Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symmetry

Phase Diffusion Mitigation in the Truncated Mach–Zehnder Interferometer

Quan Liao, Hongmei Ma, L. Q. Chen, Weiping Zhang, Chun-Hua Yuan

Published Feb 5, 2024• 2 citations
Publisher

Abstract

The presence of phase diffusion can lead to the loss of the advantages of quantum measurements. Squeezing is considered to be an effective method to reduce the detrimental effect of phase diffusion on the measurement. The Mach-Zehnder (MZ) interferometer has been exploited as a generic tool for precise phase measurement. Describing the reduction in quantum advantage caused by phase diffusion in an MZ interferometer that can be mitigated by squeezing is not easy to handle analytically, because the input state will change from a pure state to a mixed state after experiencing the diffusion noise in the MZ interferometer. We introduce a truncated MZ interferometer that can achieve the same potential phase sensitivity as the conventional MZ interferometer. This scheme can theoretically explain how phase diffusion reduces phase estimation and why squeezing counteracts in the presence of phase diffusion. Using the Gaussian property of the input state and the characteristic of Gaussian operation in the squeezing, the two orthogonal field quantities of the quantum state are squeezed and anti-squeezed to different degrees, and the analytic results are obtained. The truncated MZ interferometer is simpler to build and operate than the conventional MZ interferometer, and also mitigates the phase diffusion noise by the squeezing operation, thus making it useful for applications in precision metrology.

DOI
10.3390/sym16020187

Related papers

Robust phase sensitivity in Mach-Zehnder interferometer using photon added and subtracted squeezed coherent state

Shivani Singh, Priya Malpani, Anirban Pathak

For the precision-based measurements, Mach-Zehnder interferometry is a widely used technique. There are various ways to enhance the precision of Mach-Zehnder interferometer (MZI), e.g., having a non-classical input state is one of the ways to enhance the precision of the phase estimation performed by MZI. The phase estimation performed by MZI is investigated here by considering that the input states of MZI are different combinations of photon added and subtracted squeezed coherent states (PASCS and PSSCS). Using quantum Fisher information, it is shown that the use of PASCS in both the input modes of MZI, provides the most precise estimate of the unknown phase. This system is also analyzed in two different measurement scenarios -- single intensity detection (SID) and intensity difference detection (IDD). Systematic analysis has established that the intensity measurement might not be an optimal measurement scheme for phase estimation in MZI as phase and intensity correspond to non-commuting observables. The impact of the photon loss on the MZI-based phase estimation setup is also studied and it is found that PASCS is robust against photon loss, when the loss in MZI is low.

quant-pharXiv:2607.02984•Jul 6, 2026•0 citations

Mach–Zehnder interferometer with squeezed and EPR entangled optical fields

Xudong Yu, Wei Li, Shi-Yao Zhu +1 more

We study a scheme for Mach–Zehnder (MZ) interferometer as a quantum linear device by injecting two-mode squeezed input states into two ports of interferometer. Two-mode squeezed states can be changed into two types of inputs for MZ interferometer: two squeezed states and Einstein–Podolsky–Rosen (EPR) entangled states. The interference patterns of the MZ interferometer vary periodically as the relative phase of the two arms of the interferometer is scanned, and are measured by the balanced homodyne detection system. Our experiments show that there are different interference patterns and periodicity of the output quantum states for two cases which depend on the relative phase of input optical fields. Since MZ interferometer can be used to realize some quantum operations, this work will have the important applications in quantum information and metrology.

Chinese Physics B•Feb 1, 2016•5 citations

Gain sensitivity of the Mach–Zehnder interferometer by photon subtraction

Mikhail S. Podoshvedov, Sergey A. Podoshvedov

Abstract The phase sensitivity of a Mach–Zehnder (MZ) interferometer with a two-mode squeezed vacuum (TMSV) probe state is studied. At the initial stage, the TMSV state is deterministically converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted via photon-number resolving measurement in auxiliary measurement modes. The new probe state can already demonstrate gain sensitivity of more than 20 dB with input squeezing of 5 dB and follow Heisenberg scaling. The phase sensitivity of the MZ interferometer, estimated by measuring the intensity difference of two measurement-induced continuous variable states, can surpass the ultimate one with SMSV probe states, at least, with squeezing less than 5 dB. In general, the strategy with preliminary subtraction of photons significantly increases the estimate potential of weakly squeezed states as the probe in MZ phase-dependent interferometry; in particular, it is more effective compared to generating highly squeezed TMSV states or SMSV states.

Laser Physics Letters•Nov 15, 2024•5 citations

Enhanced phase estimation with a displaced two-mode squeezed coherent state

Pengxiang Ruan, Jun Liu, Dong-Xu Chen

Compared to classical state inputs, using quantum states in interferometers, especially squeezed states, can greatly improve the accuracy of the phase estimation. Here, we propose a scheme based on a Mach-Zehnder interferometer with a displaced two-mode squeezed coherent state input. The scheme employs both intensity difference detection and balanced homodyne detection to achieve high phase sensitivity. The displaced squeezed state exhibits higher accuracy and better robustness by theoretical calculations. For the state, the phase sensitivity of the quantum Cramér-Rao bound and intensity difference detection both exceed the shot noise limit. Additionally, we demonstrate that the proposed state is superior to the two-mode squeezed coherent state by analyzing different displacement operations. Under the presence of both the interferometric transmission loss and the detection loss, higher displacement strength yields higher robustness. To the best of our knowledge, our work provides new ideas for the field of precision measurement.

Optics Express•Nov 4, 2025•0 citations

Photon subtraction as a way to increase sensitivity of the Mach–Zehnder interferometer

Alina S Fassakhova, Alexander A Koksharov, Dmitry Kuts +1 more

Abstract Choice of the quantum probe state is of key importance to enhance the sensitivity of the Mach–Zehnder (MZ) interferometer beyond the classical one and even approach the quantum Cramér–Rao bound. According to the work of Caves (Caves 1981 Phys. Rev. D 23 1693), the quantum MZ interferometer is a phase-dependent one operating with single-mode squeezed vacuum (SMSV) light coupled with a coherent state. We use the SMSV state with squeezing <10 dB and report a gain in sensitivity of the phase-dependent MZ interferometer of more than 10 dB compared to the original result (Pezze and Smerzi 2008 Phys. Rev. Lett. 100 073601) via photon subtraction. The gain in sensitivity is also observed when measuring the difference in output intensities of the SMSV state with squeezing of < 3 dB from which two, four, and six photons are subtracted and a large coherent state. Overall, subtracting photons from the initially weakly squeezed light can prove to be a more efficient strategy in quantum MZ interferometry compared to highly squeezed SMSV state generation.

Laser Physics Letters•Mar 19, 2025•1 citation

PHASE MEASUREMENTS WITH A TWO-MODE SQUEEZED STATE OF LIGHT.

Gupta, Prasoon

Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.

•Jan 1, 2019•0 citations
The presence of phase diffusion can lead to the loss of the advantages of quantum measurements. Squeezing is considered to be an effective method to reduce the detrimental effect of phase diffusion on the measurement. The Mach-Zehnder (MZ) interferometer has been exploited as a generic tool for precise phase measurement. Describing the reduction in quantum advantage caused by phase diffusion in an MZ interferometer that can be mitigated by squeezing is not easy to handle analytically, because the input state will change from a pure state to a mixed state after experiencing the diffusion noise in the MZ interferometer. We introduce a truncated MZ interferometer that can achieve the same potential phase sensitivity as the conventional MZ interferometer. This scheme can theoretically explain how phase diffusion reduces phase estimation and why squeezing counteracts in the presence of phase diffusion. Using the Gaussian property of the input state and the characteristic of Gaussian operation in the squeezing, the two orthogonal field quantities of the quantum state are squeezed and anti-squeezed to different degrees, and the analytic results are obtained. The truncated MZ interferometer is simpler to build and operate than the conventional MZ interferometer, and also mitigates the phase diffusion noise by the squeezing operation, thus making it useful for applications in precision metrology.
For the precision-based measurements, Mach-Zehnder interferometry is a widely used technique. There are various ways to enhance the precision of Mach-Zehnder interferometer (MZI), e.g., having a non-classical input state is one of the ways to enhance the precision of the phase estimation performed by MZI. The phase estimation performed by MZI is investigated here by considering that the input states of MZI are different combinations of photon added and subtracted squeezed coherent states (PASCS and PSSCS). Using quantum Fisher information, it is shown that the use of PASCS in both the input modes of MZI, provides the most precise estimate of the unknown phase. This system is also analyzed in two different measurement scenarios -- single intensity detection (SID) and intensity difference detection (IDD). Systematic analysis has established that the intensity measurement might not be an optimal measurement scheme for phase estimation in MZI as phase and intensity correspond to non-commuting observables. The impact of the photon loss on the MZI-based phase estimation setup is also studied and it is found that PASCS is robust against photon loss, when the loss in MZI is low.
We study a scheme for Mach–Zehnder (MZ) interferometer as a quantum linear device by injecting two-mode squeezed input states into two ports of interferometer. Two-mode squeezed states can be changed into two types of inputs for MZ interferometer: two squeezed states and Einstein–Podolsky–Rosen (EPR) entangled states. The interference patterns of the MZ interferometer vary periodically as the relative phase of the two arms of the interferometer is scanned, and are measured by the balanced homodyne detection system. Our experiments show that there are different interference patterns and periodicity of the output quantum states for two cases which depend on the relative phase of input optical fields. Since MZ interferometer can be used to realize some quantum operations, this work will have the important applications in quantum information and metrology.
Abstract The phase sensitivity of a Mach–Zehnder (MZ) interferometer with a two-mode squeezed vacuum (TMSV) probe state is studied. At the initial stage, the TMSV state is deterministically converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted via photon-number resolving measurement in auxiliary measurement modes. The new probe state can already demonstrate gain sensitivity of more than 20 dB with input squeezing of 5 dB and follow Heisenberg scaling. The phase sensitivity of the MZ interferometer, estimated by measuring the intensity difference of two measurement-induced continuous variable states, can surpass the ultimate one with SMSV probe states, at least, with squeezing less than 5 dB. In general, the strategy with preliminary subtraction of photons significantly increases the estimate potential of weakly squeezed states as the probe in MZ phase-dependent interferometry; in particular, it is more effective compared to generating highly squeezed TMSV states or SMSV states.
Compared to classical state inputs, using quantum states in interferometers, especially squeezed states, can greatly improve the accuracy of the phase estimation. Here, we propose a scheme based on a Mach-Zehnder interferometer with a displaced two-mode squeezed coherent state input. The scheme employs both intensity difference detection and balanced homodyne detection to achieve high phase sensitivity. The displaced squeezed state exhibits higher accuracy and better robustness by theoretical calculations. For the state, the phase sensitivity of the quantum Cramér-Rao bound and intensity difference detection both exceed the shot noise limit. Additionally, we demonstrate that the proposed state is superior to the two-mode squeezed coherent state by analyzing different displacement operations. Under the presence of both the interferometric transmission loss and the detection loss, higher displacement strength yields higher robustness. To the best of our knowledge, our work provides new ideas for the field of precision measurement.
Abstract Choice of the quantum probe state is of key importance to enhance the sensitivity of the Mach–Zehnder (MZ) interferometer beyond the classical one and even approach the quantum Cramér–Rao bound. According to the work of Caves (Caves 1981 Phys. Rev. D 23 1693), the quantum MZ interferometer is a phase-dependent one operating with single-mode squeezed vacuum (SMSV) light coupled with a coherent state. We use the SMSV state with squeezing <10 dB and report a gain in sensitivity of the phase-dependent MZ interferometer of more than 10 dB compared to the original result (Pezze and Smerzi 2008 Phys. Rev. Lett. 100 073601) via photon subtraction. The gain in sensitivity is also observed when measuring the difference in output intensities of the SMSV state with squeezing of < 3 dB from which two, four, and six photons are subtracted and a large coherent state. Overall, subtracting photons from the initially weakly squeezed light can prove to be a more efficient strategy in quantum MZ interferometry compared to highly squeezed SMSV state generation.
Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.