Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Characterizing quantum states of light using ghost imaging

Xiaolong Dong, Dongyu Liu, Mingsheng Tian, Shuheng Liu, Yi Li, T. Y. Hu, Qiongyi He, Haitan Xu, Zheng Li

Published Oct 2, 2023• 4 citations
Publisher

Abstract

Ghost imaging can be implemented with illumination light with pronounced quantum characters. In this work, we address the inverse problem of ghost imaging, i.e., the tomography of the quantum states of illumination light based on ghost imaging. We showcase the characterization of multimode Gaussian state light represented by its covariance matrix. With the information of spatial modes, we reconstruct the quantum states of light using the variation of SNR of the ghost images formed by the input light under a given set of optical operations. We demonstrate that ghost imaging can also be used to characterize the non-Gaussian light by its deviation from Gaussian states, which can serve as a criterion for the non-Gaussianity of the input light. The spatial resolving power of the proposed method can be advantageous for quantum information applications involving structured light, such as multiplexing with spatial modes.

DOI
10.1103/physrevapplied.20.044001

Related papers

Ghost Imaging with Non-Gaussian Quantum Light

Dongyu Liu, Mingsheng Tian, Shuheng Liu +5 more

Nonlocal point-to-point correlations between two photons have been used to produce ``ghost'' images without placing the camera towards the object. Here we theoretically demonstrate and analyze the advantage of non-Gaussian quantum light in improving the image quality of a ghost imaging system over a traditional Gaussian light source. For any squeezing degree, the signal-to-noise ratio (SNR) of the ghost image can be enhanced by the non-Gaussian operations of photon addition and subtraction on a two-mode squeezed light source. We find striking evidence that using non-Gaussian coherent operations, the SNR can be promoted to a high level even within the extremely weak squeezing regime. The resulting insight provides experimental recipes of quantum imaging using non-Gaussian light for illumination.

arXiv:2106.00443•Physical Review Applied•Dec 15, 2021•16 citations

Quantum ghost imaging with a modal basis

Fazilah Nothlawala, Chané Moodley, Neelan Gounden +2 more

Quantum ghost imaging harnesses entangled photon pairs to form images using light that never directly interacts with the object. Conventional approaches rely on pixelated detectors or spatial masks, where the resolution is fundamentally limited by the pixel size and thus bounded by the Rayleigh criterion. In this work, we present a modal approach that replaces pixel-based detection with measurements in a basis of structured modes. By reconstructing images through tailored spatial modes, we decouple resolution from the physical limitations of detectors and instead tie it to the system’s optical precision and computational control. We demonstrate that even non-orthogonal modal sets can achieve high fidelity image reconstruction by exploiting modal sparsity, significantly reducing the number of required measurements. Using phase-only approximations of Hermite-Gaussian modes, we avoid the loss associated with complex amplitude modulation while retaining high reconstruction fidelity. The result is a high-resolution, high-efficiency quantum ghost imaging technique powered by structured light, opening new possibilities for photon-efficient imaging in low-light and quantum-limited regimes, such as biological microscopy and remote sensing.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Reduction of Multiplexed Quantum Ghost Images

Dmitriy A. Balakin, Aleksandr V. Belinsky

Ghost imaging allows extracting information about an object from the spatial correlation function between the photons that interacted with an object and the photons in the reference arm(s). The reference beam does not interact with the object; however, it is measured by a CCD matrix. The mathematical method of measurement reduction allows using both the mutual correlations of multiplexed ghost images and prior information about how the image of the research object can look in order to improve the quality of the reconstructed image. The information about the object is the sparsity of its transparency distribution under a given transform. Computer modelling of image reconstruction using multiplexed ghost images formed by four-mode entangled quantum light states confirms the efficiency of the proposed algorithm even with a small number of photons that illuminate the research object.

Moscow University Physics Bulletin•Jan 1, 2019•4 citations

Nature of light correlations in ghost imaging

Sammy Ragy, Gerardo Adesso

We investigate the nature of correlations in Gaussian light sources used for ghost imaging. We adopt methods from quantum information theory to distinguish genuinely quantum from classical correlations. Combining a microscopic analysis of speckle-speckle correlations with an effective coarse-grained description of the beams, we show that quantum correlations exist even in 'classical'-like thermal light sources, and appear relevant for the implementation of ghost imaging in the regime of low illumination. We further demonstrate that the total correlations in the thermal source beams effectively determine the quality of the imaging, as quantified by the signal-to-noise ratio.

arXiv:1208.5808•Scientific Reports•Sep 12, 2012•43 citations

Quantum Ghost Imaging by Sparse Spatial Mode Reconstruction (Adv. Quantum Technol. 5/2025)

Fazilah Nothlawala, Chané Moodley, Neelan Gounden +2 more

In article number 2400577, Andrew Forbes and co-workers achieved high resolution, time-efficient quantum ghost imaging by leveraging structured light and spatial modes as a basis for imaging, paving the way for breakthroughs in low-light, biological science applications. The cover represents an object — the ghost — whose image is revealed through spatial mode projections.

Advanced Quantum Technologies•May 1, 2025•0 citations

Improvement of the optical image reconstruction based on multiplexed quantum ghost images

Dmitriy A. Balakin, Aleksandr V. Belinsky, A. S. Chirkin

Ghost imaging allows one to obtain information on an object from the spatial correlation function between photons propagating through or reflected from the object and photons of the reference arm. In this case, detection in the object arm is performed over the entire aperture of the beam and, therefore, it does not give information on the object. The reference beam does not interact with the object, but is recorded with a scanning point detector or a CCD array permitting the measurement of the spatial correlation function of photons in two arms. The use of multimode entangled quantum light beams by illuminating the object by one beam and orienting other beams to reference arms makes it possible to obtain simultaneously several ghost images (GIs). Cross correlations of multiplexed GIs (MGIs) are determined by eighth-order field correlation functions. A special algorithm is developed for calculating higher-order correlations of Bose operators. The presence of GI cross correlations is used for improving the quality of the reconstructed object’s image by their processing using the measurement reduction method. An example of the computer simulation of the image reconstruction by MGIs formed in the field of four-frequency entangled quantum states is considered. It is found that in this case the reduced GI has a signal-to-noise ratio several times higher than that of GIs.

Journal of Experimental and Theoretical Physics•Aug 1, 2017•12 citations
Ghost imaging can be implemented with illumination light with pronounced quantum characters. In this work, we address the inverse problem of ghost imaging, i.e., the tomography of the quantum states of illumination light based on ghost imaging. We showcase the characterization of multimode Gaussian state light represented by its covariance matrix. With the information of spatial modes, we reconstruct the quantum states of light using the variation of SNR of the ghost images formed by the input light under a given set of optical operations. We demonstrate that ghost imaging can also be used to characterize the non-Gaussian light by its deviation from Gaussian states, which can serve as a criterion for the non-Gaussianity of the input light. The spatial resolving power of the proposed method can be advantageous for quantum information applications involving structured light, such as multiplexing with spatial modes.
Nonlocal point-to-point correlations between two photons have been used to produce ``ghost'' images without placing the camera towards the object. Here we theoretically demonstrate and analyze the advantage of non-Gaussian quantum light in improving the image quality of a ghost imaging system over a traditional Gaussian light source. For any squeezing degree, the signal-to-noise ratio (SNR) of the ghost image can be enhanced by the non-Gaussian operations of photon addition and subtraction on a two-mode squeezed light source. We find striking evidence that using non-Gaussian coherent operations, the SNR can be promoted to a high level even within the extremely weak squeezing regime. The resulting insight provides experimental recipes of quantum imaging using non-Gaussian light for illumination.
Quantum ghost imaging harnesses entangled photon pairs to form images using light that never directly interacts with the object. Conventional approaches rely on pixelated detectors or spatial masks, where the resolution is fundamentally limited by the pixel size and thus bounded by the Rayleigh criterion. In this work, we present a modal approach that replaces pixel-based detection with measurements in a basis of structured modes. By reconstructing images through tailored spatial modes, we decouple resolution from the physical limitations of detectors and instead tie it to the system’s optical precision and computational control. We demonstrate that even non-orthogonal modal sets can achieve high fidelity image reconstruction by exploiting modal sparsity, significantly reducing the number of required measurements. Using phase-only approximations of Hermite-Gaussian modes, we avoid the loss associated with complex amplitude modulation while retaining high reconstruction fidelity. The result is a high-resolution, high-efficiency quantum ghost imaging technique powered by structured light, opening new possibilities for photon-efficient imaging in low-light and quantum-limited regimes, such as biological microscopy and remote sensing.
Ghost imaging allows extracting information about an object from the spatial correlation function between the photons that interacted with an object and the photons in the reference arm(s). The reference beam does not interact with the object; however, it is measured by a CCD matrix. The mathematical method of measurement reduction allows using both the mutual correlations of multiplexed ghost images and prior information about how the image of the research object can look in order to improve the quality of the reconstructed image. The information about the object is the sparsity of its transparency distribution under a given transform. Computer modelling of image reconstruction using multiplexed ghost images formed by four-mode entangled quantum light states confirms the efficiency of the proposed algorithm even with a small number of photons that illuminate the research object.
We investigate the nature of correlations in Gaussian light sources used for ghost imaging. We adopt methods from quantum information theory to distinguish genuinely quantum from classical correlations. Combining a microscopic analysis of speckle-speckle correlations with an effective coarse-grained description of the beams, we show that quantum correlations exist even in 'classical'-like thermal light sources, and appear relevant for the implementation of ghost imaging in the regime of low illumination. We further demonstrate that the total correlations in the thermal source beams effectively determine the quality of the imaging, as quantified by the signal-to-noise ratio.
Ghost imaging allows one to obtain information on an object from the spatial correlation function between photons propagating through or reflected from the object and photons of the reference arm. In this case, detection in the object arm is performed over the entire aperture of the beam and, therefore, it does not give information on the object. The reference beam does not interact with the object, but is recorded with a scanning point detector or a CCD array permitting the measurement of the spatial correlation function of photons in two arms. The use of multimode entangled quantum light beams by illuminating the object by one beam and orienting other beams to reference arms makes it possible to obtain simultaneously several ghost images (GIs). Cross correlations of multiplexed GIs (MGIs) are determined by eighth-order field correlation functions. A special algorithm is developed for calculating higher-order correlations of Bose operators. The presence of GI cross correlations is used for improving the quality of the reconstructed object’s image by their processing using the measurement reduction method. An example of the computer simulation of the image reconstruction by MGIs formed in the field of four-frequency entangled quantum states is considered. It is found that in this case the reduced GI has a signal-to-noise ratio several times higher than that of GIs.