Improvement of phase sensitivity in SU(1,1) interferometer using number-conserving operations

Jie Tang, Jiahao Li, Yuexiang Cao, Ying Liu, HaoRan Hu, Ya Wang, Dan Wu, Zhi-Feng Deng, Huicun Yu, XingYu Wang, Huazhi Lun, Jiahua Wei, Lei Shi

Published Feb 9, 2024• 5 citations
Publisher

Abstract

We propose a theoretical scheme to improve the phase sensitivity by introducing the number-conserving generalized superposition of product into squeezed thermal state of the traditional SU(1,1) interferometer with intensity detection. We investigate the effect of different parameter and photon losses on phase sensitivity under the condition of the ideal and the realistic phase estimation process, respectively. Moreover, compared with the previous methods, our scheme can not only enhance the phase sensitivity, but also significantly suppress the photon losses with only first-order GSP operation. It means that our scheme needs less resources and less operations to obtain higher phase sensitivity. These above results indicate that our scheme is viable in the phase sensitivity improvement, which may have practical applications in quantum information processing.

DOI
10.1016/j.rinp.2024.107465

Related papers

Phase estimation of an SU(1,1) interferometer with a coherent superposition squeezed vacuum in a realistic case

Youke Xu, Shoukang Chang, Cunjin Liu +2 more

The phase sensitivity of SU(1,1) interferometer is investigated using a coherent state and an m-coherent superposition squeezed vacuum states as inputs and the intensity detection. Photon-subtraction, photon-addition and photon superposition are three special cases. Both ideal and realistic cases are considered. It is shown that the coefficient s of coherent superposition can modulate the performance of phase sensitivity, especially in a small squeezing region. Even in the presence of photon losses, the three-kind of non-Gaussian operations can achieve the improvement of measure precision, and the photon addition presents the best robustness compared to the photon subtraction and coherent superposition. For small squeezing, the first-order non-Gaussian operation may be the most preferred in improving phase sensitivity if considering the limitations of experimental conditions. Our results may be helpful for the practical application of quantum information.

Optics Express•Sep 22, 2022•11 citations

Phase estimation via number-conserving operation inside the SU(1,1) interferometer

Qingqian Kang, Zekun Zhao, Zhao, Teng +2 more

Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing number-conserving operations (PA-then-PS and PS-then-PA) within the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of number-conserving operations on the phase sensitivity, the quantum Fisher information, and the quantum Cramer-Rao bound under both ideal and photon losses scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the quantum Fisher information, and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the PS-then-PA scheme exhibits superior improvement in both ideal and photon losses cases in terms of phase sensitivity. Moreover, in the ideal case, PA-then-PS scheme slightly outperforms PS-then-PA scheme in terms of the quantum Fisher information and the Quantum Cramer-Rao. However, in the presence of photon losses, PS-then-PA scheme demonstrates a greater advantage.

arXiv:2406.06528•Mar 29, 2024•0 citations

Improvement of phase sensitivity in SU(1,1) interferometer via a Kerr nonlinear

Shoukang Chang, Wei Ye, Huan Zhang +3 more

We propose a theoretical scheme to enhance the phase sensitivity by introducing a Kerr nonlinear phase shift into the traditional SU(1,1) interferometer with a coherent state input and homodyne detection. We investigate the realistic effects of photon losses on phase sensitivity and quantum Fisher information. The results show that compared with the linear phase shift in SU(1,1) interferometer, the Kerr nonlinear case can not only enhance the phase sensitivity and quantum Fisher information, but also significantly suppress the photon losses. We also observe that at the same accessible parameters, internal losses have a greater influence on the phase sensitivity than the external ones. It is interesting that, our scheme shows an obvious advantage of low-cost input resources to obtain higher phase sensitivity and larger quantum Fisher information due to the introduction of nonlinear phase element.

arXiv:2103.07844•Mar 14, 2021•0 citations

Improving phase estimation using number-conserving operations

Huan Zhang, Wei Ye, Chaoping Wei +3 more

We propose a theoretical scheme to improve the resolution and precision of phase measurement with parity detection by using a nonclassical state generated by applying a number-conserving generalized superposition of products (GSP) operation, ${\left(sa{a}^{\ifmmode\dagger\else\textdagger\fi{}}+t{a}^{\ifmmode\dagger\else\textdagger\fi{}}a\right)}^{m}$ with ${s}^{2}+{t}^{2}=1$, on a two-mode squeezed vacuum (TMSV) state as the input of Mach-Zehnder interferometer. Then, the statistical properties of the proposed GSP-TMSV are investigated via average photon number (APN), antibunching effect, and two-mode squeezing. Particularly, both higher order $m$ GSP operation and lower proportion parameter $s$ are beneficial for presenting larger total APN, which leads to the improvement of quantum Fisher information (QFI). In addition, we also compare the phase measurement precisions with and without photon losses between our scheme and the previous photon subtraction or photon addition schemes. It is found that our scheme, especially for the case of $s=0$, even in the presence of photon losses, has the best performance via the enhanced phase resolution, sensitivity, and QFI when compared to those previous schemes. Interestingly, without losses, the standard quantum-noise limit (SQL) is always broken through for our scheme and the phase uncertainty associated with the state of our scheme is closer to the corresponding Heisenberg limit (HL) than the TMSV in the larger total APN region, especially for the case of two-side GSP operation $\left(m,n\right)\ensuremath{\in}\left(1,1\right)$. However, in the presence of photon losses, the HL cannot be beaten, but the SQL can be broken through, particularly for the large total APN regimes.

arXiv:2012.02441•Physical Review A•May 5, 2021•25 citations

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

Tao Jiang, Zekun Zhao, Qingqian Kang +4 more

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

Optics Express•Apr 14, 2025•7 citations

Improved phase sensitivity of an SU(1,1) interferometer based on the internal single-path local squeezing operation

Qingqian Kang, Zekun Zhao, Zhao, Teng +2 more

Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these interferometers is significantly affected by photon losses, especially internal losses, which can limit the overall measurement accuracy. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the effects of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can enhance the phase sensitivity and the QFI, effectively improving the robustness of the SU(1,1) interferometer against internal and external photon losses. Additionally, a larger squeezing parameter r leads to a better performance of the interferometer.

arXiv:2410.21292•Oct 13, 2024•0 citations
We propose a theoretical scheme to improve the phase sensitivity by introducing the number-conserving generalized superposition of product into squeezed thermal state of the traditional SU(1,1) interferometer with intensity detection. We investigate the effect of different parameter and photon losses on phase sensitivity under the condition of the ideal and the realistic phase estimation process, respectively. Moreover, compared with the previous methods, our scheme can not only enhance the phase sensitivity, but also significantly suppress the photon losses with only first-order GSP operation. It means that our scheme needs less resources and less operations to obtain higher phase sensitivity. These above results indicate that our scheme is viable in the phase sensitivity improvement, which may have practical applications in quantum information processing.
The phase sensitivity of SU(1,1) interferometer is investigated using a coherent state and an m-coherent superposition squeezed vacuum states as inputs and the intensity detection. Photon-subtraction, photon-addition and photon superposition are three special cases. Both ideal and realistic cases are considered. It is shown that the coefficient s of coherent superposition can modulate the performance of phase sensitivity, especially in a small squeezing region. Even in the presence of photon losses, the three-kind of non-Gaussian operations can achieve the improvement of measure precision, and the photon addition presents the best robustness compared to the photon subtraction and coherent superposition. For small squeezing, the first-order non-Gaussian operation may be the most preferred in improving phase sensitivity if considering the limitations of experimental conditions. Our results may be helpful for the practical application of quantum information.
Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing number-conserving operations (PA-then-PS and PS-then-PA) within the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of number-conserving operations on the phase sensitivity, the quantum Fisher information, and the quantum Cramer-Rao bound under both ideal and photon losses scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the quantum Fisher information, and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the PS-then-PA scheme exhibits superior improvement in both ideal and photon losses cases in terms of phase sensitivity. Moreover, in the ideal case, PA-then-PS scheme slightly outperforms PS-then-PA scheme in terms of the quantum Fisher information and the Quantum Cramer-Rao. However, in the presence of photon losses, PS-then-PA scheme demonstrates a greater advantage.
We propose a theoretical scheme to enhance the phase sensitivity by introducing a Kerr nonlinear phase shift into the traditional SU(1,1) interferometer with a coherent state input and homodyne detection. We investigate the realistic effects of photon losses on phase sensitivity and quantum Fisher information. The results show that compared with the linear phase shift in SU(1,1) interferometer, the Kerr nonlinear case can not only enhance the phase sensitivity and quantum Fisher information, but also significantly suppress the photon losses. We also observe that at the same accessible parameters, internal losses have a greater influence on the phase sensitivity than the external ones. It is interesting that, our scheme shows an obvious advantage of low-cost input resources to obtain higher phase sensitivity and larger quantum Fisher information due to the introduction of nonlinear phase element.
We propose a theoretical scheme to improve the resolution and precision of phase measurement with parity detection by using a nonclassical state generated by applying a number-conserving generalized superposition of products (GSP) operation, ${\left(sa{a}^{\ifmmode\dagger\else\textdagger\fi{}}+t{a}^{\ifmmode\dagger\else\textdagger\fi{}}a\right)}^{m}$ with s2+t2=1{s}^{2}+{t}^{2}=1s2+t2=1, on a two-mode squeezed vacuum (TMSV) state as the input of Mach-Zehnder interferometer. Then, the statistical properties of the proposed GSP-TMSV are investigated via average photon number (APN), antibunching effect, and two-mode squeezing. Particularly, both higher order mmm GSP operation and lower proportion parameter sss are beneficial for presenting larger total APN, which leads to the improvement of quantum Fisher information (QFI). In addition, we also compare the phase measurement precisions with and without photon losses between our scheme and the previous photon subtraction or photon addition schemes. It is found that our scheme, especially for the case of s=0s=0s=0, even in the presence of photon losses, has the best performance via the enhanced phase resolution, sensitivity, and QFI when compared to those previous schemes. Interestingly, without losses, the standard quantum-noise limit (SQL) is always broken through for our scheme and the phase uncertainty associated with the state of our scheme is closer to the corresponding Heisenberg limit (HL) than the TMSV in the larger total APN region, especially for the case of two-side GSP operation $\left(m,n\right)\ensuremath{\in}\left(1,1\right)$. However, in the presence of photon losses, the HL cannot be beaten, but the SQL can be broken through, particularly for the large total APN regimes.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these interferometers is significantly affected by photon losses, especially internal losses, which can limit the overall measurement accuracy. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the effects of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can enhance the phase sensitivity and the QFI, effectively improving the robustness of the SU(1,1) interferometer against internal and external photon losses. Additionally, a larger squeezing parameter r leads to a better performance of the interferometer.