Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Wireless and Optical Communications Conference

Rydberg Atomic Sensor Sensitivity Optimization Using Detuned Microwave Field

Shanchi Wu, Gong Chen, Shangbin Li, Rui Ni, Jingkang Zhu

Published Aug 11, 2022• 3 citations
Publisher

Abstract

High sensitivity detection of microwave signals is important for communication systems. The sensitivity of Rydberg atomic sensors at the standard quantum limit has great advantages over conventional systems, but the actual experimental systems has not reached such level yet. We provide an optimization method to improve the sensitivity of Rydberg atomic sensors based on the four-level model based on frequency detuning. It was numerically demonstrated that both the microwave field detuning and laser power settings can improve the sensitivity of the system.

DOI
10.1109/wocc55104.2022.9880581

Related papers

Sensitivity Improvement and Determination of Rydberg Atom-Based Microwave Sensor

Minghao Cai, Zi-Shan Xu, Shuhang You +1 more

We present a theoretical and experimental investigation of the improvement and determination of the sensitivity of Rydberg atom-based microwave RF sensor. An optical Bloch equation has been set up based on the configuration that two-color cascading lasers exciting atom to highly Rydberg state and a microwave RF coupling this Rydberg state to its adjacent neighbor. The numerical simulation shows that the sensitivity of the atomic RF sensor is correlated with the amplitude strengths of the applied two lasers and the RF itself. It also depends on the frequency detuning of the coupling laser, which induces an asymmetrically optical splitting. The coupling laser frequency fixing at the shoulder of the stronger one is more favorable for a higher sensitivity. Accordingly, we perform an experimental demonstration for the optimization of all these parameters and the sensitivity is improved to 12.50(04) nVcm−1·Hz−1/2.

Photonics•Apr 10, 2022•75 citations

Theoretical Analysis of Heterodyne Rydberg Atomic Receiver Sensitivity Based on Transit Relaxation Effect and Frequency Detuning

Shanchi Wu, Chen Gong, Shangbin Li +2 more

We conduct a theoretical investigation into the impacts of local microwave electric field frequency detuning, laser frequency detuning, and transit relaxation rate on enhancing heterodyne Rydberg atomic receiver sensitivity. To optimize the output signal amplitude given the input microwave signal, we derive the steady-state solutions of the atomic density matrix. Numerical results show that laser frequency detuning and local microwave electric field frequency detuning can improve the system detection sensitivity, which can help the system achieve extra sensitivity gain. It also shows that the heterodyne Rydberg atomic receiver can detect weak microwave signals continuously over a wide frequency range with the same sensitivity or even more sensitivity than the resonance case. To evaluate the transit relaxation effect, a modified Liouville equation is used. We find that the transition relaxation rate increases the time it takes to reach steady state and decreases the sensitivity of the system detection.

arXiv:2306.17790•Jun 30, 2023•1 citation

High-Sensitivity Rydberg Atom-Based Field Sensing Enhancement Using Miniaturized Resonator

Aojie Zhou, Yi Lin, Ruiqi Mao +4 more

High-sensitivity amplitude and frequency detection of microwave electric fields is of significant importance in various fields, including communications, microwave quantum technology, aerospace, medicine, and meteorology. Rydberg atom-based sensors promise traceable standards and high sensitivity for detecting weak electric fields and enhancing sensing sensitivity, mainly by using superheterodyne technology and resonant structures. Detecting high-frequency (HF) band fields with high sensitivity using Rydberg atom sensors is a significant challenge due to the requirement of exciting atoms to extremely high energy states for resonant detection. We demonstrate the off-resonant Rydberg atomic superheterodyne architecture with additional resonators for greatly enhancing the sensing sensitivity to HF band fields. In this approach, we propose a miniaturized square spiral resonator with an electrical size of$0.011~\lambda $at 15.54 MHz. To reduce the electric-field-screening effect of the adsorption of alkali metal atoms, we use a monocrystalline sapphire cesium (Cs) vapor cell. By utilizing the off-resonant alternating current (ac) Stark effect, the initial sensitivity of the Rydberg atom sensor without the resonator is measured to be$10.39~\mu \text {V/cm}\sqrt {\text {Hz}}$at room temperature. With the addition of the miniaturized square spiral resonator, the sensitivity significantly improved to$2.60~\text {nV/cm}\sqrt {\text {Hz}}$, which has been inaccessible so far with atomic sensors. Here, we provide an enhancement of 72 dB, which is three orders of magnitude improvement in sensitivity than when the resonator is not used. This enhancement resonator extends Rydberg atomic high-sensitivity sensing to the HF band and shows great potential, especially in shortwave radio reception.

IEEE Transactions on Antennas and Propagation•Aug 13, 2025•9 citations

Enhanced sensing of 3.4 GHz microwave in multi-level Rydberg atomic system

Jingjing XUE, Ruonan LI, Hu Xuesong +3 more

The Rydberg-based microwave detection is an all-optical technology that uses the strong coherent interaction between Rydberg atoms and microwave field. Different from the traditional microwave meter, the Rydberg atomic sensing is a new-type microwave detector that transforms the microwave spectrum into a coherent optical spectrum, and arouses increasingly the interests due to its high sensibility. For this kind of sensor, the coherence effect induced by coupling atoms with microwave plays a key role, and the decoherence may reduce the sensitivity. A multi-level Rydberg atomic scheme with optimized quantum coherence, which enhances both the bandwidth and the sensitivity for 4 GHz microwave sensing, is demonstrated experimentally in this work. The enhanced quantum coherence of Rydberg electromagnetically induced transparency (EIT) and microwave induced Autler-Townes (AT) splitting in EIT windows are shown using optical pumping at D1 line. The enhanced sensitivity at 3.4 GHz with 0.3 GHz bandwidth can be realized, based on the enhanced EIT-AT spectrum. The experimental results show that in the stepped Rydberg EIT system, the spectral width of EIT and microwave field EIT-AT can be narrowed by optical pumping (OP), so the sensitivity of microwave electric field measurement can be improved. After optimizing the EIT amplitude and adding single-frequency microwaves, the sensitivity of the microwave electric field measurement observed by the AT splitting interval is improved by 1.3 times. This work provides a reference for utilizing atomic microwave detection.

Acta Physica Sinica•Jan 1, 2025•1 citation

Enhanced sensing of 3.4 GHz microwave in multi-level Rydberg atomic system

Jingjing, Xue, Ruonan, Li, Hu Xuesong +3 more

The Rydberg-based microwave detection is an all-optical technology that uses the strong coherent interaction between Rydberg atoms and microwave field. Different from the traditional microwave meter, the Rydberg atomic sensing is a new-type microwave detector that transforms the microwave spectrum into a coherent optical spectrum, and arouses increasingly the interests due to its high sensibility. For this kind of sensor, the coherence effect induced by coupling atoms with microwave plays a key role, and the decoherence may reduce the sensitivity. A multi-level Rydberg atomic scheme with optimized quantum coherence, which enhances both the bandwidth and the sensitivity for 4 GHz microwave sensing, is demonstrated experimentally in this work. The enhanced quantum coherence of Rydberg electromagnetically induced transparency (EIT) and microwave induced Autler-Townes (AT) splitting in EIT windows are shown using optical pumping at D1 line. The enhanced sensitivity at 3.4 GHz with 0.3 GHz bandwidth can be realized, based on the enhanced EIT-AT spectrum. The experimental results show that in the stepped Rydberg EIT system, the spectral width of EIT and microwave field EIT-AT can be narrowed by optical pumping (OP), so the sensitivity of microwave electric field measurement can be improved. After optimizing the EIT amplitude and adding single-frequency microwaves, the sensitivity of the microwave electric field measurement observed by the AT splitting interval is improved by 1.3 times. This work provides a reference for utilizing atomic microwave detection.

arXiv:2508.01260•Aug 2, 2025•0 citations

Sensitivity enhancement in Rydberg atomic microwave superheterodyne measurements through laser-atom-microwave interaction mechanisms

Zhongzhou Tian, Guojin Zeng, Chao Yan +3 more

Measurement sensitivity is crucial for the practical application of Rydberg atomic microwave superheterodyne receiver systems in communication, radar, and navigation. Based on laser-atom-microwave interaction mechanisms, the influence of laser powers and local-oscillator (LO) microwave field intensity on measurement sensitivity is systematically studied in this paper. Measurement sensitivity is analyzed through electromagnetically induced transparency (EIT) spectral characteristics, specifically EIT amplitude and full-width-half-maximum (FWHM),larger amplitudes and narrower FWHM indicate improved signal-to-noise ratios. For a 60D-state Rydberg atomic system with fixed probe and coupling laser beam waists (800 µm and 875 µm), optimal parameters are determined: probe laser power of 60 µW(Rabi frequency: 2π×7.02 MHz), coupling laser power of 40 mW (Rabi frequency: 2π×0.66 MHz), and LO microwave Rabi frequency of 2π×8.34 MHz. Experimental results demonstrate a 4.6 dB sensitivity enhancement, advancing from −137.5dBm/Hz to −142.1 dBm/Hz at 3.21 GHz microwave field. This improvement is attributed to precise alignment of laser-atom and microwave-atom interactions, bridging the gap toward quantum sensitivity limits.

Applied Optics and Photonics China (AOPC)•Oct 28, 2025•0 citations
High sensitivity detection of microwave signals is important for communication systems. The sensitivity of Rydberg atomic sensors at the standard quantum limit has great advantages over conventional systems, but the actual experimental systems has not reached such level yet. We provide an optimization method to improve the sensitivity of Rydberg atomic sensors based on the four-level model based on frequency detuning. It was numerically demonstrated that both the microwave field detuning and laser power settings can improve the sensitivity of the system.
We present a theoretical and experimental investigation of the improvement and determination of the sensitivity of Rydberg atom-based microwave RF sensor. An optical Bloch equation has been set up based on the configuration that two-color cascading lasers exciting atom to highly Rydberg state and a microwave RF coupling this Rydberg state to its adjacent neighbor. The numerical simulation shows that the sensitivity of the atomic RF sensor is correlated with the amplitude strengths of the applied two lasers and the RF itself. It also depends on the frequency detuning of the coupling laser, which induces an asymmetrically optical splitting. The coupling laser frequency fixing at the shoulder of the stronger one is more favorable for a higher sensitivity. Accordingly, we perform an experimental demonstration for the optimization of all these parameters and the sensitivity is improved to 12.50(04) nVcm−1·Hz−1/2.
We conduct a theoretical investigation into the impacts of local microwave electric field frequency detuning, laser frequency detuning, and transit relaxation rate on enhancing heterodyne Rydberg atomic receiver sensitivity. To optimize the output signal amplitude given the input microwave signal, we derive the steady-state solutions of the atomic density matrix. Numerical results show that laser frequency detuning and local microwave electric field frequency detuning can improve the system detection sensitivity, which can help the system achieve extra sensitivity gain. It also shows that the heterodyne Rydberg atomic receiver can detect weak microwave signals continuously over a wide frequency range with the same sensitivity or even more sensitivity than the resonance case. To evaluate the transit relaxation effect, a modified Liouville equation is used. We find that the transition relaxation rate increases the time it takes to reach steady state and decreases the sensitivity of the system detection.
High-sensitivity amplitude and frequency detection of microwave electric fields is of significant importance in various fields, including communications, microwave quantum technology, aerospace, medicine, and meteorology. Rydberg atom-based sensors promise traceable standards and high sensitivity for detecting weak electric fields and enhancing sensing sensitivity, mainly by using superheterodyne technology and resonant structures. Detecting high-frequency (HF) band fields with high sensitivity using Rydberg atom sensors is a significant challenge due to the requirement of exciting atoms to extremely high energy states for resonant detection. We demonstrate the off-resonant Rydberg atomic superheterodyne architecture with additional resonators for greatly enhancing the sensing sensitivity to HF band fields. In this approach, we propose a miniaturized square spiral resonator with an electrical size of$0.011~\lambda $at 15.54 MHz. To reduce the electric-field-screening effect of the adsorption of alkali metal atoms, we use a monocrystalline sapphire cesium (Cs) vapor cell. By utilizing the off-resonant alternating current (ac) Stark effect, the initial sensitivity of the Rydberg atom sensor without the resonator is measured to be10.39 μV/cmHz10.39~\mu \text {V/cm}\sqrt {\text {Hz}}10.39 μV/cmHz​at room temperature. With the addition of the miniaturized square spiral resonator, the sensitivity significantly improved to2.60 nV/cmHz2.60~\text {nV/cm}\sqrt {\text {Hz}}2.60 nV/cmHz​, which has been inaccessible so far with atomic sensors. Here, we provide an enhancement of 72 dB, which is three orders of magnitude improvement in sensitivity than when the resonator is not used. This enhancement resonator extends Rydberg atomic high-sensitivity sensing to the HF band and shows great potential, especially in shortwave radio reception.
The Rydberg-based microwave detection is an all-optical technology that uses the strong coherent interaction between Rydberg atoms and microwave field. Different from the traditional microwave meter, the Rydberg atomic sensing is a new-type microwave detector that transforms the microwave spectrum into a coherent optical spectrum, and arouses increasingly the interests due to its high sensibility. For this kind of sensor, the coherence effect induced by coupling atoms with microwave plays a key role, and the decoherence may reduce the sensitivity. A multi-level Rydberg atomic scheme with optimized quantum coherence, which enhances both the bandwidth and the sensitivity for 4 GHz microwave sensing, is demonstrated experimentally in this work. The enhanced quantum coherence of Rydberg electromagnetically induced transparency (EIT) and microwave induced Autler-Townes (AT) splitting in EIT windows are shown using optical pumping at D1 line. The enhanced sensitivity at 3.4 GHz with 0.3 GHz bandwidth can be realized, based on the enhanced EIT-AT spectrum. The experimental results show that in the stepped Rydberg EIT system, the spectral width of EIT and microwave field EIT-AT can be narrowed by optical pumping (OP), so the sensitivity of microwave electric field measurement can be improved. After optimizing the EIT amplitude and adding single-frequency microwaves, the sensitivity of the microwave electric field measurement observed by the AT splitting interval is improved by 1.3 times. This work provides a reference for utilizing atomic microwave detection.
The Rydberg-based microwave detection is an all-optical technology that uses the strong coherent interaction between Rydberg atoms and microwave field. Different from the traditional microwave meter, the Rydberg atomic sensing is a new-type microwave detector that transforms the microwave spectrum into a coherent optical spectrum, and arouses increasingly the interests due to its high sensibility. For this kind of sensor, the coherence effect induced by coupling atoms with microwave plays a key role, and the decoherence may reduce the sensitivity. A multi-level Rydberg atomic scheme with optimized quantum coherence, which enhances both the bandwidth and the sensitivity for 4 GHz microwave sensing, is demonstrated experimentally in this work. The enhanced quantum coherence of Rydberg electromagnetically induced transparency (EIT) and microwave induced Autler-Townes (AT) splitting in EIT windows are shown using optical pumping at D1 line. The enhanced sensitivity at 3.4 GHz with 0.3 GHz bandwidth can be realized, based on the enhanced EIT-AT spectrum. The experimental results show that in the stepped Rydberg EIT system, the spectral width of EIT and microwave field EIT-AT can be narrowed by optical pumping (OP), so the sensitivity of microwave electric field measurement can be improved. After optimizing the EIT amplitude and adding single-frequency microwaves, the sensitivity of the microwave electric field measurement observed by the AT splitting interval is improved by 1.3 times. This work provides a reference for utilizing atomic microwave detection.
Measurement sensitivity is crucial for the practical application of Rydberg atomic microwave superheterodyne receiver systems in communication, radar, and navigation. Based on laser-atom-microwave interaction mechanisms, the influence of laser powers and local-oscillator (LO) microwave field intensity on measurement sensitivity is systematically studied in this paper. Measurement sensitivity is analyzed through electromagnetically induced transparency (EIT) spectral characteristics, specifically EIT amplitude and full-width-half-maximum (FWHM),larger amplitudes and narrower FWHM indicate improved signal-to-noise ratios. For a 60D-state Rydberg atomic system with fixed probe and coupling laser beam waists (800 µm and 875 µm), optimal parameters are determined: probe laser power of 60 µW(Rabi frequency: 2π×7.02 MHz), coupling laser power of 40 mW (Rabi frequency: 2π×0.66 MHz), and LO microwave Rabi frequency of 2π×8.34 MHz. Experimental results demonstrate a 4.6 dB sensitivity enhancement, advancing from −137.5dBm/Hz to −142.1 dBm/Hz at 3.21 GHz microwave field. This improvement is attributed to precise alignment of laser-atom and microwave-atom interactions, bridging the gap toward quantum sensitivity limits.