Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

Single shot imaging for cold atoms based on machine learning

Da-Wei Ying, Sihui Zhang, Shujin Deng, Haibin Wu

Published Jan 1, 2023• 2 citations
Publisher

Abstract

The ability to detect atoms in high spatiotemporal resolution provides a powerful tool for us to investigate the quantum properties of ultracold quantum gases. Plenty of useful imaging methods, including absorption imaging, phase contrast imaging and fluorescence imaging, have been implemented in detecting atoms. Among them, absorption imaging is the most widely used method in cold atoms laboratory. However, the traditional absorption imaging method is affected by perturbations such as interference between optical elements, fluctuation of laser power, frequency, and spatial position, resulting in residual spatially structured noise and degradation of imaging quality. Especially for regions with lower density or for longer time-of-flight, a large number of repetitions are often required to obtain better signal-to-noise ratio, which would increase the time cost and induce other noise. One must reduce the time between two imaging pulses to suppress the spatial noise. A better charge coupled device (CCD) with higher frame transfer rate or other method like fast-kinetic mode will be used to improve the imaging quality. In this paper, a single-shot cold atom imaging method based on machine learning is proposed, in which only one absorption imaging of cold atoms is required, and the corresponding background image can be generated through the neural network of an autoencoder. This effectively reduces the spatial striped noise in imaging, significantly improves the imaging quality, and makes it possible for cold atoms to be imaged multiple times in a single cycle.

DOI
10.7498/aps.72.20230449

Related papers

Single-Exposure Absorption Imaging of Ultracold Atoms Using Deep Learning

Gal Ness, Anastasiya Vainbaum, Constantine Shkedrov +2 more

Absorption imaging is the most common probing technique in experiments with ultracold atoms. The standard procedure involves the division of two frames acquired at successive exposures, one with the atomic absorption signal and one without. A well-known problem is the presence of residual structured noise in the final image, due to small differences between the imaging light in the two exposures. Here, we solve this problem by performing absorption imaging with only a single exposure, where instead of a second exposure the reference frame is generated by an image-completion autoencoder neural network. The network is trained on images without an absorption signal, such that it can infer the noise overlaying the atomic signal based only on the information in the region encircling the signal. We demonstrate our approach on data captured with a quantum degenerate Fermi gas. The average residual noise in the resulting images is below that of the standard double-shot technique. Our method simplifies the experimental sequence, reduces the hardware requirements, and can improve the accuracy of extracted physical observables. The trained network and its generating scripts are available as an open-source repository (absDL.github.io).

arXiv:2003.01643•Physical Review Applied•Jul 6, 2020•29 citations

Noise suppression and image enhancement in cold atom absorption imaging

Pengcheng Zheng, Songqian Zhang, Zhu Ma +7 more

The noise in absorption imaging of cold atoms significantly impacts measurement accuracy across a range of applications with ultracold atoms. It is crucial to adopt an approach that offers effective denoising capabilities without compromising the unique structure of atom clouds. Here, we introduce, to our knowledge, a novel image enhancement algorithm for cold atomic absorption imaging. The algorithm successfully suppresses background noise, enhancing image contrast significantly. Experimental results showcase that this approach can improve the image's signal-to-noise ratio by about 10 dB and enhance the uncertainty of cold atom number measurements by approximately tenfold, preserving the spatial distribution of the atom clouds. Moreover, the method exhibits exceptional performance and robustness when confronted with fringe noise and multi-component imaging scenarios, offering high stability. Importantly, this method can perform denoising based on a single image (without the need to establish a reference library), and the optimization process is entirely automated, eliminating the need for manual parameter selection. The method is both compatible and practical, making it applicable to various cold atom absorption imaging fields.

Applied Optics•Dec 2, 2024•2 citations

Optimized observable readout from single-shot images of ultracold atoms via machine learning

Axel U. J. Lode, Rui Lin, Miriam Büttner +6 more

Single-shot images are the standard readout of experiments with ultracold atoms, the imperfect reflection of their many-body physics. The efficient extraction of observables from single-shot images is thus crucial. Here we demonstrate how artificial neural networks can optimize this extraction. In contrast to standard averaging approaches, machine learning allows both one- and two-particle densities to be accurately obtained from a drastically reduced number of single-shot images. Quantum fluctuations and correlations are directly harnessed to obtain physical observables for bosons in a tilted double-well potential at an extreme accuracy. Strikingly, machine learning also enables a reliable extraction of momentum-space observables from real-space single-shot images and vice versa. With this technique, the reconfiguration of the experimental setup between in situ and time-of-flight imaging is required only once to obtain training data, thus potentially granting an outstanding reduction in resources.

arXiv:2010.14510•Physical Review A•Oct 8, 2021•17 citations

Ultracold atomic imaging based on enhanced fringe removal method

Shuai Wang, Xi Li, Xing-Can Yao

Absorption imaging is the foundation for quantitative measurements in experiments on ultracold atoms. This technique mainly involves capturing images of both the probing light field and the atom absorption light field. In this process, the unavoidable jitter of the probing light introduces imaging noise of fringe patterns into the atomic optical density distribution OD. In conventional fringe removal algorithms, this type of noise can be normalized by constructing an optimal reference image from multiple reference images that have been actually taken, which shares similar fringe patterns to an absorption image (Fig. (a)). Although this method works well in the region without atomic signal, they often overlook the modulation of the noise signal due to atomic absorption effects, leading to persistent residual fringes on the atom clouds. This problem becomes more pronounced with atomic density increasing. Here, we propose an enhanced fringe removal algorithm that takes into account the effects of atomic absorption, and actively modulates the intensity of the noise signal in the reference image constructed by conventional fringe removal algorithms (Fig. (b)), effectively preventing the residual fringes from forming, thus significantly improving the signal-to-noise ratio of the atomic images. When applied to the absorption imaging of homogeneous Fermi gases with high density, as shown in Fig. (d), this new algorithm successfully reduces the relative standard deviation of optical depth characterizing atomic density fluctuations by approximately 37%, which is about 3 times the relative standard deviation by conventional algorithm. Three subgraphs in Fig. (e) show the optical depth distribution at corresponding data points labeled by square boxes in Fig. (d). Furthermore, we also use this technique to quantitatively determine the second sound in the unitary Fermi superfluid of 6Li atoms. Compared with conventional fringe removal methods, our new algorithm increases the correlation function’s contrast of the density wave nearly 4 times, therefore enhancing the intensity of the density response spectrum by approximately 15% with half the measured standard error, paving the way for quantitatively determining the speed and attenuation of the second sound. These results demonstrate that the enhanced fringe removal algorithm not only effectively suppresses fringe noise, but also facilitates the identification and detection of important physical phenomena in high-density atomic systems, such as some collective excitations and new quantum phases.

Acta Physica Sinica•Jan 1, 2024•0 citations

Nanosecond super-resolved imaging of a single cold atom by stimulated emission depletion microscopy

Zhong-Hua Qian, Jin‐Ming Cui, Xi-Wang Luo +6 more

As one of the most critical methods for optical super-resolved microscopy, stimulated emission depletion (STED) microscopy has been widely applied in biological and chemical fields, leading to the Nobel prize of 2014 in chemistry. In cold atomic systems, fast and high-resolution microscopy of individual atoms is crucial since it can provide direct information on the dynamics and correlations of the system. Here, we demonstrate nanosecond two-dimensional snapshots of a single trapped ion beyond the optical diffraction limit, by combining the main idea of STED with the quantum state transition control in cold atoms. We achieve a spatial resolution up to 175 nm and a time resolution up to 50 ns simultaneously using a NA=0.1 objective in the experiment, which is improved over ten times compared to direct fluorescence imaging. To show the potential of this method, we applied it to record the motion of the trapped ion and observe one cycle of the secular motion of the ion with a displacement detection sensitivity of 10 nm. Our method provides a powerful tool for probing particles' positions, momenta and correlations, as well as their dynamics in cold atomic systems.

•Apr 20, 2021•1 citation

Comparison of two absorption imaging methods to detect cold atoms in magnetic trap

Yan Wang, Zhaohui Hu, Lu Qi

Two methods of absorption imaging to detect cold atoms in a magnetic trap are implemented for a high-precision cold atom interferometer. In the first method, a probe laser which is in resonance with a cycle transition frequency is used to evaluate the quantity and distribution of the atom sample. In the second method, the probe laser is tuned to an open transition frequency, which stimulates a few and constant number of photons per atom. This method has a shorter interaction time and results in absorption images which are not affected by the magnetic field and the light field. We make a comparison of performance between these two imaging methods in the sense of parameters such as pulse duration, light intensity, and magnetic field strength. The experimental results show that the second method is more reliable when detecting the quantity and density profiles of the atoms. These results fit well to the theoretical analysis.

Chinese Physics B•Feb 1, 2015•1 citation
The ability to detect atoms in high spatiotemporal resolution provides a powerful tool for us to investigate the quantum properties of ultracold quantum gases. Plenty of useful imaging methods, including absorption imaging, phase contrast imaging and fluorescence imaging, have been implemented in detecting atoms. Among them, absorption imaging is the most widely used method in cold atoms laboratory. However, the traditional absorption imaging method is affected by perturbations such as interference between optical elements, fluctuation of laser power, frequency, and spatial position, resulting in residual spatially structured noise and degradation of imaging quality. Especially for regions with lower density or for longer time-of-flight, a large number of repetitions are often required to obtain better signal-to-noise ratio, which would increase the time cost and induce other noise. One must reduce the time between two imaging pulses to suppress the spatial noise. A better charge coupled device (CCD) with higher frame transfer rate or other method like fast-kinetic mode will be used to improve the imaging quality. In this paper, a single-shot cold atom imaging method based on machine learning is proposed, in which only one absorption imaging of cold atoms is required, and the corresponding background image can be generated through the neural network of an autoencoder. This effectively reduces the spatial striped noise in imaging, significantly improves the imaging quality, and makes it possible for cold atoms to be imaged multiple times in a single cycle.
Absorption imaging is the most common probing technique in experiments with ultracold atoms. The standard procedure involves the division of two frames acquired at successive exposures, one with the atomic absorption signal and one without. A well-known problem is the presence of residual structured noise in the final image, due to small differences between the imaging light in the two exposures. Here, we solve this problem by performing absorption imaging with only a single exposure, where instead of a second exposure the reference frame is generated by an image-completion autoencoder neural network. The network is trained on images without an absorption signal, such that it can infer the noise overlaying the atomic signal based only on the information in the region encircling the signal. We demonstrate our approach on data captured with a quantum degenerate Fermi gas. The average residual noise in the resulting images is below that of the standard double-shot technique. Our method simplifies the experimental sequence, reduces the hardware requirements, and can improve the accuracy of extracted physical observables. The trained network and its generating scripts are available as an open-source repository (absDL.github.io).
The noise in absorption imaging of cold atoms significantly impacts measurement accuracy across a range of applications with ultracold atoms. It is crucial to adopt an approach that offers effective denoising capabilities without compromising the unique structure of atom clouds. Here, we introduce, to our knowledge, a novel image enhancement algorithm for cold atomic absorption imaging. The algorithm successfully suppresses background noise, enhancing image contrast significantly. Experimental results showcase that this approach can improve the image's signal-to-noise ratio by about 10 dB and enhance the uncertainty of cold atom number measurements by approximately tenfold, preserving the spatial distribution of the atom clouds. Moreover, the method exhibits exceptional performance and robustness when confronted with fringe noise and multi-component imaging scenarios, offering high stability. Importantly, this method can perform denoising based on a single image (without the need to establish a reference library), and the optimization process is entirely automated, eliminating the need for manual parameter selection. The method is both compatible and practical, making it applicable to various cold atom absorption imaging fields.
Single-shot images are the standard readout of experiments with ultracold atoms, the imperfect reflection of their many-body physics. The efficient extraction of observables from single-shot images is thus crucial. Here we demonstrate how artificial neural networks can optimize this extraction. In contrast to standard averaging approaches, machine learning allows both one- and two-particle densities to be accurately obtained from a drastically reduced number of single-shot images. Quantum fluctuations and correlations are directly harnessed to obtain physical observables for bosons in a tilted double-well potential at an extreme accuracy. Strikingly, machine learning also enables a reliable extraction of momentum-space observables from real-space single-shot images and vice versa. With this technique, the reconfiguration of the experimental setup between in situ and time-of-flight imaging is required only once to obtain training data, thus potentially granting an outstanding reduction in resources.
Absorption imaging is the foundation for quantitative measurements in experiments on ultracold atoms. This technique mainly involves capturing images of both the probing light field and the atom absorption light field. In this process, the unavoidable jitter of the probing light introduces imaging noise of fringe patterns into the atomic optical density distribution OD. In conventional fringe removal algorithms, this type of noise can be normalized by constructing an optimal reference image from multiple reference images that have been actually taken, which shares similar fringe patterns to an absorption image (Fig. (a)). Although this method works well in the region without atomic signal, they often overlook the modulation of the noise signal due to atomic absorption effects, leading to persistent residual fringes on the atom clouds. This problem becomes more pronounced with atomic density increasing. Here, we propose an enhanced fringe removal algorithm that takes into account the effects of atomic absorption, and actively modulates the intensity of the noise signal in the reference image constructed by conventional fringe removal algorithms (Fig. (b)), effectively preventing the residual fringes from forming, thus significantly improving the signal-to-noise ratio of the atomic images. When applied to the absorption imaging of homogeneous Fermi gases with high density, as shown in Fig. (d), this new algorithm successfully reduces the relative standard deviation of optical depth characterizing atomic density fluctuations by approximately 37%, which is about 3 times the relative standard deviation by conventional algorithm. Three subgraphs in Fig. (e) show the optical depth distribution at corresponding data points labeled by square boxes in Fig. (d). Furthermore, we also use this technique to quantitatively determine the second sound in the unitary Fermi superfluid of 6Li atoms. Compared with conventional fringe removal methods, our new algorithm increases the correlation function’s contrast of the density wave nearly 4 times, therefore enhancing the intensity of the density response spectrum by approximately 15% with half the measured standard error, paving the way for quantitatively determining the speed and attenuation of the second sound. These results demonstrate that the enhanced fringe removal algorithm not only effectively suppresses fringe noise, but also facilitates the identification and detection of important physical phenomena in high-density atomic systems, such as some collective excitations and new quantum phases.
As one of the most critical methods for optical super-resolved microscopy, stimulated emission depletion (STED) microscopy has been widely applied in biological and chemical fields, leading to the Nobel prize of 2014 in chemistry. In cold atomic systems, fast and high-resolution microscopy of individual atoms is crucial since it can provide direct information on the dynamics and correlations of the system. Here, we demonstrate nanosecond two-dimensional snapshots of a single trapped ion beyond the optical diffraction limit, by combining the main idea of STED with the quantum state transition control in cold atoms. We achieve a spatial resolution up to 175 nm and a time resolution up to 50 ns simultaneously using a NA=0.1 objective in the experiment, which is improved over ten times compared to direct fluorescence imaging. To show the potential of this method, we applied it to record the motion of the trapped ion and observe one cycle of the secular motion of the ion with a displacement detection sensitivity of 10 nm. Our method provides a powerful tool for probing particles' positions, momenta and correlations, as well as their dynamics in cold atomic systems.
Two methods of absorption imaging to detect cold atoms in a magnetic trap are implemented for a high-precision cold atom interferometer. In the first method, a probe laser which is in resonance with a cycle transition frequency is used to evaluate the quantity and distribution of the atom sample. In the second method, the probe laser is tuned to an open transition frequency, which stimulates a few and constant number of photons per atom. This method has a shorter interaction time and results in absorption images which are not affected by the magnetic field and the light field. We make a comparison of performance between these two imaging methods in the sense of parameters such as pulse duration, light intensity, and magnetic field strength. The experimental results show that the second method is more reliable when detecting the quantity and density profiles of the atoms. These results fit well to the theoretical analysis.