Annual Meeting Optical Society of America

Direct measurement of stimulated emission in two-photon downconversion

L. J. Wang, X. Y. Zou, L. Mandeļ

Published Jan 1, 1990• 0 citations
Publisher

Abstract

Measurements have been made of the rate at which signal photons are produced in a nonlinear crystal in the process of parametric downconversion, when a coherent light beam from a He:Ne laser is injected into the crystal in the direction of the conjugate-idler photons. The latter provides a stimulating field for the downconversion. When the phase matching condition inside the nonlinear medium is satisfied, the rate of downconversion is enhanced by the presence of the He–Ne laser beam by a factor of the form 1 + βIi, where li is the intensity of the He:Ne laser beam. The effect of defocusing either the pump beam or the He–Ne idler beam is investigated. Possible use of this phenomenon to study the photon amplifier with single-photon input will be discussed.

DOI
10.1364/oam.1990.ml1

Related papers

Photon amplification by parametric downconversion

Z. Y. Ou, L. J. Wang, L. Mandeļ

We investigate the theory of the process in which an idler photon emitted spontaneously from a nonlinear crystal in the process of parametric downconversion serves as idler input to a second downconverter. The signal photon from this second crystal is then detected in coincidence with the signal photon from the first crystal, which provides the time reference. We show that the first idler photon can induce a stimulated downconversion in the second crystal, which serves as a photon amplifier, and we calculate the ratio of the stimulated to the spontaneous emission probability.

Journal of the Optical Society of America B•Feb 1, 1990•12 citations

Intensity correlations in parametric downconversion

Stephen R. Friberg, C. K. Hong, L. Mandeļ

When a laser beam interacts with a nonlinear crystal, some of the incident photons fission into two lower frequency signal and idler photons through the process of spontaneous parametric downconversion. It is shown that, as a result of the strong positive correlation between signal and idler photons, the normalized intensity cross-correlation function λ12(τ) should be inversely proportional to the downconverted light intensity and ideally should be given by the inverse of the mean number of photons counted in the resolving time. This unusual relationship, which is a reflection of the quantum mechanical character of the downconverted optical field, has been confirmed in photoelectric counting measurements. The experiment makes use of the light from an argon-ion laser oscillating at 351.1 nm interacting with an 8-cm long crystal of KDP. The downconverted light is extracted at 633.5 and 788.0 nm in two directions that satisfy the phase-matching condition and is allowed to fall on two counting photomultipliers. The output pulses are fed to a time-to-digital converter that yields the cross-correlation function.

Annual Meeting Optical Society of America•Jan 1, 1985•0 citations

Time-Resolved Upconversion of Entangled Photon Pairs

Kevin A. O’Donnell, Alfred B. U’Ren

In the process of spontaneous parametric downconversion, photons from a pump field are converted to signal and idler photon pairs in a nonlinear crystal. The reversed process, or upconversion of these pairs back to single photons in a second crystal, is also possible. Here, we present experimental measurements of the upconversion rate with a controlled time delay introduced between the signal and idler photons. As a function of delay, this rate presents a full width at half maximum of 27.9 fs under our experimental conditions[1].

Frontiers in Optics•Jan 1, 2009•2 citations

Coherence in two-photon down-conversion induced by a laser

L. J. Wang, X. Y. Zou, L. Mandeļ

Normally, the signal and idler photons produced in the process of parametric down- conversion exhibit no second-order interference. However, in the presence of an external laser beam that follows the path of the signal photon and induces stimulated down-conversions, one would expect coherence to develop between the down-converted signal and idler beams. We have demonstrated the existence of this phenomenon in an experiment with two down-converters pumped by similar pump beams, in which two mutually coherent laser beams followed the paths of the two down-converted signal photons and induced coherence between the two down- converted idler beams. The induced coherence gives rise to observable interference effects, which are presented.

Annual Meeting Optical Society of America•Jan 1, 1990•1 citation

Coherence in two-photon down-conversion induced by a laser

Z. Y. Ou, L. J. Wang, X. Y. Zou +1 more

We discuss the situation in which idler beams from two parametric down-converter crystals are allowed to interfere. We show that, when two mutually coherent signal beams derived from a common laser are injected into the down-converters, the two idler beams can become mutually coherent also. Moreover, the resulting interference pattern can, in principle, have 100% visibility when the number of injected photons per unit down-converter bandwidth is large. This is just the condition for stimulated down-conversion to dominate over spontaneous down-conversion.

Physical Review A•Feb 1, 1990•53 citations

Observation of induced coherence in two-photon downconversion

L. J. Wang, X. Y. Zou, L. Mandeļ

By using two mutually coherent light beams of adjustable intensity to induce downconversions of the signal beams in two similar nonlinear crystals and then allowing the two idlers to interfere, we measure the variation of the induced degree of coherence as a function of inducing intensity. The key parameter N is the average photon occupation number per mode of the inducing field. We show experimentally that the induced degree of coherence is given by N/(N+1), as is expected theoretically.

Journal of the Optical Society of America B•May 1, 1991•44 citations
Measurements have been made of the rate at which signal photons are produced in a nonlinear crystal in the process of parametric downconversion, when a coherent light beam from a He:Ne laser is injected into the crystal in the direction of the conjugate-idler photons. The latter provides a stimulating field for the downconversion. When the phase matching condition inside the nonlinear medium is satisfied, the rate of downconversion is enhanced by the presence of the He–Ne laser beam by a factor of the form 1 + βIi, where li is the intensity of the He:Ne laser beam. The effect of defocusing either the pump beam or the He–Ne idler beam is investigated. Possible use of this phenomenon to study the photon amplifier with single-photon input will be discussed.
We investigate the theory of the process in which an idler photon emitted spontaneously from a nonlinear crystal in the process of parametric downconversion serves as idler input to a second downconverter. The signal photon from this second crystal is then detected in coincidence with the signal photon from the first crystal, which provides the time reference. We show that the first idler photon can induce a stimulated downconversion in the second crystal, which serves as a photon amplifier, and we calculate the ratio of the stimulated to the spontaneous emission probability.
When a laser beam interacts with a nonlinear crystal, some of the incident photons fission into two lower frequency signal and idler photons through the process of spontaneous parametric downconversion. It is shown that, as a result of the strong positive correlation between signal and idler photons, the normalized intensity cross-correlation function λ12(τ) should be inversely proportional to the downconverted light intensity and ideally should be given by the inverse of the mean number of photons counted in the resolving time. This unusual relationship, which is a reflection of the quantum mechanical character of the downconverted optical field, has been confirmed in photoelectric counting measurements. The experiment makes use of the light from an argon-ion laser oscillating at 351.1 nm interacting with an 8-cm long crystal of KDP. The downconverted light is extracted at 633.5 and 788.0 nm in two directions that satisfy the phase-matching condition and is allowed to fall on two counting photomultipliers. The output pulses are fed to a time-to-digital converter that yields the cross-correlation function.
In the process of spontaneous parametric downconversion, photons from a pump field are converted to signal and idler photon pairs in a nonlinear crystal. The reversed process, or upconversion of these pairs back to single photons in a second crystal, is also possible. Here, we present experimental measurements of the upconversion rate with a controlled time delay introduced between the signal and idler photons. As a function of delay, this rate presents a full width at half maximum of 27.9 fs under our experimental conditions[1].
Normally, the signal and idler photons produced in the process of parametric down- conversion exhibit no second-order interference. However, in the presence of an external laser beam that follows the path of the signal photon and induces stimulated down-conversions, one would expect coherence to develop between the down-converted signal and idler beams. We have demonstrated the existence of this phenomenon in an experiment with two down-converters pumped by similar pump beams, in which two mutually coherent laser beams followed the paths of the two down-converted signal photons and induced coherence between the two down- converted idler beams. The induced coherence gives rise to observable interference effects, which are presented.
We discuss the situation in which idler beams from two parametric down-converter crystals are allowed to interfere. We show that, when two mutually coherent signal beams derived from a common laser are injected into the down-converters, the two idler beams can become mutually coherent also. Moreover, the resulting interference pattern can, in principle, have 100% visibility when the number of injected photons per unit down-converter bandwidth is large. This is just the condition for stimulated down-conversion to dominate over spontaneous down-conversion.