Review of Scientific Instruments

Sympathetically cooled highly charged ions in a radio-frequency trap with superconducting magnetic shielding

Elwin Dijck, Christian Warnecke, Malte Wehrheim, Ruben B. Henninger, Julia Eff, Kostas Georgiou, Andrea Graf, Stepan Kokh, Lakshmi Priya Kozhiparambil Sajith, Christopher Mayo, Vera M. Schäfer, Claudia Volk, Piet O. Schmidt, Thomas Pfeifer, J. R. Crespo López-Urrutia

Published Aug 1, 2023• 5 citations
Publisher

Abstract

We sympathetically cool highly charged ions (HCI) in Coulomb crystals of Doppler-cooled Be+ ions confined in a cryogenic linear Paul trap that is integrated into a fully enclosing radio-frequency resonator manufactured from superconducting niobium. By preparing a single Be+ cooling ion and a single HCI, quantum logic spectroscopy toward frequency metrology and qubit operations with a great variety of species are enabled. While cooling down the assembly through its transition temperature into the superconducting state, an applied quantization magnetic field becomes persistent, and the trap becomes shielded from subsequent external electromagnetic fluctuations. Using a magnetically sensitive hyperfine transition of Be+ as a qubit, we measure the fractional decay rate of the stored magnetic field to be at the 10-10 s-1 level. Ramsey interferometry and spin-echo measurements yield coherence times of >400 ms, demonstrating excellent passive magnetic shielding at frequencies down to DC.

DOI
10.1063/5.0160537

Related papers

Cold highly charged ions in a radio-frequency trap with superconducting magnetic shielding

Elwin Dijck, Christian Warnecke, Malte Wehrheim +12 more

We implement sympathetic cooling of highly charged ions (HCI) by fully enclosing a linear Paul trap within a superconducting radio-frequency resonator. A quantization magnetic field applied while cooling down into the superconducting state remains present in the trap for centuries and external electromagnetic fluctuations are greatly suppressed. A magnetic field decay rate at the 10$^{-10}$ s$^{-1}$ level is found using trapped Doppler-cooled Be$^+$ ions as hyperfine-structure (hfs) qubits. Ramsey interferometry and spin-echo measurements on magnetically-sensitive hfs transitions yield coherence times of >400 ms, showing excellent passive shielding at frequencies down to DC. For sympathetic cooling of HCI, we extract them from an electron beam ion trap (EBIT) and co-crystallize one together with Doppler-cooled Be$^+$ ions. By subsequently ejecting all but one Be$^+$ ions, we prepare single HCI for quantum logic spectroscopy towards frequency metrology and qubit operations with a great variety of HCI species.

arXiv:2306.01670•Review of Scientific Instruments•Jan 1, 2023•0 citations

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

Tobias Leopold, S. A. King, P. Micke +5 more

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.

•Jan 1, 2019•41 citations

A cryogenic radio-frequency ion trap for quantum logic spectroscopy of highly charged ions

T. Leopold, S. A. King, P. Micke +5 more

A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.

arXiv:1901.03082•Review of Scientific Instruments•Jul 1, 2019•50 citations

An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions

Julian Stark, Christian Warnecke, S. Bogen +17 more

We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of Q ≈ 2.3 × 105 at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts that limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron-beam ion trap, and deceleration beamline supplying highly charged ions (HCIs), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole-mass filter with HCIs and trapping of Doppler-cooled 9Be+ Coulomb crystals.

arXiv:2102.02793•Review of Scientific Instruments•Aug 1, 2021•9 citations

Coulomb crystals in a cryogenic Paul trap for sympathetic cooling of molecular ions and highly charged ions

A. Windberger, M. Schwarz, Oscar O. Versolato +11 more

Electron beam ion traps used for spectroscopy of highly charged ions (HCI) produce a deep trapping potential leading to high temperatures of the stored ions, and thus limiting the achievable spectral resolution. A novel device at the Max-Planck-Institut für Kernphysik, the Cryogenic linear Paul Trap Experiment (CryPTEx), attached to an electron beam ion trap, provides a new experimental platform to overcome these limitations. The trap assembly operates at a temperature of 4 K and offers optical access for quantum manipulation and imaging of the trapped ions. Since forbidden optical transitions in HCI do not support direct laser cooling, sympathetic cooling with Coulomb crystals of singly charged ions such as Be+ or Mg+ will be applied in order to reach the natural linewidth of optical forbidden transitions in HCI of interest. With the added advantage of long ion trapping times resulting from residual gas pressures of H2 at 4 K below 10−15 mbar, CryPTEx has been commissioned in collaboration with the Ion Trap Group in Århus using rovibrationally cooled MgH+ ions. Strong suppression of the black body radiation at the trap center, ion storage times of about 28 hours, and largely enhanced population of the rovibrational ground state were achieved.

AIP conference proceedings•Jan 1, 2013•4 citations

Setup of a vibration-suppressed cryogenic system for a RF ion trap with minimum micromotion

Lukas J. Spieß

Recent advancements allow for sympathetic cooling of highly charged ions (HCI) to mK temperatures in a cryogenic linear Paul trap. This makes high precision spectroscopy of HCI possible, paving the way to the search for new physics and novel optical clocks. For this, a highly stable and well-understood Paul trap is required. In particular, excess micromotion needs to be characterized and reduced, since it can limit the lowest achievable ion temperature and therefore spectroscopic precision. Within this thesis, a new cryogenic supply system was partly assembled, which allows for vibrational decoupling of the trap, increasing storage stability. The first cool down test achieved a temperature of 4:23K in the trap environment, which is sufficiently low for superconductive operation of the intended RF-resonator made from niobium. Additionally, a photon-correlation technique was used on the existing cryogenic linear Paul trap using 9Be+ ions for determination of the trap frequency by measuring the phase shift between the driven ions motion and the driving field. From the trap frequency the magnification of the imaging system is deduced. The same photon-correlation technique is used to measure excess micromotion and to demonstrate its reduction by a factor of 100 compared to a previous measurement by using new electronics.

•Jan 1, 2018•0 citations
We sympathetically cool highly charged ions (HCI) in Coulomb crystals of Doppler-cooled Be+ ions confined in a cryogenic linear Paul trap that is integrated into a fully enclosing radio-frequency resonator manufactured from superconducting niobium. By preparing a single Be+ cooling ion and a single HCI, quantum logic spectroscopy toward frequency metrology and qubit operations with a great variety of species are enabled. While cooling down the assembly through its transition temperature into the superconducting state, an applied quantization magnetic field becomes persistent, and the trap becomes shielded from subsequent external electromagnetic fluctuations. Using a magnetically sensitive hyperfine transition of Be+ as a qubit, we measure the fractional decay rate of the stored magnetic field to be at the 10-10 s-1 level. Ramsey interferometry and spin-echo measurements yield coherence times of >400 ms, demonstrating excellent passive magnetic shielding at frequencies down to DC.
We implement sympathetic cooling of highly charged ions (HCI) by fully enclosing a linear Paul trap within a superconducting radio-frequency resonator. A quantization magnetic field applied while cooling down into the superconducting state remains present in the trap for centuries and external electromagnetic fluctuations are greatly suppressed. A magnetic field decay rate at the 10−10^{-10}−10 s−1^{-1}−1 level is found using trapped Doppler-cooled Be+^++ ions as hyperfine-structure (hfs) qubits. Ramsey interferometry and spin-echo measurements on magnetically-sensitive hfs transitions yield coherence times of >400 ms, showing excellent passive shielding at frequencies down to DC. For sympathetic cooling of HCI, we extract them from an electron beam ion trap (EBIT) and co-crystallize one together with Doppler-cooled Be+^++ ions. By subsequently ejecting all but one Be+^++ ions, we prepare single HCI for quantum logic spectroscopy towards frequency metrology and qubit operations with a great variety of HCI species.
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.
A cryogenic radio-frequency ion trap system designed for quantum logic spectroscopy of highly charged ions (HCI) is presented. It includes a segmented linear Paul trap, an in-vacuum imaging lens, and a helical resonator. We demonstrate ground state cooling of all three modes of motion of a single 9Be+ ion and determine their heating rates as well as excess axial micromotion. The trap shows one of the lowest levels of electric field noise published to date. We investigate the magnetic-field noise suppression in cryogenic shields made from segmented copper, the resulting magnetic field stability at the ion position and the resulting coherence time. Using this trap in conjunction with an electron beam ion trap and a deceleration beamline, we have been able to trap single highly charged Ar13+ (Ar XIV) ions concurrently with single Be+ ions, a key prerequisite for the first quantum logic spectroscopy of a HCI. This major stepping stone allows us to push highly-charged-ion spectroscopic precision from the gigahertz to the hertz level and below.
We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of Q ≈ 2.3 × 105 at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts that limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron-beam ion trap, and deceleration beamline supplying highly charged ions (HCIs), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole-mass filter with HCIs and trapping of Doppler-cooled 9Be+ Coulomb crystals.
Electron beam ion traps used for spectroscopy of highly charged ions (HCI) produce a deep trapping potential leading to high temperatures of the stored ions, and thus limiting the achievable spectral resolution. A novel device at the Max-Planck-Institut für Kernphysik, the Cryogenic linear Paul Trap Experiment (CryPTEx), attached to an electron beam ion trap, provides a new experimental platform to overcome these limitations. The trap assembly operates at a temperature of 4 K and offers optical access for quantum manipulation and imaging of the trapped ions. Since forbidden optical transitions in HCI do not support direct laser cooling, sympathetic cooling with Coulomb crystals of singly charged ions such as Be+ or Mg+ will be applied in order to reach the natural linewidth of optical forbidden transitions in HCI of interest. With the added advantage of long ion trapping times resulting from residual gas pressures of H2 at 4 K below 10−15 mbar, CryPTEx has been commissioned in collaboration with the Ion Trap Group in Århus using rovibrationally cooled MgH+ ions. Strong suppression of the black body radiation at the trap center, ion storage times of about 28 hours, and largely enhanced population of the rovibrational ground state were achieved.
Recent advancements allow for sympathetic cooling of highly charged ions (HCI) to mK temperatures in a cryogenic linear Paul trap. This makes high precision spectroscopy of HCI possible, paving the way to the search for new physics and novel optical clocks. For this, a highly stable and well-understood Paul trap is required. In particular, excess micromotion needs to be characterized and reduced, since it can limit the lowest achievable ion temperature and therefore spectroscopic precision. Within this thesis, a new cryogenic supply system was partly assembled, which allows for vibrational decoupling of the trap, increasing storage stability. The first cool down test achieved a temperature of 4:23K in the trap environment, which is sufficiently low for superconductive operation of the intended RF-resonator made from niobium. Additionally, a photon-correlation technique was used on the existing cryogenic linear Paul trap using 9Be+ ions for determination of the trap frequency by measuring the phase shift between the driven ions motion and the driving field. From the trap frequency the magnification of the imaging system is deduced. The same photon-correlation technique is used to measure excess micromotion and to demonstrate its reduction by a factor of 100 compared to a previous measurement by using new electronics.