Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annual Meeting Optical Society of America

Photocount statistics of continuous wave squeezed light

Zhu Chang, Carlton M. Caves

Published Jan 1, 1989• 0 citations
Publisher

Abstract

Photon number probabilities for a single squeezed mode can exhibit sub-Poissonian or super-Poissonian statistics and can display sharp oscillations in appropriate conditions. We consider photocount probabilities for cw squeezed light occupying a single transverse mode. The squeezing spectrum is assumed to be flat over a bandwidth B, centered at optical frequency Ω/2π. We compute single-fold photoelectron probabilities for a counting interval of duration T. We proceed by decomposing the single transverse mode into a complete set of longitudinal wave-packet modes, defined in terms of prolate spheroidal wave functions. Each of these wave-packet modes is in a separate squeezed state. The Kelley-Kleiner photocount probability can then be written in terms of single-mode photon-number probabilities for these wave packet modes, which are detected with varying efficiencies. We need consider only a finite number of modes, because only about BT of the modes have high enough efficiency to contribute significantly to the photocount probability.

DOI
10.1364/oam.1989.wq5

Related papers

Photocount distributions for continuous-wave squeezed light

Chang Jun Zhu, Carlton M. Caves

For continuous-wave (cw) squeezed light that has a monochromatic mean field and a rectangular squeezing spectrum covering bandwidth B, we calculate the photocount distribution for a counting time T. The nonclassical oscillations in the photon-number distribution of single-mode squeezed light have reduced visibility in the cw photostatics and often disappear entirely. The even-odd oscillations associated a with single-mode squeezed vacuum are absent for BT\ensuremath{\ll}1, but for BT\ensuremath{\gtrsim}1 they appear in the cw photocount distribution with reduced visibility under appropriate conditions. The oscillations associated with a single-mode squeezed state that has a mean complex amplitude disappear from the cw photostatistics for all counting times.

Physical Review A•Dec 1, 1990•37 citations

Photocount statistics of broadband squeezed states

Carlton M. Caves

Consider a photodetector characterized by two bandwidths: (i) an optical bandwidth over which it has nearly unity quantum efficiency and (ii) a much smaller electronic bandwidth, the bandwidth over which it produces beats between different frequencies. Direct onto the photodetector a light beam which is the superposition of two parts: (i) an intense, nearly monochromatic carrier wave at some carrier frequency and (ii) a squeezed state with zero mean field, which is squeezed in the broadband (multimode) sense (correlation between frequencies located symmetrically above and below the carrier frequency) within some bandwidth about the carrier. The standard statements are that, if the squeezed quadrature is in phase with the carrier (amplitude-modulation squeezing), one will see sub-Poissonian photocount statistics, and if the squeezed quadrature is out of phase with the carrier (phase-modulation squeezing), one will see super-Poissonian statistics. Bandwidth considerations impact these statements in the following way: the only part of the squeezing that is relevant for decreasing or increasing the counting noise is that part that lies within an electronic bandwidth of the carrier frequency; to see the maximum decrease or increase, one must squeeze over the entire electronic bandwidth. These conclusions require modification if the carrier wave is not sufficiently intense.

Annual Meeting Optical Society of America•Jan 1, 1985•0 citations

Photon-counting statistics of multimode squeezed light

Jianming Huang, Prem Kumar

We present photon-counting distributions of multimode squeezed light of bandwidth B. Such light, for example, is generated by the intracavity parametric down-converter of Wu et al. [Phys. Rev. Lett. 57, 2520 (1986)], which has now become a standard source for generating highly squeezed light. By expanding the electric-field operator into relevant modes over the counting interval T and applying the Bogoliubov transformation that generates squeezing, we calculate the photon-counting distributions under both BT\ensuremath{\gg}1 and BT\ensuremath{\ll}1 conditions. We find that the probability for counting an odd number of photons is identically zero under the former condition, whereas the latter is equivalent to having a photodetector with quantum efficiency that is much less than unity.

Physical Review A•Aug 1, 1989•22 citations

Sub- and super-Poissonian photon statistics of single-molecule fluorescence blinking

Игорь Сергеевич Осадько

An analysis of intermittent fluorescence is presented for a single molecule driven by a continuous-wave laser field. The interruptions of fluorescence are caused by transition of the molecule to a triplet state. A method previously developed to calculate photon distribution for continuous-wave fluorescence is applied to analyze photon statistics of fluorescence blinking. The probability w N (T) of counting N photons over a time interval T is derived for intermittent fluorescence. The photons counted over relatively short intervals are found to have a sub-Poissonian (narrower than Poisson) distribution. The photon distribution over intervals longer than the mean off time has a complicated form with two maxima; i.e., a super-Poissonian (wider than Poisson) distribution is obtained.

Journal of Experimental and Theoretical Physics•Jun 1, 2007•9 citations

Photocount statistics for pump-noise-suppressed lasers

Chang Jun Zhu, Carlton M. Caves

A laser with a Poissonian random pump, operated far above threshold, has Poissonian statistics both for the intracavity photon number and for extracavity photocounts. We analyze a pump-noise-suppressed laser using the positive P representation. When the pump noise is suppressed below a critical level, the intracavity photon-number distribution becomes sub-Poissonian.1,2 When the spontaneous decay of the upper lasing level is also eliminated, intracavity photon-number fluctuations can be diminished by a factor up to half. For counting times much shorter than the cavity decay time, the extracavity photocount statistics are essentially Poissonian, since cavity decay dominates. For counting times comparable with or larger than the cavity lifetime, the extracavity photocount statistics become sub-Poissonian. In the limit that intracavity photon-number fluctuations are diminished by one half, the extracavity photocount noise can be completely suppressed for counting times much longer than the cavity lifetime. The cavity mode occupies an incoherent superposition of two states 180° out of phase, both of which diffuse in phase. In the microlaser regime, quantum diffusion between these two states can result in 180° phase jumps, which are in addition to ordinary phase diffusion.

Annual Meeting Optical Society of America•Jan 1, 1991•0 citations

Spatial behavior of nonclassic light

Mikhail I. Kolobov

Summary form only given.It has previously been shown that a traveling-wave optical parametric amplifier can generate multimode squeezed states of light. Homodyne detection of multimode squeezed light, under certain physical conditions, results in sub-Poissonian statistics of photons not only in time but also in the transverse plane of the light beam. Of particular relevance to applications is a situation when the cross section of the light beam contains several nonoverlapping areas with sub-Poissonian statistics of photons within each of them. Under photodetection of such a beam of light, several sub-shot-noise photocurrents can be produced according to the number of independent areas with sub-Poissonian statistics. This is in drastic contrast to the case of a single-mode sub-Poissonian light beam, where any attempt to collect light only from a part of the beam deteriorates the degree of shot-noise reduction. This property of multimode squeezed light opens a range of new interesting applications in optical imaging, optical parallel processing of information, parallel computing, and many other phenomena where it is desirable to have the regular statistics of photons across the transverse plane of the electromagnetic wave. We describe the application of multimode squeezed light in sub-shot-noise microscopy, noiseless amplifications of optical images, and optical imaging. We also consider the possibility of improving the resolution in optical imaging and microscopy beyond the Rayleigh limit via multimode squeezed light.

Conference on Lasers and Electro-Optics•Nov 27, 2002•0 citations
Photon number probabilities for a single squeezed mode can exhibit sub-Poissonian or super-Poissonian statistics and can display sharp oscillations in appropriate conditions. We consider photocount probabilities for cw squeezed light occupying a single transverse mode. The squeezing spectrum is assumed to be flat over a bandwidth B, centered at optical frequency Ω/2π. We compute single-fold photoelectron probabilities for a counting interval of duration T. We proceed by decomposing the single transverse mode into a complete set of longitudinal wave-packet modes, defined in terms of prolate spheroidal wave functions. Each of these wave-packet modes is in a separate squeezed state. The Kelley-Kleiner photocount probability can then be written in terms of single-mode photon-number probabilities for these wave packet modes, which are detected with varying efficiencies. We need consider only a finite number of modes, because only about BT of the modes have high enough efficiency to contribute significantly to the photocount probability.
For continuous-wave (cw) squeezed light that has a monochromatic mean field and a rectangular squeezing spectrum covering bandwidth B, we calculate the photocount distribution for a counting time T. The nonclassical oscillations in the photon-number distribution of single-mode squeezed light have reduced visibility in the cw photostatics and often disappear entirely. The even-odd oscillations associated a with single-mode squeezed vacuum are absent for BT\ensuremath{\ll}1, but for BT\ensuremath{\gtrsim}1 they appear in the cw photocount distribution with reduced visibility under appropriate conditions. The oscillations associated with a single-mode squeezed state that has a mean complex amplitude disappear from the cw photostatistics for all counting times.
Consider a photodetector characterized by two bandwidths: (i) an optical bandwidth over which it has nearly unity quantum efficiency and (ii) a much smaller electronic bandwidth, the bandwidth over which it produces beats between different frequencies. Direct onto the photodetector a light beam which is the superposition of two parts: (i) an intense, nearly monochromatic carrier wave at some carrier frequency and (ii) a squeezed state with zero mean field, which is squeezed in the broadband (multimode) sense (correlation between frequencies located symmetrically above and below the carrier frequency) within some bandwidth about the carrier. The standard statements are that, if the squeezed quadrature is in phase with the carrier (amplitude-modulation squeezing), one will see sub-Poissonian photocount statistics, and if the squeezed quadrature is out of phase with the carrier (phase-modulation squeezing), one will see super-Poissonian statistics. Bandwidth considerations impact these statements in the following way: the only part of the squeezing that is relevant for decreasing or increasing the counting noise is that part that lies within an electronic bandwidth of the carrier frequency; to see the maximum decrease or increase, one must squeeze over the entire electronic bandwidth. These conclusions require modification if the carrier wave is not sufficiently intense.
We present photon-counting distributions of multimode squeezed light of bandwidth B. Such light, for example, is generated by the intracavity parametric down-converter of Wu et al. [Phys. Rev. Lett. 57, 2520 (1986)], which has now become a standard source for generating highly squeezed light. By expanding the electric-field operator into relevant modes over the counting interval T and applying the Bogoliubov transformation that generates squeezing, we calculate the photon-counting distributions under both BT\ensuremath{\gg}1 and BT\ensuremath{\ll}1 conditions. We find that the probability for counting an odd number of photons is identically zero under the former condition, whereas the latter is equivalent to having a photodetector with quantum efficiency that is much less than unity.
An analysis of intermittent fluorescence is presented for a single molecule driven by a continuous-wave laser field. The interruptions of fluorescence are caused by transition of the molecule to a triplet state. A method previously developed to calculate photon distribution for continuous-wave fluorescence is applied to analyze photon statistics of fluorescence blinking. The probability w N (T) of counting N photons over a time interval T is derived for intermittent fluorescence. The photons counted over relatively short intervals are found to have a sub-Poissonian (narrower than Poisson) distribution. The photon distribution over intervals longer than the mean off time has a complicated form with two maxima; i.e., a super-Poissonian (wider than Poisson) distribution is obtained.
A laser with a Poissonian random pump, operated far above threshold, has Poissonian statistics both for the intracavity photon number and for extracavity photocounts. We analyze a pump-noise-suppressed laser using the positive P representation. When the pump noise is suppressed below a critical level, the intracavity photon-number distribution becomes sub-Poissonian.1,2 When the spontaneous decay of the upper lasing level is also eliminated, intracavity photon-number fluctuations can be diminished by a factor up to half. For counting times much shorter than the cavity decay time, the extracavity photocount statistics are essentially Poissonian, since cavity decay dominates. For counting times comparable with or larger than the cavity lifetime, the extracavity photocount statistics become sub-Poissonian. In the limit that intracavity photon-number fluctuations are diminished by one half, the extracavity photocount noise can be completely suppressed for counting times much longer than the cavity lifetime. The cavity mode occupies an incoherent superposition of two states 180° out of phase, both of which diffuse in phase. In the microlaser regime, quantum diffusion between these two states can result in 180° phase jumps, which are in addition to ordinary phase diffusion.
Summary form only given.It has previously been shown that a traveling-wave optical parametric amplifier can generate multimode squeezed states of light. Homodyne detection of multimode squeezed light, under certain physical conditions, results in sub-Poissonian statistics of photons not only in time but also in the transverse plane of the light beam. Of particular relevance to applications is a situation when the cross section of the light beam contains several nonoverlapping areas with sub-Poissonian statistics of photons within each of them. Under photodetection of such a beam of light, several sub-shot-noise photocurrents can be produced according to the number of independent areas with sub-Poissonian statistics. This is in drastic contrast to the case of a single-mode sub-Poissonian light beam, where any attempt to collect light only from a part of the beam deteriorates the degree of shot-noise reduction. This property of multimode squeezed light opens a range of new interesting applications in optical imaging, optical parallel processing of information, parallel computing, and many other phenomena where it is desirable to have the regular statistics of photons across the transverse plane of the electromagnetic wave. We describe the application of multimode squeezed light in sub-shot-noise microscopy, noiseless amplifications of optical images, and optical imaging. We also consider the possibility of improving the resolution in optical imaging and microscopy beyond the Rayleigh limit via multimode squeezed light.