The ability to measure the magnetic fields around celestial bodies enables various insights into processes and phenomena deep within such bodies.The use of magnetometry in space missions dates back to the 1950s, and a number of different technologies have been used to measure these fields, ranging from fluxgates to Anisotropic Magneto Resistance (AMR) sensors.Optically-pumped magnetometers (OPMs) represent the state-of-the-art in magnetic field sensitivity. 1 Such sensors rely upon the interaction of laser light to spin polarise a warm vapour of neutral atoms.Detecting the precession of these spins, again with laser light, is a direct way to measure a magnetic field and is relatable to fundamental constants.Improvements in quantum technology within the last decade have led to the miniaturisation of these sensors.We have now reached the point where compact, lightweight, and low power devices offer greater sensitivity to magnetic fields than any other technology.In this work, we identify the following four key space application areas in which OPMs may offer significant advantages over existing technologies: Environments in which high sensitivity is needed at low magnetic fields (10s of nT), full vector read-out with high directional sensitivity and reduced SWaP compared to helium magnetometers, miniaturised and lightweight scalar magnetometers to complement vector fluxgate measurements, vector or scalar sensors that need high (40 dB) gradiometer performance.This work identifies OPM configurations for each area and makes a first estimate of size, weight and power requirements for each.By enabling improvements in magnetic field sensitivity, this represents an exciting prospect for precision magnetic field measurements while also saving mass and reducing complexity.
The ability to measure the magnetic fields around celestial bodies enables various insights into processes and phenomena deep within such bodies.The use of magnetometry in space missions dates back to the 1950s, and a number of different technologies have been used to measure these fields, ranging from fluxgates to Anisotropic Magneto Resistance (AMR) sensors.Optically-pumped magnetometers (OPMs) represent the state-of-the-art in magnetic field sensitivity. 1 Such sensors rely upon the interaction of laser light to spin polarise a warm vapour of neutral atoms.Detecting the precession of these spins, again with laser light, is a direct way to measure a magnetic field and is relatable to fundamental constants.Improvements in quantum technology within the last decade have led to the miniaturisation of these sensors.We have now reached the point where compact, lightweight, and low power devices offer greater sensitivity to magnetic fields than any other technology.In this work, we identify the following four key space application areas in which OPMs may offer significant advantages over existing technologies: Environments in which high sensitivity is needed at low magnetic fields (10s of nT), full vector read-out with high directional sensitivity and reduced SWaP compared to helium magnetometers, miniaturised and lightweight scalar magnetometers to complement vector fluxgate measurements, vector or scalar sensors that need high (40 dB) gradiometer performance.This work identifies OPM configurations for each area and makes a first estimate of size, weight and power requirements for each.By enabling improvements in magnetic field sensitivity, this represents an exciting prospect for precision magnetic field measurements while also saving mass and reducing complexity.
Significance Optically pumped magnetometers (OPMs) are crucial in magnetic-field measurements. Its high sensitivity and low noise allow it to detect weak magnetic-field changes up to the nT level, thus significantly expanding human understanding into the micro-magnetic-field environment. OPMs are beneficial in various areas, including the precise mapping of Earth’s magnetic field, the detection of weak biological magnetic signals within biological tissues, quantum computing, and magnetic-material research.The main function of an OPM is to detect magnetic fields using specific polarized pump light and detection light. High-purity pump light, which is typically linearly or circularly polarized, interacts with atomic cells. The selective excitation of pump light causes the arrangement of atomic magnetic moments to align with the polarization direction of light, thus forming a magnetized region. This process is known as optical pumping, which effectively places atoms in specific magnetic quantum states, thereby enhancing their sensitivity to magnetic fields. This allows the detection of light passing through magnetized regions with different polarization states. Under the effect of a magnetic field, the energy levels of atoms undergo Zeeman splitting, which affects the absorption and scattering of detection light. By analyzing and detecting changes in light intensity or polarization rotation, the intensity and direction of the magnetic field can be inferred accurately. The polarization state must be controlled precisely as it determines the manner by which atoms are excited and their response to magnetic fields, thereby ensuring the high sensitivity and measurement accuracy of the equipment. This principle based on atomic magnetic resonance renders the OPM an ideal tool for detecting weak magnetic fields; thus, OPMs are widely used in scientific research and practical applications.Aided by the development of modern technology, researchers have comprehensively investigated vector lights with complex polarization states and gradually applied them to OPMs. In an OPM, particularly the component involving the interaction between vector light and atoms, dichroism and birefringence are two key optical phenomena. Dichroism refers to the different propagation characteristics of light in different polarization directions. This characteristic is used to selectively excite or manipulate atoms of specific energy levels in an OPM. Birefringence refers to the difference in the refractive index between vertically and horizontally polarized light in a medium, which causes a beam to separate when it passes through an atomic medium. By leveraging the properties above and examining the practical application of vector light in OPMs, we can further improve the sensitivity of OPMs. Compared with conventional OPMs, a new type of OPM based on vector light pumping/detection features rapid response, adaptability to more complex environments, and high sensitivity. Owing to the vector characteristics of vector light, this OPM can simultaneously measure multiple components of the magnetic field, thus achieving complete magnetic-field vector measurements without requiring additional optical paths. Therefore, it is more suitable for integration into complex optical systems in fields such as biomedical, material science, and space exploration. Progress This paper summarizes the development history of OPMs, describes their operating principle (Figs. 2 and 3), and explains the energy-level transition of optically pumped polarized alkali metal atoms based on a 87Rb atomic energy-level diagram (Fig. 4). As per the development history of OPMs, optical polarization is crucial to the entire process (Fig. 5). Vector light is a new type of beam that has emerged in recent years, and its polarization state is distributed in a certain pattern on the cross-section of the beam (Fig. 6). The measurement of vector light in a magnetic field has been investigated extensively (Fig. 7). In terms of light and matter, investigating the dichroism and birefringence in the interaction between vector light and alkali metal atoms is crucial for OPMs. Based on dichroism, when a beam of linearly polarized light is irradiated onto an alkali metal atomic-gas chamber, the absorption and scattering efficiency of light varies owing to the ultrafine structure of the atoms and the energy levels of different magnetic quantum numbers. By adjusting the polarization direction of light, atoms can be more effectively pumped into specific magnetic states, thereby enhancing their response to magnetic fields (Fig. 8). Based on birefringence, vector light is incident in the orthogonal pumping direction, and the relationship between the polarization rotation angle of the detected light and the external magnetic field after the light passes through the gas chamber can be derived (Fig. 9). In practical applications, vector light with complex polarization states can be used as pump/detection light not only for the real-time dynamic detection of the magnetic-field size (Fig. 10) but also for solving the “dead zone” problem in magnetometers, improving spatial resolution and sensitivity (Fig. 11), and achieving miniaturized OPMs. Conclusions and Prospects Comprehensive investigations into quantum optics and the development of micro- and nano-technology will refine the manipulation of vector light, which is expected to enable magnetic-field measurements with higher sensitivities and resolutions. New OPMs based on vector optical pumping/detection have gradually received the attention of researchers. Thus, the application of OPMs in biomedicine, geological exploration, quantum information processing, and other fields will be promoted. Additionally, the miniaturization and integrated design of OPMs render them more portable and will further broaden their practical use. In the future, the development of vector-light technology will significantly improve OPMs.
The optically pumped magnetometer (OPM) is a class of atomic devices that rely on the measurement of Larmor precession of an atomic spin ensemble in a magnetic field. They need the specific frequency light to complete the pumping and detection process. OPMs typically work under the Earth's magnetic field or a limited field. When operating in near-zero field, they can realize the spin-exchange relaxation-free (SERF) regime, thereby promoting a substantial increase in sensitivity. At present, OPMs have been widely used in magnetoencephalography, magnetocardiography, geomagnetic detection, and inertia measurement (comagnetometer). There are a large number of researchers engaged in the study of relevant mechanisms, devices, technologies, and applications. More importantly, supported by MEMS technology and micro/nano optics, OPMs have the potential to move toward chip-scale sensors. This special issue contains some latest developments in OPMs and related areas. We hope the reprint can provide valuable references for researchers in the related field.
Airborne magnetometry requires rigorous calibration to isolate geomagnetic signals from sensor errors and platform magnetic fields. This magnetic compensation is needed for applications like geophysical exploration and magnetic anomaly navigation. The standard approach utilizes a quantum scalar Optically Pumped Magnetometer (OPM) and a less sensitive fluxgate vector sensor for attitude information. This configuration typically results in a scalar approximation of the platform field.
Advancements in high-sensitivity Diamond Nitrogen-Vacancy (NV) vector magnetometers now enable a re-evaluation of the standard hardware configuration and full vector calibration models. We show through rigorous theoretical analysis that scalar calibration models are robust to misalignment. Vector calibration models, however, are intrinsically first-order sensitive to attitude errors, irrespective of the accuracy of the magnetic field measurements. These errors arise from inaccurate representation of the background field direction in the body frame, and can amplify small orientation errors into noticeable calibration residuals.
Using realistic sensor models and flight trajectories, we evaluate different sensor configurations for magnetic calibration and assess the use of onboard Inertial Navigation Systems (INS) as an independent attitude reference to enable stable compensation. Our results suggest that quantum vector magnetometers like NV sensors are not sufficient to solve the attitude bottleneck for airborne vector magnetic calibration. However, as a single sensor capable of providing both absolute field and directional measurements, they may offer benefits regarding sensor placement, synchronization, and scalar calibration accuracy.
As one of the fundamental properties of matter, magnetic fields have extensive application value in fields such as military, medical, and industrial sectors. High-sensitivity magnetic field measurement technology is crucial for exploring the physical world, ensuring national security, and promoting industrial development. Traditional magnetic sensors based on classical physics principles, such as fluxgate and Hall effect sensors, have become increasingly difficult to meet growing demands in terms of sensitivity, volume, and power consumption. In contrast, atomic magnetometers based on quantum effects utilize the interaction between atomic spins and external magnetic fields for measurement, offering advantages such as high sensitivity, no requirement for cryogenic cooling, and the capability for absolute measurement, making them a novel type of magnetic sensor that has received significant attention in recent years. In particular, the development of chip-scale atomic magnetometers, through technologies such as Micro-Electro-Mechanical Systems (MEMS), has significantly reduced the volume and power consumption of atomic magnetometers, enabling them to demonstrate tremendous application potential in fields such as ocean exploration, biomedical applications, and geological exploration. This paper will review the technological advances of high-sensitivity chip-scale atomic magnetometers, with a focus on discussing the latest achievements in their miniaturization and small-scale research.
The development of optically pumped magnetometers (OPMs) capable of operating in fields up to and beyond Earth's field has been accelerated in recent years by advances in the micro-fabrication of components, such as alkali-vapour cells and chip-scale lasers, and the application of spin-exchange relaxation suppression techniques, such as light-narrowing. Using these techniques, OPMs can be built for highly-accurate scalar geo-magnetometry. Sub-picotesla sensitivity can be achieved in compact packages, and commercialisation of these technologies is progressing globally. We review the underlying principles for OPM operation, including optimisation of microfabricated alkali vapour cells, and summarise the current state-of-the-art in their application.
Advances in Optical and Photonic Devices 330 integration into microfabricated packages.Such packages will be not only inexpensive and easy to batch produce they will also have lower power consumption, light weight and unimpeded mobility (Knappe et al., 2006).Sensitive magnetic field measurements, for which AMs can be used, are important owing to many existing and potential applications.Magnetometers have been in wide use, for example, in geology, military, biomagnetism, space magnetic field measurements.AMs have been used because they are both relatively sensitive compared to conventional inexpensive magnetometers, such as fluxgates, and more convenient compared to SQUIDs that require cryogenic cooling.For a long time low-T c SQUIDs had been by far the most sensitive magnetometers at low frequency.However, this has changed with the demonstration with AMs of record 0.5 fT/Hz 1/2 sensitivity (Kominis et al., 2003).High-sensitivity AMs are based on spin-polarized atomic gases or vapors, and AM research is closely related to the atomic physics subfield dedicated to the investigation of spin interactions in such media.This subfield includes the research on optical pumping and related topics such as atomic clocks, masers, hyperpolarized gases, spin-based spectroscopy, and some others.A comprehensive review of optical pumping experiments before 1972 and theory of optical pumping and various relaxation mechanisms are given by William Happer (Happer, 1972).This theory, which still stands the test of time, includes the formulation of density matrix equations, which can be directly applied to the analysis of magnetic resonances of vapors on which atomic magnetometers are based.Atomic magnetometers find many applications as other magnetometers, but they are most useful when high sensitivity and non-cryogenic operation are required.For example, AMs have been developed for submarine detection, and many other military applications are possible on similar principles.Some applications of Rb-vapor or 3 He magnetometers in geophysics and space physics were mentioned as early as in 1961 by Bloom (Bloom, 1961) who did some pioneering work on the high-sensitivity measurements of magnetic fields and theory for the operation of atomic magnetometers.Theoretical analysis of early atomic magnetometers was also done by Dehmelt (Dehmelt, 1957) and by Bell and Bloom (Bell & Bloom, 1957).Although the history of atomic magnetometers is quite fascinating and they played an important role in applications where simpler and less expensive methods did not provide sufficient sensitivity, the atomic magnetometers of the past were much less sensitive than the modern ones.Most exciting results appeared only recently with the various demonstrations of performance of high-density AMs, which we would like to focus on in this chapter. How to referenceIn order to correctly reference this scholarly work, feel free to copy and paste the following: Igor Savukov (2010).Ultra-Sensitive Optical Atomic Magnetometers and Their Applications, Advances in Optical and Photonic Devices, Ki Young Kim (Ed.),