Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Coherence of an Interacting Ultra-Cold Atomic Ensemble in a Trapped Matter-Wave Sensor

Alexis Bonnin, Xavier Alauze, Cyrille Solaro, Frédéric Combes, Jean-Noël Fuchs, Frédéric Piéchon, Franck Pereira dos Santos

Published Jul 17, 2017• 0 citations
OpenAlex

Related papers

Matter-wave lensing of ultracold atomic gases by interaction quenching via two-photon scattering

Meung Ho Seo, Jongchul Mun, Sang-Bum Lee +1 more

Precision quantum sensors using cold atom interferometers with long interrogation times are often limited by the ballistic expansion of atomic samples after release from traps, manifesting by means of laser beam wavefront uncertainties. In this study we utilize near-resonant light interacting with an ultracold atomic sample for collective-mode excitation of a 87Rb Bose Einstein condensate (BEC) in a magnetic trap. The collective motion is initiated after abruptly modifying the atom-atom interaction energy by reduction of the BEC atom number density via photon scattering using the two-photon transition from $5S_{1/2}$ to $5D_{5/2}$ . We show that the two-photon transition can induce matter-wave lensing of the atomic cloud with minimal center-of-mass perturbation providing an optimal ultra-cold atomic sample for atom-based quantum sensors such as quantum gravimeters and accelerometers.

EPJ Quantum Technology•Jan 27, 2025•1 citation

Towards a Cold-Atom Matter-Wave Interferometer

Peter Hannaford, Russell McLean, G. I. Opat +2 more

Springer proceedings in physics•Jan 1, 1994•1 citation

All-optical matter-wave lens using time-averaged potentials

Henning Albers, Robin Corgier, Alexander Herbst +11 more

Abstract The stability of matter-wave sensors benefits from interrogating large-particle-number atomic ensembles at high cycle rates. The use of quantum-degenerate gases with their low effective temperatures allows constraining systematic errors towards highest accuracy, but their production by evaporative cooling is costly with regard to both atom number and cycle rate. In this work, we report on the creation of cold matter-waves using a crossed optical dipole trap and shaping it by means of an all-optical matter-wave lens. We demonstrate the trade off between residual kinetic energy and atom number by short-cutting evaporative cooling and estimate the corresponding performance gain in matter-wave sensors. Our method is implemented using time-averaged optical potentials and hence easily applicable in optical dipole trapping setups.

arXiv:2109.08608•Communications Physics•Mar 16, 2022•18 citations

Coherence of cold atoms trapped by partially coherent light

Delong Kong, Mengdi Luo, Zhaoying Wang +1 more

Optics Communications•Oct 31, 2018•4 citations

Versatile optical potentials and their applications in atom interferometry

Knut Stolzenberg

Inertial navigation systems are vital for modern society, be it on airplanes or in the context of autonomous mobility. On the other hand atom interferometers are exquisite measurement devices for inertia in fundamental physics and field applications, but are mostly limited to measuring one inertial observable. By utilizing time averaged optical potentials, the ultra-cold atomic ensemble input to the interferometer can be prepared in nearly arbitrary fashion. This results in a boost of preparation speed and number of atoms in the interferometer by increasing the size of the trap to match the size of the pre-cooled ensemble for optimal loading. Successive fast reduction of the extend of the trap leads to optimal evaporation efficiency and leads to increased sensitivity of the device, due to reduced cycle time of the experiment and increased atom number. Beyond this, the technique allows for new sensor geometries via the creation of multiple single wells, allowing for differential atom interferometry with numerous simultaneous interferometers. In this thesis, the first matter-wave analogue of a classical accelerometer array is implemented via the creation of a 3 × 3 array of Bose-Einstein condensates, consisting of 3 × 105 atoms and spanning a total area of 1.6 mm2 . Successive manipulation of the matter-waves with atom optics, coherently addressing the momentum states of the ensembles, allows for splitting, redirecting and readout pulses, realizing Mach-Zehnder type atom interferometers. Correlation of the nine 1D-acceleration measurements output by the interferometers yields measurements of linear acceleration, Euler- and centrifugal acceleration. The estimated sensitivity limits per shot are 6 × 10−5m s−2 for linear acceleration, 0.19 rad s − 2 for rotational acceleration and 203 mrad s−1 for rotation rate and are mainly limited due to the short free fall time of the ensembles, constrained by the atom optics light field. The correlation also allowed to determine the rotation center, being close to the retro reflection mirror of the atom optics light field. Crucial for the realization of this measurement was the implementation of time averaged potentials as stated above, facilitated through two 2D acousto-optical deflectors and a software defined radio, allowing for generating the required RF-signals. The techniques to simultaneously load and evaporate multiple ensembles into distinct traps from a single cloud of cold atoms and subsequently enlarge the spacing between the ensembles with adiabatic transport ramps are of highest interest for e.g. the Very Long Baseline Atom Interferometer facility in Hannover. Due to the correlated outputs systematic errors, such as wave front abberations, can be nullified. Furthermore the scheme can be extended to 3D matter-wave arrays, fulfilling all requirements necessary for an autonomous inertial measurement unit.

•Jan 1, 2026•0 citations

Coherence time of a cold atomic ensemble as a quantum memory

C. W. Chou, D. Felinto, Hugues de Riedmatten +2 more

Bulletin of the American Physical Society•May 19, 2005•0 citations
Precision quantum sensors using cold atom interferometers with long interrogation times are often limited by the ballistic expansion of atomic samples after release from traps, manifesting by means of laser beam wavefront uncertainties. In this study we utilize near-resonant light interacting with an ultracold atomic sample for collective-mode excitation of a 87Rb Bose Einstein condensate (BEC) in a magnetic trap. The collective motion is initiated after abruptly modifying the atom-atom interaction energy by reduction of the BEC atom number density via photon scattering using the two-photon transition from 5S1/25S_{1/2}5S1/2​ to 5D5/25D_{5/2}5D5/2​ . We show that the two-photon transition can induce matter-wave lensing of the atomic cloud with minimal center-of-mass perturbation providing an optimal ultra-cold atomic sample for atom-based quantum sensors such as quantum gravimeters and accelerometers.
Abstract The stability of matter-wave sensors benefits from interrogating large-particle-number atomic ensembles at high cycle rates. The use of quantum-degenerate gases with their low effective temperatures allows constraining systematic errors towards highest accuracy, but their production by evaporative cooling is costly with regard to both atom number and cycle rate. In this work, we report on the creation of cold matter-waves using a crossed optical dipole trap and shaping it by means of an all-optical matter-wave lens. We demonstrate the trade off between residual kinetic energy and atom number by short-cutting evaporative cooling and estimate the corresponding performance gain in matter-wave sensors. Our method is implemented using time-averaged optical potentials and hence easily applicable in optical dipole trapping setups.
Inertial navigation systems are vital for modern society, be it on airplanes or in the context of autonomous mobility. On the other hand atom interferometers are exquisite measurement devices for inertia in fundamental physics and field applications, but are mostly limited to measuring one inertial observable. By utilizing time averaged optical potentials, the ultra-cold atomic ensemble input to the interferometer can be prepared in nearly arbitrary fashion. This results in a boost of preparation speed and number of atoms in the interferometer by increasing the size of the trap to match the size of the pre-cooled ensemble for optimal loading. Successive fast reduction of the extend of the trap leads to optimal evaporation efficiency and leads to increased sensitivity of the device, due to reduced cycle time of the experiment and increased atom number. Beyond this, the technique allows for new sensor geometries via the creation of multiple single wells, allowing for differential atom interferometry with numerous simultaneous interferometers. In this thesis, the first matter-wave analogue of a classical accelerometer array is implemented via the creation of a 3 × 3 array of Bose-Einstein condensates, consisting of 3 × 105 atoms and spanning a total area of 1.6 mm2 . Successive manipulation of the matter-waves with atom optics, coherently addressing the momentum states of the ensembles, allows for splitting, redirecting and readout pulses, realizing Mach-Zehnder type atom interferometers. Correlation of the nine 1D-acceleration measurements output by the interferometers yields measurements of linear acceleration, Euler- and centrifugal acceleration. The estimated sensitivity limits per shot are 6 × 10−5m s−2 for linear acceleration, 0.19 rad s − 2 for rotational acceleration and 203 mrad s−1 for rotation rate and are mainly limited due to the short free fall time of the ensembles, constrained by the atom optics light field. The correlation also allowed to determine the rotation center, being close to the retro reflection mirror of the atom optics light field. Crucial for the realization of this measurement was the implementation of time averaged potentials as stated above, facilitated through two 2D acousto-optical deflectors and a software defined radio, allowing for generating the required RF-signals. The techniques to simultaneously load and evaporate multiple ensembles into distinct traps from a single cloud of cold atoms and subsequently enlarge the spacing between the ensembles with adiabatic transport ramps are of highest interest for e.g. the Very Long Baseline Atom Interferometer facility in Hannover. Due to the correlated outputs systematic errors, such as wave front abberations, can be nullified. Furthermore the scheme can be extended to 3D matter-wave arrays, fulfilling all requirements necessary for an autonomous inertial measurement unit.