Accumulated photon echoes were observed in
Nd3+-doped silicate glass by using coherent and incoherent light, and it was theoretically and experimentally verified that the time resolution is determined not by the pulse width but by the correlation time of the excitation field. Even by using a cw laser, instead of a mode-locked laser, a subpicosecond time resolution was obtained when it was operated with a broad and smooth spectrum. The broadest output spectrum, and hence the highest time resolution, was attained when the dye laser was pumped by a mode-locked
Ar+ laser, and their cavity lengths were mismatched by a few \ensuremath{\mu}m. In an experiment with a resolution time of 220 fsec, a new very fast decay was observed in the echo decay curve besides a slower decay already reported.
An analytic theory and experimental studies of the accumulated photon echo is presented. We define a temporal correlation function
G~ of the excitation field E ( t ) as
G~(τ,t)=(1/T1)∫0∞dt′E(t−t′)E(t−t′−τ)⋅exp(−t′/T1), where T 1 is the population relaxation time of the sample, and call the width of
G~ with respect to τ a temporal correlation time
τ~c(t). It is proved that the echo intensity is written by the temporal correlation functions when (1) T 1 and the duration of the excitation light τ p are much longer than
τ~c(t) in order to make the function
G~((τ,t) well-defined, (2) T 1 and τ p are much longer than the homogeneous dephasing time T 2 , and (3) one can find a time interval Δ t such that
G~(τ,t) does not change much between t and t + Δ t , where
Δt≫τ~c. Then we can show that the time resolution of the accumulated photon echo is determined by the averaged
τ~c(t) over an interval of the integration of the echo signal. This discussion is valid for any excitation source if the above conditions are satisfied, and applies to almost all cases of the practical accumulated photon echo experiment. A discussion is also made on the spurious spike on the echo decay curve near zero delay time that appeared in an experiment with a high time resolution in Nd 3+ -doped silicate glass. It is shown that the most probable cause for this spike is uncorrelated inhomogeneous broadenings of the resonant lines of neodymium ions.
It has been recently pointed out that incoherent light can be used to generate coherent optical transients and that there are decided advantages in using such broad-band non-laser source to achieve very high time resolution {1,2}. When a light pulse and its time-delayed replica interact with a sample to produce the non-linear optical response, the ultimate time resolution should identify with the correlation time τC of the light field rather than with the pulse duration τL. The situation where τC ≪ τL is easily obtained with broad-band incoherent light sources. Time resolution in the femtosecond range is then attainable using nanosecond light pulses. This has been recently demonstrated through the observation of the relaxation of photon echoes in Nd3+-doped silicate glass {1,2}. In these cases, attention is focused on the measurement of fast homogeneous decay rates and the inhomogeneous broadening ΩD is assumed to be much larger than the spectral width of the excitation light.
Accumulated photon echoes have been observed by use of a light-emitting diode. This is to our knowledge the first observation of photon echoes that are excited by a nonlaser light source. In the incoherent-light photon echo, the time resolution is equal to the inverse of the overall spectral width of the excitation light. Therefore we can easily get a high time resolution by using nonlaser light with a broad spectrum. Moreover the use of nonlaser light in the photon-echo experiment will extend the technique into wavelength regions where lasers are not currently available.
Accumulated photon echoes (APE) were used to measure the dephasing rates of Nd3+ in various inorganic glasses as a function of excitation wavelength, sample temperature, and laser power. Although dephasing processes of optical transitions in solids are of considerable interest, they are poorly understood, largely due to the lack of experimental data on femtosecond and picosecond time scales. The APE technique using sub-picosecond laser sources has made it possible to measure in the time domain dephasing rates of inhomogeneously broadened transitions in amorphous systems.1,2