Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Photon subtraction with a Mach–Zehnder interferometer and its application to entanglement enhancement

ShengLi Zhang, Song Yang, JingTing Ma

Published Feb 21, 2024• 4 citations
Publisher

Abstract

Photon subtraction (PS) is an important operation for optic quantum information processing. Conventional PS is implemented using a single linear beam splitter (BS) and photon detector. However, in this study, we show that the PS effect can be enhanced using two beam splitters and an optional phase modulator. This can be considered PS with an extended version of the well-known Mach–Zehnder (MZ) interferometer. By tuning the transmittance of the two beam splitters and phase modulator, the probability of success can be considerably improved over that of the original PS scheme with a single BS and photon detector. Moreover, if applied to a single-photon input, our proposed scheme can even implement deterministic PS, which is almost impossible for the original scheme with a single BS and photon detector. Owing to the higher probability of success, applying the PSMZ method to the entanglement enhancement of a very weak two-mode squeezed vacuum state is straightforward. Our result is helpful for improving the yield of output entanglement.

DOI
10.1364/josab.518234

Related papers

Photon subtraction as a way to increase sensitivity of the Mach–Zehnder interferometer

Alina S Fassakhova, Alexander A Koksharov, Dmitry Kuts +1 more

Abstract Choice of the quantum probe state is of key importance to enhance the sensitivity of the Mach–Zehnder (MZ) interferometer beyond the classical one and even approach the quantum Cramér–Rao bound. According to the work of Caves (Caves 1981 Phys. Rev. D 23 1693), the quantum MZ interferometer is a phase-dependent one operating with single-mode squeezed vacuum (SMSV) light coupled with a coherent state. We use the SMSV state with squeezing <10 dB and report a gain in sensitivity of the phase-dependent MZ interferometer of more than 10 dB compared to the original result (Pezze and Smerzi 2008 Phys. Rev. Lett. 100 073601) via photon subtraction. The gain in sensitivity is also observed when measuring the difference in output intensities of the SMSV state with squeezing of < 3 dB from which two, four, and six photons are subtracted and a large coherent state. Overall, subtracting photons from the initially weakly squeezed light can prove to be a more efficient strategy in quantum MZ interferometry compared to highly squeezed SMSV state generation.

Laser Physics Letters•Mar 19, 2025•1 citation

Gain sensitivity of the Mach–Zehnder interferometer by photon subtraction

Mikhail S. Podoshvedov, Sergey A. Podoshvedov

Abstract The phase sensitivity of a Mach–Zehnder (MZ) interferometer with a two-mode squeezed vacuum (TMSV) probe state is studied. At the initial stage, the TMSV state is deterministically converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted via photon-number resolving measurement in auxiliary measurement modes. The new probe state can already demonstrate gain sensitivity of more than 20 dB with input squeezing of 5 dB and follow Heisenberg scaling. The phase sensitivity of the MZ interferometer, estimated by measuring the intensity difference of two measurement-induced continuous variable states, can surpass the ultimate one with SMSV probe states, at least, with squeezing less than 5 dB. In general, the strategy with preliminary subtraction of photons significantly increases the estimate potential of weakly squeezed states as the probe in MZ phase-dependent interferometry; in particular, it is more effective compared to generating highly squeezed TMSV states or SMSV states.

Laser Physics Letters•Nov 15, 2024•5 citations

Quantum Metrology Via Quantum Non-Gaussian States Under Noise

Sang Woo Park, Changsuk Noh, Hyunchul Nha

Quantum metrology aims to achieve measurement precision that surpasses classical limits in the estimation of physical parameters. In realistic conditions, however, its advantage can be diminished by interactions between a quantum system and its environment. This necessitates careful design of quantum resources that can sustain enhanced performance even under noise. Here, we investigate how a quantum non-Gaussian operation can provide an advantage in noisy quantum metrology. Specifically, we examine the effect of single-photon subtraction applied to a two-mode squeezed vacuum state in the task of phase estimation using a Mach–Zehnder interferometer under photon loss. The single-photon subtraction can be implemented either before or after the first beam splitter in the interferometer. By evaluating the quantum Fisher information for both the original and the photon-subtracted states, we assess the potential enhancement in sensing precision. We show that the enhancement occurs when photon subtraction is performed before the first beam splitter, provided that loss acts only on the signal mode. Our findings shed light on the role of non-Gaussian operations in noisy quantum metrology, clarifying when photon subtraction can yield a genuine advantage over Gaussian resources.

Fluctuation and Noise Letters•Jan 10, 2026•0 citations

Phase sensitivity via photon-subtraction operations inside Mach-Zehnder interferometer

Zhou, Qisi, Kang, Qinqian, Jiang, Tao +4 more

Based on the conventional Mach-Zehnder interferometer, we propose a metrological scheme to improve phase sensitivity. In this scheme, we use a coherent state and a squeezed vacuum state as input states, employ multi-photon-subtraction operations and make intensity-detection or homodyne-detection. We study phase sensitivity, quantum Fisher information and quantum Cramér-Rao bound under both ideal and lossy conditions. The results indicate that choosing an appropriate detection method and photon subtraction scheme can significantly enhance the phase sensitivity and robustness against photon losses. Even under lossy conditions, the multi-photon subtraction schemes can surpass the standard quantum limit. Notably, the homodyne detection method can even break through the Heisenberg limit. Moreover, increasing the number of photon-subtracted can enhance both phase sensitivity and quantum Fisher information. This research highlights the significant value of this scheme in quantum precision measurement.

arXiv:2505.04499•May 7, 2025•0 citations

Gain sensitivity of the Mach-Zehnder interferometer by photon subtraction strategy

Mikhail S. Podoshvedov, Sergey A. Podoshvedov

We study sensitivity of phase estimation of Mach-Zehnder (MZ) interferometer with original two-mode squeezed vacuum (TMSV) state. At the initial stage, the TMSV state is converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted by measurement by photon-number resolving (PNR) detector in auxiliary modes. New measurement-induced continuous variable (CV) states of a certain parity can already demonstrate gain sensitivity more than 20 dB in relation to the initial SMSV states at the output from the MZ interferometer and follow to Heisenberg scaling in the case of subtracting a large number of photons in the measuring channels for practical values of the SMSV squeezing 5 dB>. Using only one measurement-induced CV state of a certain parity together with the SMSV state shows an increase in sensitivity of no more than 11 dB. We show that the sensitivity of the phase estimation obtained by measuring the intensity difference of two measurement-induced CV states in two arms of the MZ interferometer can surpass quantum Cramer-Rao (QCR) boundary of the original two SMSV states just in the practical range of input squeezing 5 dB>. In general, the strategy with preliminary subtraction of photons from two SMSV enables greatly enhance the sensitivity of the MZ interferometer in the practical case of small values of squeezing.

arXiv:2405.16261•May 25, 2024•0 citations

Potential of photon-subtracted CV states towards gain sensitivity of the Mach-Zehnder interferometer

Mikhail S. Podoshvedov, Sergey A. Podoshvedov

Quantum Cramer-Rao (QCR) bound is attached to a particular nonclassical state, therefore appropriate choice of the probe state is of the key importance to enhance sensitivity beyond classical one. Since the work of C.M. Caves (Phys. Rev. D 23 1693 (1981)) Mach-Zehnder (MZ) interferometry operates with single-mode squeezed vacuum (SMSV) light coupled with a coherent state. We report the gain sensitivity of the phase-dependent MZ interferometer by more than 10 dB compared to the original result (Phys. Rev. Lett. 100, 073601 (2008)) by using SMSV state with squeezing <10 dB from which a certain number of photons was initially subtracted. The gain sensitivity is also observed when measuring the difference of output intensities of the SMSV state with squeezing <3 dB from which 2,4,6 photons are subtracted and large coherent state. Overall, subtracting photons from the initially weakly squeezed light can prove to be a more efficient strategy in the quantum MZ interferometry compared to highly squeezed SMSV state generation.

arXiv:2502.02094•Feb 4, 2025•0 citations
Photon subtraction (PS) is an important operation for optic quantum information processing. Conventional PS is implemented using a single linear beam splitter (BS) and photon detector. However, in this study, we show that the PS effect can be enhanced using two beam splitters and an optional phase modulator. This can be considered PS with an extended version of the well-known Mach–Zehnder (MZ) interferometer. By tuning the transmittance of the two beam splitters and phase modulator, the probability of success can be considerably improved over that of the original PS scheme with a single BS and photon detector. Moreover, if applied to a single-photon input, our proposed scheme can even implement deterministic PS, which is almost impossible for the original scheme with a single BS and photon detector. Owing to the higher probability of success, applying the PSMZ method to the entanglement enhancement of a very weak two-mode squeezed vacuum state is straightforward. Our result is helpful for improving the yield of output entanglement.
Abstract Choice of the quantum probe state is of key importance to enhance the sensitivity of the Mach–Zehnder (MZ) interferometer beyond the classical one and even approach the quantum Cramér–Rao bound. According to the work of Caves (Caves 1981 Phys. Rev. D 23 1693), the quantum MZ interferometer is a phase-dependent one operating with single-mode squeezed vacuum (SMSV) light coupled with a coherent state. We use the SMSV state with squeezing <10 dB and report a gain in sensitivity of the phase-dependent MZ interferometer of more than 10 dB compared to the original result (Pezze and Smerzi 2008 Phys. Rev. Lett. 100 073601) via photon subtraction. The gain in sensitivity is also observed when measuring the difference in output intensities of the SMSV state with squeezing of < 3 dB from which two, four, and six photons are subtracted and a large coherent state. Overall, subtracting photons from the initially weakly squeezed light can prove to be a more efficient strategy in quantum MZ interferometry compared to highly squeezed SMSV state generation.
Abstract The phase sensitivity of a Mach–Zehnder (MZ) interferometer with a two-mode squeezed vacuum (TMSV) probe state is studied. At the initial stage, the TMSV state is deterministically converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted via photon-number resolving measurement in auxiliary measurement modes. The new probe state can already demonstrate gain sensitivity of more than 20 dB with input squeezing of 5 dB and follow Heisenberg scaling. The phase sensitivity of the MZ interferometer, estimated by measuring the intensity difference of two measurement-induced continuous variable states, can surpass the ultimate one with SMSV probe states, at least, with squeezing less than 5 dB. In general, the strategy with preliminary subtraction of photons significantly increases the estimate potential of weakly squeezed states as the probe in MZ phase-dependent interferometry; in particular, it is more effective compared to generating highly squeezed TMSV states or SMSV states.
Quantum metrology aims to achieve measurement precision that surpasses classical limits in the estimation of physical parameters. In realistic conditions, however, its advantage can be diminished by interactions between a quantum system and its environment. This necessitates careful design of quantum resources that can sustain enhanced performance even under noise. Here, we investigate how a quantum non-Gaussian operation can provide an advantage in noisy quantum metrology. Specifically, we examine the effect of single-photon subtraction applied to a two-mode squeezed vacuum state in the task of phase estimation using a Mach–Zehnder interferometer under photon loss. The single-photon subtraction can be implemented either before or after the first beam splitter in the interferometer. By evaluating the quantum Fisher information for both the original and the photon-subtracted states, we assess the potential enhancement in sensing precision. We show that the enhancement occurs when photon subtraction is performed before the first beam splitter, provided that loss acts only on the signal mode. Our findings shed light on the role of non-Gaussian operations in noisy quantum metrology, clarifying when photon subtraction can yield a genuine advantage over Gaussian resources.
Based on the conventional Mach-Zehnder interferometer, we propose a metrological scheme to improve phase sensitivity. In this scheme, we use a coherent state and a squeezed vacuum state as input states, employ multi-photon-subtraction operations and make intensity-detection or homodyne-detection. We study phase sensitivity, quantum Fisher information and quantum Cramér-Rao bound under both ideal and lossy conditions. The results indicate that choosing an appropriate detection method and photon subtraction scheme can significantly enhance the phase sensitivity and robustness against photon losses. Even under lossy conditions, the multi-photon subtraction schemes can surpass the standard quantum limit. Notably, the homodyne detection method can even break through the Heisenberg limit. Moreover, increasing the number of photon-subtracted can enhance both phase sensitivity and quantum Fisher information. This research highlights the significant value of this scheme in quantum precision measurement.
We study sensitivity of phase estimation of Mach-Zehnder (MZ) interferometer with original two-mode squeezed vacuum (TMSV) state. At the initial stage, the TMSV state is converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted by measurement by photon-number resolving (PNR) detector in auxiliary modes. New measurement-induced continuous variable (CV) states of a certain parity can already demonstrate gain sensitivity more than 20 dB in relation to the initial SMSV states at the output from the MZ interferometer and follow to Heisenberg scaling in the case of subtracting a large number of photons in the measuring channels for practical values of the SMSV squeezing 5 dB>. Using only one measurement-induced CV state of a certain parity together with the SMSV state shows an increase in sensitivity of no more than 11 dB. We show that the sensitivity of the phase estimation obtained by measuring the intensity difference of two measurement-induced CV states in two arms of the MZ interferometer can surpass quantum Cramer-Rao (QCR) boundary of the original two SMSV states just in the practical range of input squeezing 5 dB>. In general, the strategy with preliminary subtraction of photons from two SMSV enables greatly enhance the sensitivity of the MZ interferometer in the practical case of small values of squeezing.
Quantum Cramer-Rao (QCR) bound is attached to a particular nonclassical state, therefore appropriate choice of the probe state is of the key importance to enhance sensitivity beyond classical one. Since the work of C.M. Caves (Phys. Rev. D 23 1693 (1981)) Mach-Zehnder (MZ) interferometry operates with single-mode squeezed vacuum (SMSV) light coupled with a coherent state. We report the gain sensitivity of the phase-dependent MZ interferometer by more than 10 dB compared to the original result (Phys. Rev. Lett. 100, 073601 (2008)) by using SMSV state with squeezing <10 dB from which a certain number of photons was initially subtracted. The gain sensitivity is also observed when measuring the difference of output intensities of the SMSV state with squeezing <3 dB from which 2,4,6 photons are subtracted and large coherent state. Overall, subtracting photons from the initially weakly squeezed light can prove to be a more efficient strategy in the quantum MZ interferometry compared to highly squeezed SMSV state generation.