Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics & Laser Technology

Optical simulation of an ultra-sensitive thermometer based on atom interferometry

Bowen Xu, Shuyu Zhou, Changhe Zhou

Published Jan 22, 2024• 0 citations
Publisher
DOI
10.1016/j.optlastec.2024.110632

Related papers

An Atom Interferometer as a Thermometer

Markus K Oberthaler, C. L. Webb, R. M. Godun +4 more

Springer eBooks•Jan 1, 1999•1 citation

Ultra-Sensitive Two-Dimensional Integrated Quantum Thermometer Module Based on the Optical Detection of Magnetic Resonance Using Nitrogen-Vacancy Centers

Ranran Xü, Zichuan Zhang, Baixi Du +3 more

In this paper, we propose a two-dimensional thermometer module based on the Nitrogen-Vacancy (NV) centers in diamonds. The thermometer integrates four modules on one Printed Circuit Board (PCB) including a laser module and a corresponding voltage regulator circuit, a microwave module, a focusing module, and an acquisition module, and it has a constructed area of 6.4${\textit {cm}}^{{2}}$. In the process of integrating equipment, we made a signal amplifier module to improve the signal-to-noise ratio (SNR). Through the amplifier module, we realize a$\sim 25$-fold increase in the fluorescence, and it successfully improved the SNR by$\sim 8.9$-fold. Fixed Frequency Optical Detection of Magnetic Resonance (FF-ODMR) measures the relationship between temperature (T) and photoluminescence (PL) by scanning the temperature field at 2.84GHz. Which is the most direct display of the thermometer. We developed an algorithm for analyzing the thermometer sensitivity based on PL the SNR analysis. The thermometer temperature-field sensitivity of approximately${19}\textit {nk}/{\textit {Hz}}^{{1}/{2}}$.

IEEE Sensors Journal•May 18, 2022•15 citations

Universal atom interferometry simulator for precision sensing

Florian Fitzek, Jan-Niclas Kirsten-Siemß, Stefan J. Seckmeyer +4 more

Bulletin of the American Physical Society•Jun 3, 2021•0 citations

Effects related to the temperature of atoms in an atom interferometry gravimeter based on ultra-cold atoms

Heng Zhang, Xudong Ren, Wenhua Yan +6 more

The temperature of atoms, coupled to several effects, plays an important role in high precision atom interferometry gravimeters. In this work, we present an ultra-cold 87Rb atom interferometry gravimeter, in which the atom source is produced by evaporative cooling in an all optical dipole trap to investigate the effects related to atom temperature. A condensate containing 4 × 104 atoms can be prepared within 3.2 s through an all-optical dipole trap composed of two reservoirs and a dimple. The fringe contrast of our atom interferometry gravimeter reaches up to 76(4)% due to the advantage of ultra-cold atom source even at a free evolution time of T=80 ms. A resolution of 6 μGal (1 μGal=1×10−8 m/s2) after 3000 s integration time with a sampling rate of 0.25 Hz is achieved in this atom gravimeter. The relationship between the fringe contrast and the atom temperature in the atom gravimeter is studied; in addition, the wavefront aberration effect in the atom gravimeter is also investigated by varying the temperature of atoms.

Optics Express•Aug 27, 2021•17 citations

Simulations of a multi-level atom interferometer

B. Barrett, I. Y. Chan, Carson Mok +4 more

APS•Mar 1, 2010•0 citations

Circulating pulse cavity enhancement as a method for extreme momentum transfer atom interferometry

Rustin Nourshargh, Samuel Lellouch, Sam Hedges +3 more

Abstract Large-scale atom interferometers promise unrivaled strain sensitivity to mid-band gravitational waves, and will probe a new parameter space in the search for ultra-light scalar dark matter. These proposals require gradiometry with kilometer-scale baselines, a momentum separation above 104ℏk between interferometer arms, and optical transitions to long-lived clock states to reach the target sensitivities. Prohibitively high optical power and wavefront flatness requirements have thus far limited the maximum achievable momentum splitting. Here we propose a scheme for optical cavity enhanced atom interferometry, using circulating, spatially resolved pulses, and intracavity frequency modulation to meet these requirements. We present parameters for the realization of 20 kW circulating pulses in a 1 km interferometer enabling 104ℏk splitting on the 698 nm clock transition in 87Sr. This scheme addresses the presently insurmountable laser power requirements and is feasible in the context of a kilometer-scale atom interferometer facility.

arXiv:2012.06426•Communications Physics•Dec 2, 2021•21 citations
In this paper, we propose a two-dimensional thermometer module based on the Nitrogen-Vacancy (NV) centers in diamonds. The thermometer integrates four modules on one Printed Circuit Board (PCB) including a laser module and a corresponding voltage regulator circuit, a microwave module, a focusing module, and an acquisition module, and it has a constructed area of 6.4cm2{\textit {cm}}^{{2}}cm2. In the process of integrating equipment, we made a signal amplifier module to improve the signal-to-noise ratio (SNR). Through the amplifier module, we realize a∼25\sim 25∼25-fold increase in the fluorescence, and it successfully improved the SNR by∼8.9\sim 8.9∼8.9-fold. Fixed Frequency Optical Detection of Magnetic Resonance (FF-ODMR) measures the relationship between temperature (T) and photoluminescence (PL) by scanning the temperature field at 2.84GHz. Which is the most direct display of the thermometer. We developed an algorithm for analyzing the thermometer sensitivity based on PL the SNR analysis. The thermometer temperature-field sensitivity of approximately19nk/Hz1/2{19}\textit {nk}/{\textit {Hz}}^{{1}/{2}}19nk/Hz1/2.
The temperature of atoms, coupled to several effects, plays an important role in high precision atom interferometry gravimeters. In this work, we present an ultra-cold 87Rb atom interferometry gravimeter, in which the atom source is produced by evaporative cooling in an all optical dipole trap to investigate the effects related to atom temperature. A condensate containing 4 × 104 atoms can be prepared within 3.2 s through an all-optical dipole trap composed of two reservoirs and a dimple. The fringe contrast of our atom interferometry gravimeter reaches up to 76(4)% due to the advantage of ultra-cold atom source even at a free evolution time of T=80 ms. A resolution of 6 μGal (1 μGal=1×10−8 m/s2) after 3000 s integration time with a sampling rate of 0.25 Hz is achieved in this atom gravimeter. The relationship between the fringe contrast and the atom temperature in the atom gravimeter is studied; in addition, the wavefront aberration effect in the atom gravimeter is also investigated by varying the temperature of atoms.
Abstract Large-scale atom interferometers promise unrivaled strain sensitivity to mid-band gravitational waves, and will probe a new parameter space in the search for ultra-light scalar dark matter. These proposals require gradiometry with kilometer-scale baselines, a momentum separation above 104ℏk between interferometer arms, and optical transitions to long-lived clock states to reach the target sensitivities. Prohibitively high optical power and wavefront flatness requirements have thus far limited the maximum achievable momentum splitting. Here we propose a scheme for optical cavity enhanced atom interferometry, using circulating, spatially resolved pulses, and intracavity frequency modulation to meet these requirements. We present parameters for the realization of 20 kW circulating pulses in a 1 km interferometer enabling 104ℏk splitting on the 698 nm clock transition in 87Sr. This scheme addresses the presently insurmountable laser power requirements and is feasible in the context of a kilometer-scale atom interferometer facility.