Phase sensitivity with a coherent beam and twin beams via intensity difference detection

Jun Liu, Tao Shao, Chenlu Li, Minyang Zhang, Youyou Hu, Dongxu Chen, Dong 栋 Wei 卫

Published Oct 7, 2023• 6 citations
Publisher

Abstract

We focus on the Mach–Zehnder interferometer (MZI) with the input of a coherent beam and one of the bright entangled twin beams with an external power reference beam employed for measurement. The results show that the phase sensitivity can reach sub-Heisenberg limit and approach quantum Cramér–Rao bound by changing the squeezing parameters and the photon number of the coherent beam, under the phase-matching condition. The absence of the external power reference beam will degrade the performance of the phase sensitivity. Meanwhile, this scheme shows good robustness against the losses of the photon detectors. We present a detailed discussion about the phase sensitivities when the inputs are two coherent beams, or a coherent beam plus a single-mode squeezed vacuum beam based on the MZI. This scenario can be applied in the field of phase precision measurements and other optical sensors.

DOI
10.1088/1674-1056/ad0115

Related papers

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•13 citations

Optimal phase sensitivity by quantum squeezing based on a Mach–Zehnder interferometer

Jun Liu, Ya Yu, Chengyuan Wang +6 more

Abstract A novel scheme for the enhancement of phase sensitivity based on a Mach–Zehnder interferometer (MZI) and intensity detection is proposed. With the input of bright entangled twin beams from four wave mixing (FWM), the phase sensitivity can beat shot noise limit (SNL) and approach Heisenberg limit. This scheme is special due to that only one of bright entangled twin beams enters into the MZI and the other one is employed for measurement. In addition, by altering the parametric strength of FWM and the implementation of maximum quantum squeezing, the optimal phase sensitivity can reach sub-SNL. Optical intensity depletion of photon detectors and internal intensity depletion of the MZI are also discussed. The scheme displays that by employing external resources, while one input of the MZI is an vacuum beam, the phase sensitivity still can beat SNL.

New Journal of Physics•Dec 18, 2019•22 citations

High-sensitivity phase estimation with a two-mode squeezed coherent state based on a Mach–Zehnder interferometer

Pengxiang Ruan, Jun Liu, Chenlu Li +3 more

Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.

Chinese Physics B•Jul 28, 2025•0 citations

Phase sensitivity of a Mach-Zehnder interferometer with single-intensity and difference-intensity detection

Stefan Ataman, Anca Preda, Radu Ionicioiu

Interferometry is a widely used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example, in a Mach-Zehnder interferometer (MZI), is to use high-intensity lasers. In this paper we study the phase sensitivity of a MZI in two detection setups (difference intensity detection and single-mode intensity detection) and for three input scenarios (coherent, double coherent, and coherent plus squeezed vacuum). For the coherent and double coherent input, both detection setups can reach the quantum Cram\'er-Rao bound, although at different values of the optimal phase shift. The double coherent input scenario has the unique advantage of changing the optimal phase shift by varying the input power ratio.

arXiv:1811.02412•Physical Review A•Oct 30, 2018•64 citations

Deterministic sub-Heisenberg limit phase sensitivity with the squeezed coherent state via balanced homodyne detection

Chenlu Li, Shaoqiu Ke, Pengxiang Ruan +5 more

Abstract We investigate the phase sensitivities of three schemes with the input of the squeezed coherent states based on the Mach–Zehnder interferometer (MZI). With employing the balanced homodyne detection, the phase sensitivities of these schemes can surpass the shot noise limit (SNL) and reach the sub-Heisenberg limit. By adjusting the combination of the squeezing parameter and the photon number of the coherent state, both the phase sensitivities with using the balanced homodyne detection and the quantum Cramer–Rao bound can be improved. In the regime of low squeezing parameters, the scheme with the two-mode squeezed coherent state outperforms the other two schemes. The phase sensitivity can only reach the sub-SNL when the photon number is much larger. These schemes exhibit strong robustness against internal losses of the MZI and photon detector losses. This work will play an important role in the field of quantum precision measurement.

Physica Scripta•Feb 4, 2025•2 citations

Enhancing phase sensitivity in a Mach-Zehnder interferometer with various detection schemes using SU(1,1) coherent states

Nour-Eddine Abouelkhir, Abdallah Slaoui, El Hassan Saidi +2 more

Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.

arXiv:2406.08007•Journal of the Optical Society of America B•Dec 23, 2024•14 citations
We focus on the Mach–Zehnder interferometer (MZI) with the input of a coherent beam and one of the bright entangled twin beams with an external power reference beam employed for measurement. The results show that the phase sensitivity can reach sub-Heisenberg limit and approach quantum Cramér–Rao bound by changing the squeezing parameters and the photon number of the coherent beam, under the phase-matching condition. The absence of the external power reference beam will degrade the performance of the phase sensitivity. Meanwhile, this scheme shows good robustness against the losses of the photon detectors. We present a detailed discussion about the phase sensitivities when the inputs are two coherent beams, or a coherent beam plus a single-mode squeezed vacuum beam based on the MZI. This scenario can be applied in the field of phase precision measurements and other optical sensors.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
Abstract A novel scheme for the enhancement of phase sensitivity based on a Mach–Zehnder interferometer (MZI) and intensity detection is proposed. With the input of bright entangled twin beams from four wave mixing (FWM), the phase sensitivity can beat shot noise limit (SNL) and approach Heisenberg limit. This scheme is special due to that only one of bright entangled twin beams enters into the MZI and the other one is employed for measurement. In addition, by altering the parametric strength of FWM and the implementation of maximum quantum squeezing, the optimal phase sensitivity can reach sub-SNL. Optical intensity depletion of photon detectors and internal intensity depletion of the MZI are also discussed. The scheme displays that by employing external resources, while one input of the MZI is an vacuum beam, the phase sensitivity still can beat SNL.
Abstract A scheme is proposed based on a Mach–Zehnder interferometer with high phase sensitivity, utilizing a two-mode squeezed coherent state, generated by four-wave mixing, as input. The phase sensitivity of this scheme easily surpasses the Heisenberg limit when intensity difference detection is applied. Under phase-matching conditions, the quantum Cramér–Rao bound significantly exceeds the Heisenberg limit. Additionally, the scheme exhibits robustness against photon loss. When compared with the modified SU(1,1) interferometer with two coherent state inputs, this approach demonstrates superior measurement sensitivity, evaluated through various detection methods and the quantum Cramér–Rao bound. This work holds potential applications in quantum metrology.
Interferometry is a widely used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example, in a Mach-Zehnder interferometer (MZI), is to use high-intensity lasers. In this paper we study the phase sensitivity of a MZI in two detection setups (difference intensity detection and single-mode intensity detection) and for three input scenarios (coherent, double coherent, and coherent plus squeezed vacuum). For the coherent and double coherent input, both detection setups can reach the quantum Cram\'er-Rao bound, although at different values of the optimal phase shift. The double coherent input scenario has the unique advantage of changing the optimal phase shift by varying the input power ratio.
Abstract We investigate the phase sensitivities of three schemes with the input of the squeezed coherent states based on the Mach–Zehnder interferometer (MZI). With employing the balanced homodyne detection, the phase sensitivities of these schemes can surpass the shot noise limit (SNL) and reach the sub-Heisenberg limit. By adjusting the combination of the squeezing parameter and the photon number of the coherent state, both the phase sensitivities with using the balanced homodyne detection and the quantum Cramer–Rao bound can be improved. In the regime of low squeezing parameters, the scheme with the two-mode squeezed coherent state outperforms the other two schemes. The phase sensitivity can only reach the sub-SNL when the photon number is much larger. These schemes exhibit strong robustness against internal losses of the MZI and photon detector losses. This work will play an important role in the field of quantum precision measurement.
Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.