The opportunities afforded by near-term quantum computers to calculate the ground-state properties of small molecules depend on the structure of the computational ansatz as well as the errors induced by device noise. Here we investigate the behavior of these noisy quantum circuits using numerical simulations to estimate the accuracy and fidelity of the prepared quantum states relative to the ground truth obtained by conventional means. We implement several different types of ansatz circuits derived from unitary coupled cluster theory for the purposes of estimating the ground-state energy of sodium hydride using the variational quantum eigensolver algorithm. We show how relative error in the energy and the fidelity scale with the levels of gate-based noise, the internuclear configuration, the ansatz circuit depth, and the parameter optimization methods.
The opportunities afforded by near-term quantum computers to calculate the ground-state properties of small molecules depend on the structure of the computational ansatz as well as the errors induced by device noise. Here we investigate the behavior of these noisy quantum circuits using numerical simulations to estimate the accuracy and fidelity of the prepared quantum states relative to the ground truth obtained by conventional means. We implement several different types of ansatz circuits derived from unitary coupled cluster theory for the purposes of estimating the ground-state energy of sodium hydride using the variational quantum eigensolver algorithm. We show how relative error in the energy and the fidelity scale with the levels of gate-based noise, the internuclear configuration, the ansatz circuit depth, and the parameter optimization methods.
Abstract The opportunities afforded by near-term quantum computers to calculate the ground-state properties of small molecules depend on the structure of the computational ansatz as well as the errors induced by device noise. Here we investigate the behavior of these noisy quantum circuits using numerical simulations to estimate the accuracy and fidelity of the prepared quantum states relative to the ground truth obtained by conventional means. We implement several different types of ansatz circuits derived from unitary coupled cluster theory for the purposes of estimating the ground-state energy of sodium hydride using the variational quantum eigensolver algorithm. We show how relative error in the energy and the fidelity scale with the levels of gate-based noise, the internuclear configuration, the ansatz circuit depth, and the parameter optimization methods.
This is a case study of the variational quantum eigensolver (VQE) method using numerical simulations to test the influence of noise on the accuracy of the underlying circuit ansatz. We investigate a computational chemistry application of VQE to calculate the electronic ground state and its energy for Sodium Hydride (NaH), a prototypical two-electron problem. Using a one-parameter ansatz derived from unitary coupled cluster (UCC) theory, we simulate the effects of noise on the energy expectation value and variance with respect to the ansatz parameter. These numerical simulations provide insights into the accuracy of the prepared quantum state and the efficiency of the classical optimizer that iteratively refines the ansatz. We conduct a comparative study between analytical results derived for the UCC ansatz in the absence of noise and the noisy numerical simulation results obtained using an isotropic depolarizing noise model for each gate. We also compare the relative increase in noise on logically equivalent UCC ansatz circuits generated by randomized compiling. Notably, we observe that the intrinsic variance in the energy due to the simplicity of the ansatz itself compares with the noise induced by the bare circuit.
In this work, we present a comprehensive comparative study between two different Ansatz quantum circuits , specifically the Unitary Vibrational Coupled Cluster (UVCC) and the Compact Heuristic Circuit (CHC) with use in computational chemistry . By incorporating these circuits into the Variational Quantum Eigensolver (VQE), we aim to find the vibrational ground state energy of small molecules. Our results, obtained using both the UVCC and CHC ansatzes with and without quantum hardware noise, are benchmarked against classical computational methods for energy state determination. We emphasize the efficiency and accuracy of the CHC Ansatz , which significantly reduces circuit complexity without sacrificing the fidelity of the results. This characteristic demonstrates the potential of the CHC Ansatz for scalable quantum chemistry applications, particularly in the Noisy Intermediate-Scale Quantum (NISQ) era. Furthermore, we employ the CHC Ansatz in conjunction with the Variational Quantum Deflation (VQD) algorithm to determine the excited vibrational state energies, which is compared against the reliable method of quantum Equation of Motion(qEOM). Through this comparative study, we aim to provide valuable insights into the practical applications of these Ansatz in quantum simulations of molecular systems, highlighting their respective advantages and potential for future quantum chemistry research.
Abstract We present a quantum chemistry benchmark for noisy intermediate-scale quantum computers that leverages the variational quantum eigensolver, active-space reduction, a reduced unitary coupled cluster ansatz, and reduced density purification as error mitigation. We demonstrate this benchmark using 4 of the available qubits on the 20-qubit IBM Tokyo and 16-qubit Rigetti Aspen processors via the simulation of alkali metal hydrides (NaH, KH, RbH), with accuracy of the computed ground state energy serving as the primary benchmark metric. We further parameterize this benchmark suite on the trial circuit type, the level of symmetry reduction, and error mitigation strategies. Our results demonstrate the characteristically high noise level present in near-term superconducting hardware, but provide a relevant baseline for future improvement of the underlying hardware, and a means for comparison across near-term hardware types. We also demonstrate how to reduce the noise in post processing with specific error mitigation techniques. Particularly, the adaptation of McWeeny purification of noisy density matrices dramatically improves accuracy of quantum computations, which, along with adjustable active space, significantly extends the range of accessible molecular systems. We demonstrate that for specific benchmark settings and a selected range of problems, the accuracy metric can reach chemical accuracy when computing over the cloud on certain quantum computers.
While numerical simulations are presented in most papers introducing new methods to enhance the VQE performance, comprehensive, comparative, and applied studies remain relatively rare. We present a comprehensive, yet concise guide for the implementation of the VQE for molecular problems on NISQ devices, specifically applied to estimate the ground state energy of the BeH2 molecule using hardware-efficient and chemically informed ansätze. This work clarifies several under-documented aspects in the literature, such as the construction of the electronic Hamiltonian, the transformation of fermionic operators into qubit operators via second quantization, and the mathematical framework's details for the unitary coupled cluster single and double (UCCSD) ansatz. Our methodology, implemented using Qiskit 1.2, the latest release as of the date of this writing, is demonstrated on a noiseless simulator and further tested with noisy quantum circuits. The resilience of the VQE to quantum noise remains an open question. This study compares the computational accuracy of ground state energy estimations for molecules using the VQE across three different current quantum hardware noise models. Furthermore, our experiment on IBM's 156-qubit actual quantum computer revealed valuable insights on the real performance of the VQE on current quantum hardware.
As a hybrid quantum-classical algorithm, the variational quantum eigensolver is widely applied in quantum chemistry simulations, especially in computing the electronic structure of complex molecular systems. However, on existing noisy intermediate-scale quantum devices, some factors such as quantum decoherence, measurement errors, and gate operation imprecisions are unavoidable. To overcome these challenges, this study proposes an efficient noise-mitigating variational quantum eigensolver for accurate computation of molecular ground state energies in noisy environments. We design the quantum circuit with reference to the structure of matrix product states and utilize it to pre-train the circuit parameters, which ensures circuit stability and mitigates fluctuations caused by initialization. We also employ zero-noise extrapolation to mitigate quantum noise and combine it with neural networks to improve the accuracy of the noise-fitting function, which significantly eliminates noise interference. Furthermore, we implement an intelligent grouping strategy for measuring Hamiltonian Pauli strings, which not only reduces measurement errors but also improves sampling efficiency. We perform numerical simulations to solve the ground state energy of the H4molecule by using MindSpore Quantum framework, and the results demonstrate that our algorithm can constrain noise errors within the range of O(10−2)∼O(10−1), outperforming mainstream variational quantum eigensolvers. This work provides a new strategy for high-precision quantum chemistry calculations on near-term noisy quantum hardware.