Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Results in Physics

Efficacy of differential phase extraction methods in dual atom interferometers under correlated noise conditions

Huai-Yu Zhu, Ming Xue, Jinbin Li, Min Deng

Published Aug 17, 2023• 3 citations
Publisher

Abstract

Atom interferometry-based sensors have demonstrated remarkable precision, making them attractive for diverse applications compared to traditional sensors. However, practical experiments inevitably encounter noise, which limits precision. We investigate the performance of two commonly used methods, ellipse fitting (EF) and fringe fitting (FF), for differential phase estimation in a dual atom interferometer under various noise conditions. We comprehensively analyze the efficacy of these methods for each type of Gaussian noise, including phase noise, amplitude noise, and offset noise. Using a colored noise model, we investigate the Allan deviation results. Our investigations will offer valuable insights for future quantum sensing based on dual interferometers.

DOI
10.1016/j.rinp.2023.106855

Related papers

An investigation of errors in ellipse-fitting for cold-atom interferometers

Kevin D. Ridley, Anthony Rodgers

Abstract Ellipse fitting is a technique which is used to extract differential phase in cold-atom interferometers, particularly in situations where common-mode noise needs to be suppressed. We use numerical simulation to investigate errors in the ellipse fitting process; specifically, errors due to the presence of additive noise, linear drift in ellipse offset and amplitude, as well as an error that can arise from fringe normalisation. Errors are found to manifest in two ways: bias in the ellipse phase measurement and incomplete suppression of common mode phase noise. We quantify these errors for three different ellipse fitting algorithms and discuss the applicability of these results to future cold atom sensors.

EPJ Quantum Technology•Nov 22, 2024•3 citations

Squeezing-enhanced accurate differential sensing under large phase noise

Robin Corgier, Marco Malitesta, Leonid A. Sidorenkov +6 more

Atom interferometers are reaching sensitivities fundamentally constrained by quantum fluctuations. A main challenge is to integrate entanglement into quantum sensing protocols to enhance precision while ensuring robustness against noise and systematics. Here, we theoretically investigate differential phase measurements with two atom interferometers using spin-squeezed states, accounting for common-mode phase noise spanning the full $2π$ range. We estimate the differential signal using model-free ellipse fitting, a robust method requiring no device calibration and resilient to additional noise sources. Our results show that spin-squeezing enables sensitivities below the standard quantum limit. Specifically, we identify optimal squeezed states that minimize the differential phase variance, scaling as $N^{-2/3}$, while eliminating bias inherent in ellipse fitting methods. We benchmark our protocol against the Cramér-Rao bound and compare it with hybrid methods that incorporate auxiliary classical sensors. Our findings provide a pathway to robust and high-precision atom interferometry, in realistic noisy environments and using readily available states and estimation methods.

arXiv:2501.18256•Jan 30, 2025•0 citations

Correlative methods for dual-species quantum tests of the weak equivalence principle

B. Barrett, Laura Antoni‐Micollier, Laure Chichet +5 more

Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.

arXiv:1503.08423•New Journal of Physics•Aug 27, 2015•64 citations

Dependence of the ellipse fitting noise on the differential phase between interferometers in atom gravity gradiometers

Xiaowei Zhang, Jiaqi Zhong, Wei Lyu +7 more

Ellipse fitting is widely used in the extraction of the differential phase between atom interferometers amid substantial common phase noise. This study meticulously examines the dependency of extraction noise on the differential phase between atom interferometers during ellipse fitting. It reveals that the minimum extraction noise can manifest at distinct differential phases, contingent upon the dominance of different noise types. Moreover, the outcomes are influenced by whether the interferometers undergo simultaneous detection or not. Our theoretical simulations find empirical validation in a compact horizontal atom gravity gradiometer. The adjustment of the differential phase significantly enhances measurement sensitivity, culminating in a differential gravity resolution of 1.6 × 10−10 g @ 4800 s.

Optics Express•Dec 1, 2023•4 citations

Optimized squeezing for accurate differential sensing under large phase noise

Robin Corgier, Marco Malitesta, Leonid A. Sidorenkov +6 more

Abstract Atom interferometers are reaching sensitivities fundamentally constrained by quantum fluctuations. A main challenge is to integrate entanglement into quantum sensing protocols to enhance precision while ensuring robustness against noise and systematics. Here, we theoretically investigate differential phase measurements with two atom interferometers using spin-squeezed states of N atoms, accounting for common-mode phase noise spanning the full 2 π range. We estimate the differential signal using model-free ellipse fitting, a robust method requiring no device calibration and resilient to additional noise sources. Our results show that spin-squeezing enables sensitivities below the standard quantum limit (SQL). Specifically, we identify optimal squeezed states that minimize the differential phase uncertainty, scaling as N − 2 / 3 , thus overcoming the SQL by a factor N 1 / 6 , while eliminating the bias inherent in ellipse fitting methods. We benchmark our protocol against the Cramér–Rao bound and compare it with hybrid methods that incorporate auxiliary classical sensors. Our findings provide a pathway to robust and high-precision atom interferometry, in realistic noisy environments and using readily available states and estimation methods.

Quantum Science and Technology•Jul 22, 2025•5 citations

Differential phase extraction in dual interferometers exploiting the correlation between classical and quantum sensors

Mehdi Langlois, Romain Caldani, Azer Trimeche +2 more

We perform the experimental demonstration of the method proposed earlier [F. P. Dos Santos, Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.

arXiv:1712.02071•Physical Review A•Nov 20, 2017•18 citations
Atom interferometry-based sensors have demonstrated remarkable precision, making them attractive for diverse applications compared to traditional sensors. However, practical experiments inevitably encounter noise, which limits precision. We investigate the performance of two commonly used methods, ellipse fitting (EF) and fringe fitting (FF), for differential phase estimation in a dual atom interferometer under various noise conditions. We comprehensively analyze the efficacy of these methods for each type of Gaussian noise, including phase noise, amplitude noise, and offset noise. Using a colored noise model, we investigate the Allan deviation results. Our investigations will offer valuable insights for future quantum sensing based on dual interferometers.
Abstract Ellipse fitting is a technique which is used to extract differential phase in cold-atom interferometers, particularly in situations where common-mode noise needs to be suppressed. We use numerical simulation to investigate errors in the ellipse fitting process; specifically, errors due to the presence of additive noise, linear drift in ellipse offset and amplitude, as well as an error that can arise from fringe normalisation. Errors are found to manifest in two ways: bias in the ellipse phase measurement and incomplete suppression of common mode phase noise. We quantify these errors for three different ellipse fitting algorithms and discuss the applicability of these results to future cold atom sensors.
Atom interferometers are reaching sensitivities fundamentally constrained by quantum fluctuations. A main challenge is to integrate entanglement into quantum sensing protocols to enhance precision while ensuring robustness against noise and systematics. Here, we theoretically investigate differential phase measurements with two atom interferometers using spin-squeezed states, accounting for common-mode phase noise spanning the full 2π2π2π range. We estimate the differential signal using model-free ellipse fitting, a robust method requiring no device calibration and resilient to additional noise sources. Our results show that spin-squeezing enables sensitivities below the standard quantum limit. Specifically, we identify optimal squeezed states that minimize the differential phase variance, scaling as N−2/3N^{-2/3}N−2/3, while eliminating bias inherent in ellipse fitting methods. We benchmark our protocol against the Cramér-Rao bound and compare it with hybrid methods that incorporate auxiliary classical sensors. Our findings provide a pathway to robust and high-precision atom interferometry, in realistic noisy environments and using readily available states and estimation methods.
Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.
Ellipse fitting is widely used in the extraction of the differential phase between atom interferometers amid substantial common phase noise. This study meticulously examines the dependency of extraction noise on the differential phase between atom interferometers during ellipse fitting. It reveals that the minimum extraction noise can manifest at distinct differential phases, contingent upon the dominance of different noise types. Moreover, the outcomes are influenced by whether the interferometers undergo simultaneous detection or not. Our theoretical simulations find empirical validation in a compact horizontal atom gravity gradiometer. The adjustment of the differential phase significantly enhances measurement sensitivity, culminating in a differential gravity resolution of 1.6 × 10−10 g @ 4800 s.
Abstract Atom interferometers are reaching sensitivities fundamentally constrained by quantum fluctuations. A main challenge is to integrate entanglement into quantum sensing protocols to enhance precision while ensuring robustness against noise and systematics. Here, we theoretically investigate differential phase measurements with two atom interferometers using spin-squeezed states of N atoms, accounting for common-mode phase noise spanning the full 2 π range. We estimate the differential signal using model-free ellipse fitting, a robust method requiring no device calibration and resilient to additional noise sources. Our results show that spin-squeezing enables sensitivities below the standard quantum limit (SQL). Specifically, we identify optimal squeezed states that minimize the differential phase uncertainty, scaling as N − 2 / 3 , thus overcoming the SQL by a factor N 1 / 6 , while eliminating the bias inherent in ellipse fitting methods. We benchmark our protocol against the Cramér–Rao bound and compare it with hybrid methods that incorporate auxiliary classical sensors. Our findings provide a pathway to robust and high-precision atom interferometry, in realistic noisy environments and using readily available states and estimation methods.
We perform the experimental demonstration of the method proposed earlier [F. P. Dos Santos, Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.