In this paper, we propose an approach for implementing quantum-enhanced stimulated Raman scattering (QESRS) microscopy using a dual-polarization scheme. This approach has advantages for high-power operation and enables ultrasensitive Raman detection of molecular vibrational mode symmetry. To demonstrate the feasibility and effectiveness of our technique, we present both the theoretical framework and experimental results of dual-polarization QESRS. Our technique resulted in a noticeable reduction of noise on both parallel and orthogonal QESRS spectra as well as on the depolarization ratio spectra. These results validate the potential of our approach for achieving high-speed QESRS imaging with sub-shot-noise sensitivity.
In this paper, we propose an approach for implementing quantum-enhanced stimulated Raman scattering (QESRS) microscopy using a dual-polarization scheme. This approach has advantages for high-power operation and enables ultrasensitive Raman detection of molecular vibrational mode symmetry. To demonstrate the feasibility and effectiveness of our technique, we present both the theoretical framework and experimental results of dual-polarization QESRS. Our technique resulted in a noticeable reduction of noise on both parallel and orthogonal QESRS spectra as well as on the depolarization ratio spectra. These results validate the potential of our approach for achieving high-speed QESRS imaging with sub-shot-noise sensitivity.
Quantum-enhanced stimulated Raman scattering (QESRS) microscopy is expected to realize molecular vibrational imaging with sub-shot-noise sensitivity, so that weak signals buried in the laser shot noise can be uncovered. Nevertheless, the sensitivity of previous QESRS did not exceed that of state-of-the-art stimulated Raman scattering (SOA-SRS) microscopes mainly because of the low optical power (3 mW) of amplitude squeezed light [Nature594, 201 (2021)10.1038/s41586-021-03528-w]. Here, we present QESRS based on quantum-enhanced balanced detection (QE-BD). This method allows us to operate QESRS in a high-power regime (>30 mW) that is comparable to SOA-SRS microscopes, at the expense of 3 dB sensitivity drawback due to balanced detection. We demonstrate QESRS imaging with 2.89 dB noise reduction compared with classical balanced detection scheme. The present demonstration confirms that QESRS with QE-BD can work in the high-power regime, and paves the way for breaking the sensitivity of SOA-SRS microscopes.
Benefitting from the sub-Poissonian statistics, squeezed light has been applied to push the shot-noise-limited sensitivity of stimulated Raman scattering spectroscopy and microscopy to a sub-shot-noise level [5]. However, the balanced detection regime requires a high squeezing level to counteract the 3-dB signal-to-noise ratio (SNR) drawback. In this presentation, we introduce dual-polarization quantum-enhanced stimulated Raman scattering (QESRS), which is also suitable for high-power operation [6]. This approach utilizes a symmetric beamsplitter but detects squeezed light on two independent photodetectors, thus avoiding the 3-dB decrease in SNR.
Squeezed light has been applied in stimulated Raman scattering (SRS) spectroscopy [1] and microscopy [2] to break the shot-noise-limited sensitivity. The sub-shot-noise sensitivity achieved in quantum-enhanced SRS (QE-SRS) systems is advantageous for uncovering weak signals and achieving faster imaging speed, which attract the attention of biomedical scientists. To break the sensitivity of state-of-the-art SRS microscopes, the applied squeezed light power in QE-SRS systems should be high enough (>10mW). Recently, high-power picosecond-pulsed QE-SRS spectroscopy [3] based on balanced detection scheme [4] was reported, and a sensitivity that is comparable to state-of-the-art SRS microscopes was firstly demonstrated in QE-SRS microscopy based on the same scheme [5]. An important issue of QE-SRS based on balanced detection is the 3-dB additional noise, so >3-dB squeezing level is required to demonstrate an absolute sensitivity improvement compared with state-of-the-art SRS microscopes in single-photodiode detection scheme. However, it's hard to generate highly squeezed pulsed light because of the difficulty in temporal and spatial mode matching between squeezed vacuum (SQV) and local oscillator (LO). Here, we introduce QE-SRS in dual-polarization scheme, which can be implemented in high-power regime but is free from the 3-dB signal-to-noise ratio drawback.
Stimulated Raman scattering (SRS) microscopy is a powerful technique that allows for the visualization of molecular vibrational images for label-free imaging, metabolic imaging, and supermultiplex imaging. However, its sensitivity is mainly limited by the shot noise of laser pulses, and long acquisition times are sometimes required to detect weak SRS signals hidden by the shot noise. To overcome this limitation, quantum-enhanced (QE-) SRS microscopy has been demonstrated, while the low optical power of squeezed pulses limits the sensitivity. In this work, we present QE-SRS microscopy using quantum-enhanced balanced detection (QE-BD) scheme, where the sensitivity of balanced detection SRS microscope is enhanced by injecting squeezed vacuum, allowing for QE-SRS imaging with high power SRS pump pulses (typically several tens of milliwatt), while balanced detection causes 3 dB drawback in the signal-to-noise ratio. We experimentally demonstrate QE-SRS imaging with 2.6 dB noise reduction compared with shot-noise-limited balanced detection SRS. We also demonstrate hyperspectral QE-SRS imaging by fast wavelength tuning of Stokes pulses. These results show the potential feasibility of high-power QE-SRS whose sensitivity is beyond that of classical shot-noise-limited SRS microscopes.
Stimulated Raman scattering (SRS) microscopy is a powerful label-free imaging technique that probes the vibrational response of chemicals with high specificity and sensitivity. High-power, quantum-enhanced SRS microscopes have been recently demonstrated and applied to polymers and biological samples. Quantum correlations, in the form of squeezed light, enable the microscopes to operate below the shot noise limit, enhancing their performance without increasing the illumination intensity. This addresses the signal-to-noise ratio (SNR) and speed constraints introduced by photodamage in shot noise-limited microscopes. Previous microscopes have either used single-beam squeezing, but with insufficient brightness to reach the optimal ratio of pump-to-Stokes intensity for maximum SNR, or have used twin-beam squeezing and suffered a 3 dB noise penalty. Here we report a quantum-enhanced Raman microscope that uses a bright squeezed single-beam, enabling operation at the optimal efficiency of the SRS process. The increase in brightness leads to multimode effects that degrade the squeezing level, which we partially overcome using spatial filtering. We apply our quantum-enhanced SRS microscope to biological samples and demonstrate quantum-enhanced multispectral imaging of living cells. The imaging speed of 100×100 pixels in 18 seconds allows the dynamics of cell organelles to be resolved. The SNR achieved is compatible with video-rate imaging, with the quantum correlations yielding a 20% improvement in imaging speed compared to shot noise-limited operation.
Stimulated Raman scattering (SRS) microscopy has emerged as a powerful technique for probing the spatiotemporal dynamics of molecular bonds with exceptional sensitivity, resolution, and speed. However, classically, its performance remains fundamentally constrained by optical shot noise, which imposes a strict limit on detection sensitivity and speed. Here, we demonstrate a quantum-enhanced SRS microscopy platform that circumvents this barrier by harnessing amplitude-squeezed light. Specifically, we generate a Stokes beam with 5.2dB of amplitude squeezing using traveling-wave optical parametric amplification in second-order nonlinear waveguides, and combine it with a tunable coherent pump to access vibrational modes spanning from 1000 to 3100cm−1. Applied to quantum imaging of metabolites in biological tissue (pork muscle), our quantum-enhanced Raman microscope achieves an average noise suppression of 3.6dB and a 51% enhancement in signal-to-noise ratio (SNR) -- to the best of our knowledge, the largest improvement reported to date in quantum-enhanced SRS microscopy of biological samples.