Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically-induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Atom interferometers with long baselines are envisioned to complement the ongoing search for dark matter. They rely on atomic manipulation based on internal (clock) transitions or state-preserving atomic diffraction. Principally, dark matter can act on the internal as well as the external degrees of freedom to both of which atom interferometers are susceptible. We, therefore, study in this contribution the effects of dark matter on the internal atomic structure and the atom’s motion. In particular, we show that the atomic transition frequency depends on the mean coupling and the differential coupling of the involved states to dark matter, scaling with the unperturbed atomic transition frequency and the Compton frequency, respectively. The differential coupling is only of relevance when internal states change, which makes detectors, e.g., based on single-photon transitions sensitive to both coupling parameters. For sensors generated by state-preserving diffraction mechanisms like Bragg diffraction, the mean coupling modifies only the motion of the atom as the dominant contribution. Finally, we compare both effects observed in terrestrial dark-matter detectors.
Atom interferometers with long baselines are envisioned to complement the ongoing search for dark matter. They rely on atomic manipulation based on internal (clock) transitions or state-preserving atomic diffraction. Principally, dark matter can act on the internal as well as the external degrees of freedom to both of which atom interferometers are susceptible. We, therefore, study in this contribution the effects of dark matter on the internal atomic structure and the atom's motion. In particular, we show that the atomic transition frequency depends on the mean coupling and the differential coupling of the involved states to dark matter, scaling with the unperturbed atomic transition frequency and the Compton frequency, respectively. The differential coupling is only of relevance when internal states change, which makes detectors, e.g., based on single-photon transitions sensitive to both coupling parameters. For sensors generated by state-preserving diffraction mechanisms like Bragg diffraction, the mean coupling modifies only the motion of the atom as the dominant contribution. Finally, we compare both effects observed in terrestrial dark-matter detectors.
Atomic interference experiments can probe the gravitational redshift via the internal energy splitting of atoms and thus give direct access to test the universality of the coupling between matter-energy and gravity at different spacetime points. By including possible violations of the equivalence principle in a fully quantized treatment of all atomic degrees of freedom, we characterize how the sensitivity to gravitational redshift violations arises in atomic clocks and atom interferometers, as well as their underlying limitations. Specifically, we show that: (i) Contributions beyond linear order to trapping potentials lead to such a sensitivity of trapped atomic clocks. (ii) Bragg-type interferometers, even with a superposition of internal states, with state-independent, linear interaction potentials are at first insensitive to gravitational redshift tests. However, modified configurations, for example by relaunching the atoms, can mimic such tests under certain conditions and may constitute a competitive alternative. (iii) Guided atom interferometers are comparable to atomic clocks. (iv) Internal transitions lead to state-dependent interaction potentials through which light-pulse atom interferometers can become sensitive to gravitational redshift violations.
This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 Atom Interferometry for Detection of Gravitational Waves project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket