Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Towards a Sr Optical Lattice Clock at ROA : First implementations

Héctor Álvarez Martínez, Antonio Estarellas Perales, Ignacio Cortés Delgado, Jesús Romero González, José Manuel Suárez Ramírez de Arellano, Verónica Bazán Suárez, Juan Manuel González Sánchez, Jaime Cafranga Bohórquez, Carmen Vélez, Héctor Esteban Pinillos, Jesús Romero González, Rodolphe Le Targat

Published May 15, 2023• 0 citations
Publisher

Abstract

SummaryWe present an overview of recent implementations achieved on the ongoing Spanish project for the construction of a stationary strontium optical lattice clock at ROA for frequency metrology
DOI
10.1109/eftf/ifcs57587.2023.10272210

Related papers

Precision frequency metrology with optical lattice clocks

William Bowden

Strontium optical lattice clocks are proven to be excellent timekeepers. Their exceptional performance makes them a leading candidate for possible redefinition of the SI second and a valuable tool for searching for new physics beyond the standard model. This thesis reports on the development of strontium (Sr) optical lattice clocks at National Physical Laboratory (NPL).

•Jan 1, 2019•0 citations

Frequency comparisons of Sr, Yb, and Hg based optical lattice clocks and their applications

Hidetoshi Katori, Ichiro Ushijima, Manoj Das +8 more

We report recent progress of optical lattice clocks with strontium, ytterbium and mercury atoms with an emphasis on their synchronous frequency comparison inside a laboratory and inter-laboratories connected by a phase-stabilized fiber link.

Conference on Lasers and Electro-Optics•Jan 1, 2015•1 citation

An optical lattice clock with strontium atoms

Mathilde Fouché, Rodolphe Le Targat, Anders Brusch +2 more

We report the preliminary operation of an optical lattice clock with Sr atoms. We describe a novel method for loading the lattice and report an optical resonance of width 260 Hz.

Conference on Lasers and Electro-Optics•Jan 1, 2006•1 citation

OPTICAL LATTICE CLOCK: SEVEN YEARS OF PROGRESS AND NEXT STEPS

Hidetoshi Katori, Masao Takamoto, Tomoya Akatsuka

We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Towards a strontium based stationary optical lattice clock

Qasim Hassan Ubaid

Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.

•Jul 20, 2020•0 citations

An optical lattice clock with neutral strontium

Richard Hobson

Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.

•Jan 1, 2016•9 citations
We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.
Optical atomic clocks have proven to be the most stable clocks with the lowest systematic uncertainty which has now reached a record level of (9.4 X10/(^{19}/)). Thus optical clocks now surpass the best fountain Cs atomic clocks by three orders of magnitude which opens the prospect of using optical clocks as frequency standards for timekeeping in the near future. \n \nThis thesis describes the progress that has been made towards a stationary optical lattice clock based on strontium atoms, and reports the results of an ongoing characterization. \n \nAn experimental apparatus was designed and built to efficiently slow, cool, and trap the strontium atoms which represent the heart of the strontium optical lattice clock discussed in this thesis. The novel aspects of the experimental development described in the thesis comprise a frequency doubling cavity for producing 461 nm laser light employed for cooling and trapping the strontium atoms in the first stage cooling. This cavity provided sufficient power for cooling and trapping the strontium atoms for up to 300 mW of 461 nm laser light. Furthermore, a new design of Zeeman slower based on spherical permanent magnets was produced, built and characterized. \n \nThe slower is compact, tunable, easy to assemble and maintain, and cost-effective as the permanent magnets do not require any power supply or water cooling. It is suggested that this kind of Zeeman slower constitutes an ideal solution for portable optical clock systems. A blue magneto-optical trap was realized for the first time with such a Zeeman slower. With about 30 mW of a 461 nm laser, up to 6X10/(^8/) atoms were captured.
Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.