2024• 2 citations
Publisher

Abstract

Atom interferometers that operate in the spatial domain through continuous measurement of an atomic beam provide benefits in the elimination of sensor dead time and reduced sensitivity to certain noise sources. Further improving its operation, time-domain control of a spatial-domain interferometer can provide necessary methods of error suppression and dynamic range improvement. We model numerically and experimentally demonstrate methods of time-domain control in a 3D-cooled atomic beam interferometer. We demonstrate suppression of magnetic-field-induced phase noise through rapid reversal of the direction of inertial sensitivity at a rate faster than the inverse interrogation time of the interferometer.

DOI
10.1117/12.3011736

Related papers

Continuous Sub-Doppler-Cooled Atomic Beam Interferometer for Inertial Sensing

Jonathan M. Kwolek, Adam T. Black

In atomic sensors, continuous interrogation of laser-cooled atoms carries the benefits of improved sensitivity and high measurement bandwidth. However, cooling in proximity to coherent atomic state evolution can degrade performance in compact systems, due to decoherence. This study demonstrates an inertially sensitive matter-wave interferometer in a three-dimensionally-cooled atomic beam that mitigates decoherence while operating continuously. The technique could enable compact atom-interferometer sensors that measure continuously and with high sensitivity on dynamic platforms.

arXiv:2112.09666•Physical Review Applied•Feb 23, 2022•43 citations

Noise resilience in a high-bandwidth atom interferometer

Jonathan M. Kwolek, Sunil Kumar Upadhyay, Adam T. Black

The utility of inertial sensors depends on resilience against real-world dynamics and noise. Atom interferometry offers a sensing technology with the advantage of good long-term stability, high sensitivity, and accuracy. High measurement bandwidth improves an atom interferometer's ability to reject errors due to dynamics and noise. Here we demonstrate resilience against time-varying environmental noise by rapidly switching the direction of inertial sensitivity in the atom interferometer through a common technique known as k-reversal. We demonstrate sub-interrogation-time k-reversal at 592 Hz in a cold-beam atomic interferometer with an inverse interrogation time of 148 Hz. The interferometer fringe output is read out continuously and post-processed using nonlinear Kalman filters to determine both the inertial and error contributions to the output phase. The resulting power spectral densities show a significant reduction of phase error due to a noisy magnetic field as the k-reversal frequency increases.

arXiv:2504.07236•Physical Review Applied•Aug 14, 2025•3 citations

Progress toward a dual-beam 3D-cooled atom interferometer gyroscope

Adam T. Black, Jonathan M. Kwolek, Sunil Kumar Upadhyay

Atom interferometers make use of the interference of matter waves for precise measurement of motion. Employing 3D-laser-cooled atoms provides improved fringe contrast, while measuring in a continuous beam architecture provides high-bandwidth measurement, error suppression of time-varying signals, and the elimination of measurement dead time. In this paper, we discuss the initial observation of interference signals in a dual-beam, 3D-cooled atomic beam interferometer architecture. Additionally, we perform initial characterization of the response of the atom interferometer signal to laser intensity and frequency noise.

Optical and Quantum Sensing and Precision Metrology II•Mar 19, 2025•0 citations

Cold-atom inertial sensor without deadtime

Bess Fang, Denis Savoie, N. Mielec +5 more

We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times [1]. This is illustrated in Fig. 1. Dead times and noise aliasing are consequences of the sequential operation which is intrinsic to cold-atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√Hz in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude [2-4]. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

High-bandwidth, sub-Doppler atomic beam interferometry

Adam T. Black, Jonathan M. Kwolek

Through the use of a high-flux rubidium beam source with sub-Doppler temperatures in three dimensions, we have demonstrated an inertially sensitive atom interferometer featuring high contrast, low noise, and continuous measurement with high bandwidth. We describe the cold-atom source and the optical design that optimizes interferometer contrast. Finally, we demonstrate useful features enabled by this architecture, such as continuous phase shear readout and rapid reversal of inertial sensitivity. This demonstration may enable future cold-atom sensors that measure with both high sensitivity and high bandwidth.

Optical and Quantum Sensing and Precision Metrology II•Mar 3, 2022•0 citations

Continuous cold atom inertial sensor with 1 nrad.s^-1 rotation stability (Conference Presentation)

Rémi Geiger, Indranil Dutta, Denis Savoie +4 more

We report the first operation of a cold atom inertial sensor without dead time. Dead times in conventional cold atom interferometers originate from the preparation of a cold atom source prior to its injection in the interferometer and where information on inertial signals is lost. We use a sequence where we simultaneously prepare a cold atom source and operate a light pulse atom interferometer to circumvent the dead time limitation. Therefore the sensor continuously captures all the dynamics with respect to an inertial frame. We show that the continuous operation does not degrade the sensitivity and stability of the atom interferometer, by demonstrating a rotation sensitivity level of less than 1 nrad/s after 10 000 s of integration time. Such a sensitivity level improves previous results by more than an order of magnitude and opens applications of cold atom gyroscopes in inertial navigation and geophysics.

•Aug 3, 2016•1 citation
Atom interferometers that operate in the spatial domain through continuous measurement of an atomic beam provide benefits in the elimination of sensor dead time and reduced sensitivity to certain noise sources. Further improving its operation, time-domain control of a spatial-domain interferometer can provide necessary methods of error suppression and dynamic range improvement. We model numerically and experimentally demonstrate methods of time-domain control in a 3D-cooled atomic beam interferometer. We demonstrate suppression of magnetic-field-induced phase noise through rapid reversal of the direction of inertial sensitivity at a rate faster than the inverse interrogation time of the interferometer.
In atomic sensors, continuous interrogation of laser-cooled atoms carries the benefits of improved sensitivity and high measurement bandwidth. However, cooling in proximity to coherent atomic state evolution can degrade performance in compact systems, due to decoherence. This study demonstrates an inertially sensitive matter-wave interferometer in a three-dimensionally-cooled atomic beam that mitigates decoherence while operating continuously. The technique could enable compact atom-interferometer sensors that measure continuously and with high sensitivity on dynamic platforms.
The utility of inertial sensors depends on resilience against real-world dynamics and noise. Atom interferometry offers a sensing technology with the advantage of good long-term stability, high sensitivity, and accuracy. High measurement bandwidth improves an atom interferometer's ability to reject errors due to dynamics and noise. Here we demonstrate resilience against time-varying environmental noise by rapidly switching the direction of inertial sensitivity in the atom interferometer through a common technique known as k-reversal. We demonstrate sub-interrogation-time k-reversal at 592 Hz in a cold-beam atomic interferometer with an inverse interrogation time of 148 Hz. The interferometer fringe output is read out continuously and post-processed using nonlinear Kalman filters to determine both the inertial and error contributions to the output phase. The resulting power spectral densities show a significant reduction of phase error due to a noisy magnetic field as the k-reversal frequency increases.
Atom interferometers make use of the interference of matter waves for precise measurement of motion. Employing 3D-laser-cooled atoms provides improved fringe contrast, while measuring in a continuous beam architecture provides high-bandwidth measurement, error suppression of time-varying signals, and the elimination of measurement dead time. In this paper, we discuss the initial observation of interference signals in a dual-beam, 3D-cooled atomic beam interferometer architecture. Additionally, we perform initial characterization of the response of the atom interferometer signal to laser intensity and frequency noise.
We report the operation of a cold-atom inertial sensor in a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer in order to eliminate dead times [1]. This is illustrated in Fig. 1. Dead times and noise aliasing are consequences of the sequential operation which is intrinsic to cold-atom interferometers. Both phenomena have deleterious effects on the performance of these sensors. We show that our continuous operation improves the short-term sensitivity of atom interferometers, by demonstrating a record rotation sensitivity of 100 nrad.s-1/√Hz in a cold-atom gyroscope of 11 cm2Sagnac area. We also demonstrate a rotation stability of 1 nrad.s-1after 104s of integration, improving previous results by an order of magnitude [2-4]. We expect that the continuous operation will allow cold-atom inertial sensors with long interrogation time to reach their full sensitivity, determined by the quantum noise limit.
Through the use of a high-flux rubidium beam source with sub-Doppler temperatures in three dimensions, we have demonstrated an inertially sensitive atom interferometer featuring high contrast, low noise, and continuous measurement with high bandwidth. We describe the cold-atom source and the optical design that optimizes interferometer contrast. Finally, we demonstrate useful features enabled by this architecture, such as continuous phase shear readout and rapid reversal of inertial sensitivity. This demonstration may enable future cold-atom sensors that measure with both high sensitivity and high bandwidth.
We report the first operation of a cold atom inertial sensor without dead time. Dead times in conventional cold atom interferometers originate from the preparation of a cold atom source prior to its injection in the interferometer and where information on inertial signals is lost. We use a sequence where we simultaneously prepare a cold atom source and operate a light pulse atom interferometer to circumvent the dead time limitation. Therefore the sensor continuously captures all the dynamics with respect to an inertial frame. We show that the continuous operation does not degrade the sensitivity and stability of the atom interferometer, by demonstrating a rotation sensitivity level of less than 1 nrad/s after 10 000 s of integration time. Such a sensitivity level improves previous results by more than an order of magnitude and opens applications of cold atom gyroscopes in inertial navigation and geophysics.