Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annual Meeting Optical Society of America

Equivalence of twin beams and squeezed states in a nondegenerate optical parametric amplifier

Chonghoon Kim, Prem Kumar

Published Jan 1, 1992• 0 citations
Publisher

Abstract

Twin beams generated from a nondegenerate optical parametric amplifier (NOPA) of gaing possess1 an intensity correlation that falls below the quantum limit by (2g – 1). This occurs whenever the input idler to the NOPA is in the vacuum state. Such input is practically advantageous because it makes the NOPA output intensities phase insensitive. When a non-vacuum idler input state is chosen, the NOPA output intensities become phase sensitive. For a proper input state and a suitable pump phase the output intensity correlation falls below the quantum limit by ( g + g − 1 ) 2 , which is 3 dB superior to the vacuum-idler-input result for g >> 1 and is equivalent to the quantum-noise reduction obtainable from a squeezed state generated with the same gain. Thus the sensitivity improvement achievable with NOPA twin beams by using direct detection is equivalent to that obtainable with squeezed states by using homodyne detection. The above equivalence also provides a new scheme for the generation of pulsed squeezed light that, in addition to being simple, automatically generates a matched local oscillator2 for homodyne detection of the squeezed pulses.

DOI
10.1364/oam.1992.fv3

Related papers

Enhancement in quantum noise correlation between the two outputs of a nondegenerate optical amplifier with a non-vacuum state idler input

Chonghoon Kim

The theoretical limit of the noise correlation between the signal and idler outputs of a nondegenerate optical parametric amplifier (NOPA) with a coherent state signal and vacuum state idler input can be enhanced if a non-vacuum coherent state idler input is employed. By choosing a balanced signal and idler input, the noise correlation is $1/{({\root}g + {\root}{g-1})}^2$ , where g is the intensity gain of the NOPA, and that is superior to the prediced outputs with single signal input by approximately 3dB. The result is applicable to all the schemes that use the NOPA to produce a sub-shot noise light generation such as feed-back or feed-forward control.

Journal of the Optical Society of Korea•Mar 1, 1997•3 citations

Quantum-noise reduction with a Q-switched laser

Orhan Aytür, Prem Kumar

Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

Pulsed twin beams of light

Orhan Aytür, Prem Kumar

Pulsed twin beams of light have been generated using an optical-parametric amplifier that is pumped by the second harmonic of a mode-locked and Q-switched neodymium:yttrium aluminum garnet laser. The intensity noise levels on the direct-detected signal and idler beams are found to be correlated by more than 15 dB, and the subtracted noise falls below the quantum limit by more than 6 dB (75%). To our knowledge, this is the first observation of pulsed twin beams of light, and yields the highest quantum-noise reduction observed in any experiment to date. Our measurements are in excellent agreement with the quantum theory of a nondegenerate optical-parametric amplifier.

Physical Review Letters•Sep 24, 1990•182 citations

Tunable squeezed-light generation from twin beams using an optical-phase feed-forward scheme

Chonghoon Kim, Prem Kumar

We analyze an optical-phase feed-forward scheme to produce a squeezed-light beam from intensity-correlated twin beams generated by nondegenerate parametric amplification. The quadrature measurement of the idler beam at the output of the parametric amplifier is linearly fed forward onto the output signal beam with an electro-optic phase modulator. The minimum available squeezing factor is shown to be 1/(2g - 1), where g is the parametric amplifier gain, and is equal to the nonclassical intensity-noise reduction factor of the original twin beams at the output of the parametric amplifier. By changing the frequency of the input signal beam, one can generate tunable squeezed light with this scheme for application in precision spectroscopy.

Optics Letters•May 15, 1991•9 citations

Quantum amplification and quantum optical tapping with squeezed states and correlated quantum states

Z. Y. Ou, Silvania F. Pereira, Harry J. Kimble

Quantum fluctuations in a nondegenerate optical parametric amplifier (NOPA) are investigated experimentally with a squeezed state coupled into the internal idler mode of the NOPA. Reductions of the inherent quantum noise of the amplifier are observed with a minimum noise level 0.7 dB below the usual noise level of the amplifier with its idler mode in a vacuum state. With two correlated quantum fields as the amplifier's inputs and proper adjustment of the gain of the amplifier, it is shown that the amplifier's intrinsic quantum noise can be completely suppressed so that noise-free amplification is achieved. It is also shown that the NOPA, when coupled to either a squeezed state or a nonclassically correlated state, can realize quantum tapping of optical information.

•May 1, 1994•0 citations

Precision measurements with twin beams of light

Prem Kumar

The generation of twin beams of light from an optical parametric amplifier (OPA) pumped by the second harmonic of a mode-locked and Q-Switched Nd:YAG laser has recently been reported.1 The intensity noises on the direct- detected signal and idler beams at the output of the OPA were observed to be correlated by more than 15 dB, and the subtracted noise fell below the quantum limit by up to 7 dB (80%). With the same OPA it is much harder to generate and detect a highly squeezed beam of light.

Quantum Electronics and Laser Science Conference•May 12, 1991•0 citations
Twin beams generated from a nondegenerate optical parametric amplifier (NOPA) of gaing possess1 an intensity correlation that falls below the quantum limit by (2g – 1). This occurs whenever the input idler to the NOPA is in the vacuum state. Such input is practically advantageous because it makes the NOPA output intensities phase insensitive. When a non-vacuum idler input state is chosen, the NOPA output intensities become phase sensitive. For a proper input state and a suitable pump phase the output intensity correlation falls below the quantum limit by ( g + g − 1 ) 2 , which is 3 dB superior to the vacuum-idler-input result for g >> 1 and is equivalent to the quantum-noise reduction obtainable from a squeezed state generated with the same gain. Thus the sensitivity improvement achievable with NOPA twin beams by using direct detection is equivalent to that obtainable with squeezed states by using homodyne detection. The above equivalence also provides a new scheme for the generation of pulsed squeezed light that, in addition to being simple, automatically generates a matched local oscillator2 for homodyne detection of the squeezed pulses.
The theoretical limit of the noise correlation between the signal and idler outputs of a nondegenerate optical parametric amplifier (NOPA) with a coherent state signal and vacuum state idler input can be enhanced if a non-vacuum coherent state idler input is employed. By choosing a balanced signal and idler input, the noise correlation is $1/{({\root}g + {\root}{g-1})}^2$ , where g is the intensity gain of the NOPA, and that is superior to the prediced outputs with single signal input by approximately 3dB. The result is applicable to all the schemes that use the NOPA to produce a sub-shot noise light generation such as feed-back or feed-forward control.
Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.
Pulsed twin beams of light have been generated using an optical-parametric amplifier that is pumped by the second harmonic of a mode-locked and Q-switched neodymium:yttrium aluminum garnet laser. The intensity noise levels on the direct-detected signal and idler beams are found to be correlated by more than 15 dB, and the subtracted noise falls below the quantum limit by more than 6 dB (75%). To our knowledge, this is the first observation of pulsed twin beams of light, and yields the highest quantum-noise reduction observed in any experiment to date. Our measurements are in excellent agreement with the quantum theory of a nondegenerate optical-parametric amplifier.
We analyze an optical-phase feed-forward scheme to produce a squeezed-light beam from intensity-correlated twin beams generated by nondegenerate parametric amplification. The quadrature measurement of the idler beam at the output of the parametric amplifier is linearly fed forward onto the output signal beam with an electro-optic phase modulator. The minimum available squeezing factor is shown to be 1/(2g - 1), where g is the parametric amplifier gain, and is equal to the nonclassical intensity-noise reduction factor of the original twin beams at the output of the parametric amplifier. By changing the frequency of the input signal beam, one can generate tunable squeezed light with this scheme for application in precision spectroscopy.
Quantum fluctuations in a nondegenerate optical parametric amplifier (NOPA) are investigated experimentally with a squeezed state coupled into the internal idler mode of the NOPA. Reductions of the inherent quantum noise of the amplifier are observed with a minimum noise level 0.7 dB below the usual noise level of the amplifier with its idler mode in a vacuum state. With two correlated quantum fields as the amplifier's inputs and proper adjustment of the gain of the amplifier, it is shown that the amplifier's intrinsic quantum noise can be completely suppressed so that noise-free amplification is achieved. It is also shown that the NOPA, when coupled to either a squeezed state or a nonclassically correlated state, can realize quantum tapping of optical information.