Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Absolute Sensors for gravity measurements - Cold Atom gravimeter and Gravity Gradiometer -

Almazbek Imanaliev, Romain Karcher, Romain Caldani, Mehdi Langlois, Azer Trimeche, Carlos L. Garrido Alzar, Sébastien Merlet, Franck Pereira dos Santos

Published Sep 12, 2017• 0 citations
OpenAlex

Related papers

Highly sensitive cold-atom gravity gradiometer

Xiangmin Wu, Tianteng Ma, Mingqi Huang +7 more

Physical Review Applied•Apr 16, 2026•1 citation

Cold Atom Interferometry Gravity Gradiometer: a closer look at a configuration

Franck Pereira dos Santos

•Sep 28, 2016•0 citations

High Sensitivity Gravity Measurement with Cold Atom Interferometry

Zhong-Kun Hu, Xiao‐Chun Duan, Min-Kang Zhou +1 more

We report the work of exploring atom interferometry techniques to perform precision gravity measurements in our laboratory. The noise suppressions and related modulation experiments for the atom gravimeter will be presented in detail.

•Jan 1, 2014•1 citation

Suppression of amplitude-modulation noise in dynamic atom gravimeters

Wenzhang Wang, J. F. Li, Danfang Zhang +9 more

Dynamic atom gravimeters enable absolute gravity measurements on moving platforms. However, their performance is severely degraded due to the complex dynamic environment. This paper finds that the amplitude-modulation noise (AMN) is a key factor contributing to the degradation of gravity- measurement performance. We find that the AMN is induced by the cold atomic cloud trajectory and velocity variation. We build a model to illustrate the principles and magnitude of AMN arising from various experiment processes. Then we propose a method to fit the normalized AMN with respect to the kinematic parameters of the cold atomic cloud and successfully suppress this noise from 0.11 to 0.038 using the fitting result. With this method, we improve the fringe phase resolution from 0.244 to 0.092 rad and reduce the dynamic gravity-measurement noise from 2.69 to 1.68 mGal. This study finds and suppresses a key noise source in dynamic atom gravimeters, which is useful for further improving their precision. The proposed method can also be applied for precision enhancement for other dynamic atom-interferometer-based sensors, such as atom gradiometers and gyroscopes.

Physical Review Applied•May 29, 2026•0 citations

Atom-chip-based quantum gravimetry for the precise determination of absolute gravity

Sven Abend, Christian Schubert, Wolfgang A. Ertmer +1 more

EGUGA•Apr 1, 2017•0 citations

Compact High-Flux Cold Atom Source via Single-Laser Electro-Optic Modulation for Absolute Quantum Gravimeter

Aishik Acharya, Anju, Harish Kumar Rathode

URSI General Assembly and Scientific Symposium•Jan 1, 2026•0 citations
Dynamic atom gravimeters enable absolute gravity measurements on moving platforms. However, their performance is severely degraded due to the complex dynamic environment. This paper finds that the amplitude-modulation noise (AMN) is a key factor contributing to the degradation of gravity- measurement performance. We find that the AMN is induced by the cold atomic cloud trajectory and velocity variation. We build a model to illustrate the principles and magnitude of AMN arising from various experiment processes. Then we propose a method to fit the normalized AMN with respect to the kinematic parameters of the cold atomic cloud and successfully suppress this noise from 0.11 to 0.038 using the fitting result. With this method, we improve the fringe phase resolution from 0.244 to 0.092 rad and reduce the dynamic gravity-measurement noise from 2.69 to 1.68 mGal. This study finds and suppresses a key noise source in dynamic atom gravimeters, which is useful for further improving their precision. The proposed method can also be applied for precision enhancement for other dynamic atom-interferometer-based sensors, such as atom gradiometers and gyroscopes.