Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Towards optical frequency geopotential difference measurements via a flying drone

Benjamin P. Dix-Matthews, David R. Gozzard, Shane M. Walsh, Ayden McCann, Skevos Karpathakis, Alex M. Frost, Charles Gravestock, Sascha Schediwy

Published Apr 14, 2023• 11 citations
Publisher

Abstract

Geopotential and orthometric height differences between distant points can be measured via timescale comparisons between atomic clocks. Modern optical atomic clocks have residual instabilities on the order of 10^-18}, allowing height differences of around 1 cm to be measured. Frequency transfer via free-space optical links will be needed for measurements where linking the clocks via optical fiber is not possible, but requires line of sight between the clock locations, which is not always practical due to local terrain or over long distances. We present an active optical terminal, phase stabilization system, and phase compensation processing method robust enough to enable optical frequency transfer via a flying drone, greatly increasing the flexibility of free-space optical clock comparisons. We demonstrate a residual instability of 2.5x10^-18 after 3 s of integration, corresponding to a height difference of 2.3 cm, suitable for applications in geodesy, geology, and fundamental physics experiments.

DOI
10.1364/oe.483767

Related papers

Point-to-point stabilized optical frequency transfer with active optics

Benjamin P. Dix-Matthews, Sascha Schediwy, David R. Gozzard +8 more

Abstract Timescale comparison between optical atomic clocks over ground-to-space and terrestrial free-space laser links will have enormous benefits for fundamental and applied sciences. However, atmospheric turbulence creates phase noise and beam wander that degrade the measurement precision. Here we report on phase-stabilized optical frequency transfer over a 265 m horizontal point-to-point free-space link between optical terminals with active tip-tilt mirrors to suppress beam wander, in a compact, human-portable set-up. A phase-stabilized 715 m underground optical fiber link between the two terminals is used to measure the performance of the free-space link. The active optical terminals enable continuous, cycle-slip free, coherent transmission over periods longer than an hour. In this work, we achieve residual instabilities of 2.7 × 10 −6 rad 2 Hz −1 at 1 Hz in phase, and 1.6 × 10 −19 at 40 s of integration in fractional frequency; this performance surpasses the best optical atomic clocks, ensuring clock-limited frequency comparison over turbulent free-space links.

arXiv:2007.04985•Nature Communications•Jan 22, 2021•75 citations

Optical Frequency Transfer on the Order of 10−19 Fractional Frequency Instability over a 64 m Free-Space Link

Guoyong Wang, Zhangjian Lu, Xinwen Liang +3 more

High-precision time–frequency is widely used in time measurement, satellite navigation, scientific research, and other fields. With the rapid development of optical clock technology, the fractional frequency instability and uncertainty of optical clock have reached 10−18 orders of magnitude, which is expected to contribute to generating the International Atomic Time and may even be used to redefine the “second” in the future. Therefore, the long-distance transfer of time–frequency signals between optical atomic clocks is of great significance. Free-space optical frequency transfer technology is one of the important technologies for solving the space-based optical clock comparison because of its high transfer precision and easy networking characteristics. In order to solve the long-distance space-based optical clock comparison, this paper investigates a free-space active phase noise compensation method using an Acousto-Optic Modulator (AOM), based on the traditional optical fiber phase noise compensation scheme. This new method is more flexible and scalable than the optical fiber time–frequency transfer technology. The optical frequency transfer over a 64 m free-space link is demonstrated. The fractional frequency transfer instability during free running is 9.50 × 10−16 at 1 s, and 4.44 × 10−16 at 2000 s, and the fractional frequency instability after compensation is 7.10 × 10−17 at 1 s, 3.07 × 10−19 at 2000 s, which is about 1–3 orders of magnitude better than that in free running, and provides a feasible scheme for space-based optical clock comparison.

Photonics•Jun 22, 2024•3 citations

Ultrastable Free-Space Laser Links for a Global Network of Optical Atomic Clocks

David R. Gozzard, L. A. Howard, Benjamin P. Dix-Matthews +3 more

A global network of optical atomic clocks will enable unprecedented measurement precision in fields including tests of fundamental physics, dark matter searches, geodesy, and navigation. Free-space laser links through the turbulent atmosphere are needed to fully exploit this global network, by enabling comparisons to airborne and spaceborne clocks. We demonstrate frequency transfer over a 2.4 km atmospheric link with turbulence comparable to that of a ground-to-space link, achieving a fractional frequency stability of 6.1×10^{-21} in 300 s of integration time. We also show that clock comparison between ground and low Earth orbit will be limited by the stability of the clocks themselves after only a few seconds of integration. This significantly advances the technologies needed to realize a global timescale network of optical atomic clocks.

arXiv:2103.12909•Physical Review Letters•Jan 14, 2022•57 citations

All-optical link for direct comparison of distant optical clocks

Miho Fujieda, Motohiro Kumagai, Shigeo Nagano +3 more

We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of 2 × 10(-15) at 1 second and 4 × 10(-18) at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below 2 × 10(-15) at 1 second and 7 × 10(-17) at 1000 seconds. The system was available for the direct comparison of two distant (87)Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.

arXiv:1108.2775•Optics Express•Aug 11, 2011•93 citations

Free-space optical-frequency comparison over rapidly moving links

Shawn McSorley, Benjamin P. Dix-Matthews, Alex M. Frost +5 more

The comparison of optical clocks from ground to space will provide unprecedented tests of fundamental physics. Such comparison is limited, though, by the relative motion between the clocks. The experiment in this Letter demonstrates a method to compensate for Doppler shifts over a rapidly moving free-space optical drone link, using an electro-optic modulator. The authors demonstrate Doppler-shift compensation up to 18 MHz, providing a path toward ground-to-space optical comparison.

arXiv:2402.08899•Physical Review Applied•Feb 18, 2025•10 citations

Remote Transfer of Ultra-Stable Optical Frequency Reference using Active Cancellation of Fiber Induced Phase Noise

Manoj Das

Comparison of ultra-stable frequency references located in geographically distributed areas require a transfer technique, which offers stability of 10−17at 1 s over tens of kilometer. Such remote frequency transfer will allow comparing the optical frequency references of same or different atomic species (through a frequency comb bridge) for test of relativistic geodesy [1] or time variation of fundamental constants [2], and will contribute towards the database of frequency ratio measurements-an essential requirement for the re-definition of the SI second based on optical clocks [3]. It will also facilitate in creating an optical to microwave frequency link that can be used by various SI standards laboratory requiring stable microwave sources. In this paper, I discuss the modulated optical carrier wave based ultra-stable frequency reference transfer technique, and present a study of a laser interferometer based active fiber noise cancellation system and its applications.

URSI Regional Conference on Radio Science (URSI-RCRS)•Dec 1, 2022•1 citation
Geopotential and orthometric height differences between distant points can be measured via timescale comparisons between atomic clocks. Modern optical atomic clocks have residual instabilities on the order of 10^-18}, allowing height differences of around 1 cm to be measured. Frequency transfer via free-space optical links will be needed for measurements where linking the clocks via optical fiber is not possible, but requires line of sight between the clock locations, which is not always practical due to local terrain or over long distances. We present an active optical terminal, phase stabilization system, and phase compensation processing method robust enough to enable optical frequency transfer via a flying drone, greatly increasing the flexibility of free-space optical clock comparisons. We demonstrate a residual instability of 2.5x10^-18 after 3 s of integration, corresponding to a height difference of 2.3 cm, suitable for applications in geodesy, geology, and fundamental physics experiments.
Abstract Timescale comparison between optical atomic clocks over ground-to-space and terrestrial free-space laser links will have enormous benefits for fundamental and applied sciences. However, atmospheric turbulence creates phase noise and beam wander that degrade the measurement precision. Here we report on phase-stabilized optical frequency transfer over a 265 m horizontal point-to-point free-space link between optical terminals with active tip-tilt mirrors to suppress beam wander, in a compact, human-portable set-up. A phase-stabilized 715 m underground optical fiber link between the two terminals is used to measure the performance of the free-space link. The active optical terminals enable continuous, cycle-slip free, coherent transmission over periods longer than an hour. In this work, we achieve residual instabilities of 2.7 × 10 −6 rad 2 Hz −1 at 1 Hz in phase, and 1.6 × 10 −19 at 40 s of integration in fractional frequency; this performance surpasses the best optical atomic clocks, ensuring clock-limited frequency comparison over turbulent free-space links.
High-precision time–frequency is widely used in time measurement, satellite navigation, scientific research, and other fields. With the rapid development of optical clock technology, the fractional frequency instability and uncertainty of optical clock have reached 10−18 orders of magnitude, which is expected to contribute to generating the International Atomic Time and may even be used to redefine the “second” in the future. Therefore, the long-distance transfer of time–frequency signals between optical atomic clocks is of great significance. Free-space optical frequency transfer technology is one of the important technologies for solving the space-based optical clock comparison because of its high transfer precision and easy networking characteristics. In order to solve the long-distance space-based optical clock comparison, this paper investigates a free-space active phase noise compensation method using an Acousto-Optic Modulator (AOM), based on the traditional optical fiber phase noise compensation scheme. This new method is more flexible and scalable than the optical fiber time–frequency transfer technology. The optical frequency transfer over a 64 m free-space link is demonstrated. The fractional frequency transfer instability during free running is 9.50 × 10−16 at 1 s, and 4.44 × 10−16 at 2000 s, and the fractional frequency instability after compensation is 7.10 × 10−17 at 1 s, 3.07 × 10−19 at 2000 s, which is about 1–3 orders of magnitude better than that in free running, and provides a feasible scheme for space-based optical clock comparison.
A global network of optical atomic clocks will enable unprecedented measurement precision in fields including tests of fundamental physics, dark matter searches, geodesy, and navigation. Free-space laser links through the turbulent atmosphere are needed to fully exploit this global network, by enabling comparisons to airborne and spaceborne clocks. We demonstrate frequency transfer over a 2.4 km atmospheric link with turbulence comparable to that of a ground-to-space link, achieving a fractional frequency stability of 6.1×10^{-21} in 300 s of integration time. We also show that clock comparison between ground and low Earth orbit will be limited by the stability of the clocks themselves after only a few seconds of integration. This significantly advances the technologies needed to realize a global timescale network of optical atomic clocks.
We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of 2 × 10(-15) at 1 second and 4 × 10(-18) at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below 2 × 10(-15) at 1 second and 7 × 10(-17) at 1000 seconds. The system was available for the direct comparison of two distant (87)Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.
Comparison of ultra-stable frequency references located in geographically distributed areas require a transfer technique, which offers stability of 10−17at 1 s over tens of kilometer. Such remote frequency transfer will allow comparing the optical frequency references of same or different atomic species (through a frequency comb bridge) for test of relativistic geodesy [1] or time variation of fundamental constants [2], and will contribute towards the database of frequency ratio measurements-an essential requirement for the re-definition of the SI second based on optical clocks [3]. It will also facilitate in creating an optical to microwave frequency link that can be used by various SI standards laboratory requiring stable microwave sources. In this paper, I discuss the modulated optical carrier wave based ultra-stable frequency reference transfer technique, and present a study of a laser interferometer based active fiber noise cancellation system and its applications.