Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Scientific Reports

Micro mercury trapped ion clock prototypes with 10$$^{-14}$$ frequency stability in 1-liter packages

Thai M. Hoang, Sang Kun Chung, Thanh Le, Sehyun Park, Sung‐Jin Park, James Gary Eden, Christopher E. Holland, Hao Wang, Omeed Momeni, Russell Bradley, S. G. Crane, John D. Prestage, Nan Yu

Published Jun 30, 2023• 13 citations
Publisher

Abstract

Modern communication and navigation systems are increasingly relying on atomic clocks. As timing precision requirements increase, demands for lower SWaP (size, weight, and power) clocks rise. However, it has been challenging to break through the general trade-off trend between the clock stability performance and SWaP. Here we demonstrate micro mercury trapped ion clock (M2TIC) prototypes integrated with novel micro-fabricated technologies to simultaneously achieve high performance and low SWaP. The M2TIC prototypes could reach the [Formula: see text]-stability level in 1 day with a SWaP of 1.1 L, 1.2 kg, and under 6 W of power. This stability level is comparable to the widely used rack-mount Microchip 5071A cesium frequency standard. These standalone prototypes survived regular commercial shipping across the North American continent to a government laboratory, where their performance was independently tested. The M2TIC sets a new reference point for SWaP and performance and opens opportunities for high-performance clocks in terrestrial and space applications.

DOI
10.1038/s41598-023-36411-x

Related papers

Demonstration of a Mercury Trapped Ion Clock Prototype

Thai M. Hoang, Sang Kun Chung, Thanh Le +8 more

In this work, we report a prototype of micro mercury trapped ion atomic clock. All the clock components have been packaged and demonstrated in a magnetic shield box of 4 liters. The prototype clock shows promising performance with a short-term fractional frequency instability below 10−11τ−12and can reach the 10−14-instability level after a day of averaging. The prototype clock is capable of reaching the10−15-fractional frequency instability range. Our demonstration of the integrated clock prototype paves the way for further SWaP reduction and maturation.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 7, 2021•3 citations

Performance of Micro Mercury Trapped Ion Clock

Thai M. Hoang, Sang Kun Chung, Thanh Le +4 more

Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•10 citations

Realization of a compact mercury ion microwave clock with frequency stability of 6.3 × 10− 16

Hao Liu, Yi-He Chen, Jian Wang +6 more

Abstract The mercury ion microwave clock is considered to be one of the leading candidates for new generation satellite navigation atomic clocks due to its excellent long-term frequency stability, extremely low frequency drift rate, high reliability and good potential for miniaturization. In recent years, the performance and maturity of the space mercury ion microwave clock have improved rapidly, and the reported long-term stability results are mostly in low 10 − 15 level. In this article, we present a compact prototype of mercury ion microwave clock aiming to spaceborne applications with the long-term stability of 10 − 16 . By regulating the physical effects contributing to the clock transition frequency shifts, the clock maintains a white frequency noise Allan deviation of 2.8×10 − 13 / τ 1/2 even with the averaging time τ over 10 5 s and achieves the long-term stability of 6.3 × 10 − 16 for averaging times of 200000 s. The space mercury ion microwave clock with such level performance will benefit the Global Navigation Satellite Systems and a wide range of space science and missions.

Scientific Reports•Dec 15, 2025•2 citations

Single-ion traps and cubic cavities for field-deployable laser-cooled optical atomic clocks

Alessio Spampinato, Jonathan Stacey, M. A. Trigatzis +5 more

Abstract The primary technology for high accuracy position, navigation and timing (PNT) capability worldwide is currently provided by global navigation satellite systems (GNSS). The vulnerability of GNSS to intentional interference, clock component failure or extreme space weather is increasingly pointing to the need for alternative independent navigation and timing solutions to maintain critical national infrastructures, defence, security, commerce and logistics. The availability of low size, weight and power (SWaP) portable atomic clock technology with resilience and extended holdover times for use both in space and terrestrially is now increasingly urgent. In this paper, we report on progress in the development of compact optical clocks that offer the capability to out-perform existing commercial microwave atomic clock systems. We discuss designs for a compact transportable cold trapped strontium ion optical clock with both a low SWaP design and high accuracy that can address extended holdover for future navigation and timing requirements. We describe how key sub-systems of an optical atomic clock, namely the single ion trap physics package and multi-wavelength dual-axis cubic cavity clock control unit have been redesigned to reduce SWaP. The optical cavity is needed to frequency stabilise the lasers for laser cooling and state preparation as well as the clock laser for interrogating the ion’s clock transition. We describe the results of finite element analysis (FEA) to model the electrical and thermal behaviour of a compact ion trap design. We also consider the design space for small cubic optical cavities, investigating the possible limits for achieving a minimal SWaP for the system.

•Jun 12, 2026•0 citations

Integrated physics package of micromercury trapped ion clock with 10−14-level frequency stability

Thai M. Hoang, Sang Kun Chung, Thanh Le +8 more

Mercury trapped ion clocks have demonstrated great long-term frequency stability and robustness. In this paper, we report a demonstration of an integrated 100-cc physics package in an effort to develop a micromercury trapped ion clock with high frequency stability. The physics package consists of a sealed 30-cc vacuum tube with one layer of magnetic shielding, light source, and detector assembly. A field emitter array and a 194-nm microplasma lamp were employed together with a microtrap tube to reduce the size and power consumption for a mercury trapped ion clock. We show that the 100-cc physics package is capable of providing a fractional frequency stability of 1×10−11τ−1/2 down to 5×10−14 after a few hours of integration. We also show a set of environmental sensitivity evaluations as well as the clock frequency retrace.

Applied Physics Letters•Jul 26, 2021•15 citations

Miniature microwave frequency standard with trapped 171Yb+

Yuan‐Yu Jau, Peter D. D. Schwindt, Adrian L. Casias +12 more

We report the development of a low-power, miniature Yb-171 ion clock at Sandia National Laboratories. This work is funded by the DARPA micro Position, Navigation, and Timing program under the Integrated Micro Primary Atomic Clock Technology (IMPACT) project. The ultimate goal is to develop a frequency standard that has frequency stability comparable to a commercial Cs beam standard, but with 100 to 1000 times smaller size and power consumption. The Yb-171 ion has a microwave clock traItem MIN :YXB4-01335-A112nsition at 12.6 GHz, and the natural linewidth of the clock resonance is expected to be less than 10-3Hz, which leads to a very high-Q clock resonance. An atomic clock using trapped ions is an excellent candidate for miniaturization because ions are well isolated from the environment independently of the size of the trap. Compared to optical traps for neutral atoms, the trapping depth of RF traps for ions is usually several orders of magnitude deeper. Therefore, the requirement for the vacuum level is more forgiving. We have successfully developed miniature ion-trap vacuum packages as shown in Fig. 1. Usually, a few microTorr of He buffer gas is introduced into each of our miniature ion-trap vacuum packages, which are sealed and passively pumped by non-evaporable getters. Using a sealed 3 cc ion-trap package, we were able to demonstrate long-term clock operation, with the stability reaching the 10-14range after a few days of integration [1].

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•0 citations
Micro mercury trapped ion clock prototypes with 10−14^{-14}−14 frequency stability in 1-liter packages
Modern communication and navigation systems are increasingly relying on atomic clocks. As timing precision requirements increase, demands for lower SWaP (size, weight, and power) clocks rise. However, it has been challenging to break through the general trade-off trend between the clock stability performance and SWaP. Here we demonstrate micro mercury trapped ion clock (M2TIC) prototypes integrated with novel micro-fabricated technologies to simultaneously achieve high performance and low SWaP. The M2TIC prototypes could reach the [Formula: see text]-stability level in 1 day with a SWaP of 1.1 L, 1.2 kg, and under 6 W of power. This stability level is comparable to the widely used rack-mount Microchip 5071A cesium frequency standard. These standalone prototypes survived regular commercial shipping across the North American continent to a government laboratory, where their performance was independently tested. The M2TIC sets a new reference point for SWaP and performance and opens opportunities for high-performance clocks in terrestrial and space applications.
In this work, we report a prototype of micro mercury trapped ion atomic clock. All the clock components have been packaged and demonstrated in a magnetic shield box of 4 liters. The prototype clock shows promising performance with a short-term fractional frequency instability below 10−11τ−12and can reach the 10−14-instability level after a day of averaging. The prototype clock is capable of reaching the10−15-fractional frequency instability range. Our demonstration of the integrated clock prototype paves the way for further SWaP reduction and maturation.
Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.
Abstract The mercury ion microwave clock is considered to be one of the leading candidates for new generation satellite navigation atomic clocks due to its excellent long-term frequency stability, extremely low frequency drift rate, high reliability and good potential for miniaturization. In recent years, the performance and maturity of the space mercury ion microwave clock have improved rapidly, and the reported long-term stability results are mostly in low 10 − 15 level. In this article, we present a compact prototype of mercury ion microwave clock aiming to spaceborne applications with the long-term stability of 10 − 16 . By regulating the physical effects contributing to the clock transition frequency shifts, the clock maintains a white frequency noise Allan deviation of 2.8×10 − 13 / τ 1/2 even with the averaging time τ over 10 5 s and achieves the long-term stability of 6.3 × 10 − 16 for averaging times of 200000 s. The space mercury ion microwave clock with such level performance will benefit the Global Navigation Satellite Systems and a wide range of space science and missions.
Abstract The primary technology for high accuracy position, navigation and timing (PNT) capability worldwide is currently provided by global navigation satellite systems (GNSS). The vulnerability of GNSS to intentional interference, clock component failure or extreme space weather is increasingly pointing to the need for alternative independent navigation and timing solutions to maintain critical national infrastructures, defence, security, commerce and logistics. The availability of low size, weight and power (SWaP) portable atomic clock technology with resilience and extended holdover times for use both in space and terrestrially is now increasingly urgent. In this paper, we report on progress in the development of compact optical clocks that offer the capability to out-perform existing commercial microwave atomic clock systems. We discuss designs for a compact transportable cold trapped strontium ion optical clock with both a low SWaP design and high accuracy that can address extended holdover for future navigation and timing requirements. We describe how key sub-systems of an optical atomic clock, namely the single ion trap physics package and multi-wavelength dual-axis cubic cavity clock control unit have been redesigned to reduce SWaP. The optical cavity is needed to frequency stabilise the lasers for laser cooling and state preparation as well as the clock laser for interrogating the ion’s clock transition. We describe the results of finite element analysis (FEA) to model the electrical and thermal behaviour of a compact ion trap design. We also consider the design space for small cubic optical cavities, investigating the possible limits for achieving a minimal SWaP for the system.
Mercury trapped ion clocks have demonstrated great long-term frequency stability and robustness. In this paper, we report a demonstration of an integrated 100-cc physics package in an effort to develop a micromercury trapped ion clock with high frequency stability. The physics package consists of a sealed 30-cc vacuum tube with one layer of magnetic shielding, light source, and detector assembly. A field emitter array and a 194-nm microplasma lamp were employed together with a microtrap tube to reduce the size and power consumption for a mercury trapped ion clock. We show that the 100-cc physics package is capable of providing a fractional frequency stability of 1×10−11τ−1/2 down to 5×10−14 after a few hours of integration. We also show a set of environmental sensitivity evaluations as well as the clock frequency retrace.
We report the development of a low-power, miniature Yb-171 ion clock at Sandia National Laboratories. This work is funded by the DARPA micro Position, Navigation, and Timing program under the Integrated Micro Primary Atomic Clock Technology (IMPACT) project. The ultimate goal is to develop a frequency standard that has frequency stability comparable to a commercial Cs beam standard, but with 100 to 1000 times smaller size and power consumption. The Yb-171 ion has a microwave clock traItem MIN :YXB4-01335-A112nsition at 12.6 GHz, and the natural linewidth of the clock resonance is expected to be less than 10-3Hz, which leads to a very high-Q clock resonance. An atomic clock using trapped ions is an excellent candidate for miniaturization because ions are well isolated from the environment independently of the size of the trap. Compared to optical traps for neutral atoms, the trapping depth of RF traps for ions is usually several orders of magnitude deeper. Therefore, the requirement for the vacuum level is more forgiving. We have successfully developed miniature ion-trap vacuum packages as shown in Fig. 1. Usually, a few microTorr of He buffer gas is introduced into each of our miniature ion-trap vacuum packages, which are sealed and passively pumped by non-evaporable getters. Using a sealed 3 cc ion-trap package, we were able to demonstrate long-term clock operation, with the stability reaching the 10-14range after a few days of integration [1].