Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Low Temperature Physics

Investigation of Ti/Au Transition-Edge Sensors for Single-Photon Detection

Xiaolong Xu, M. Rajteri, Jinjin Li, Shuo Zhang, Carlo Pepe, Jian Chen, Huifang Gao, Qi Li, Wei Li, Xu Li, Mingyu Zhang, Yanyan Ouyang, Xueshen Wang

Published Aug 16, 2022• 7 citations
Publisher
DOI
10.1007/s10909-022-02818-5

Related papers

High-Performance Ti Transition-Edge Sensor-based Photon-Number Resolving Detectors

Peizhan Li, Jiaqiang Zhong, Wen Zhang +8 more

Journal of Low Temperature Physics•Nov 23, 2023•14 citations

Single and few-photon detection using superconducting transition edge sensors

Daiji Fukuda, Takahiro Kikuchi

Progress in optics•Jan 1, 2024•7 citations

Improving Energy Detection Efficiency of Ti-Based Superconducting Transition-Edge Sensors with Optical Cavity

Y. Geng, Wen Zhang, Peng Li +7 more

Journal of Low Temperature Physics•Feb 13, 2020•13 citations

Investigation of Ti/Pd Bilayer for Single Photon Detection

E. Taralli, Chiara Portesi, Roberto Rocci +2 more

Transition-edge sensor (TES) microcalorimeters are promising for application in the field of quantum information and quantum computation thanks to their outstanding single photon detection capabilities. Good energy resolution and photon number discrimination at visible and near-infrared wavelengths make them extensively used as single photon detectors. In this work we report details on the fabrication of Pd/Ti TESs deposited by e-beam evaporation on silicon nitride substrates. We use Pd as alternative to Au layer thanks to its stronger influence on the Ti layer, that allows to obtain the same temperature reduction with thinner layers. The transition temperatures Tcof the devices range from 83 to 110 mK with a transition width DeltaTc=0.5 mK. Thermal and electric characteristics of Pd/Ti TESs at different temperatures and its capability as single photon sensor are reported.

IEEE Transactions on Applied Superconductivity•Jun 1, 2009•16 citations

Characterization and fabrication of Ti/Pd bilayers for transition-edge sensors

E. Monticone, E. Taralli, Chiara Portesi +4 more

Transition-edge sensor (TES) microcalorimeters are extensively used as single photon detectors from infrared to x-ray. Their good energy resolution and photon number resolving capability at visible and near-infrared wavelengths make them powerful tools for quantum information and quantum computation. In this work we report details on the fabrication of Ti/Pd TESs deposited by e-beam evaporation on silicon nitride substrates. By the proximity effect between Ti and Pd, the Ti critical temperature was tuned down to 100 mK, usual working temperature for these devices. Sharp transition of two-three mK and reproducible Tc were obtained. The Pd material can be a valid alternative to widely used Au proximity material thanks to its stronger influence on the Ti layer, that allows to obtain the same temperature reduction with thinner layers. Thermal and electrical characteristics of Ti/Au and Ti/Pd bilayers are compared in view of single photon detection.

Journal of Physics Conference Series•Mar 1, 2009•1 citation

Research Progress of Superconducting Transition-Edge Sensor Based Single-Photon Detector

朝阳 王

Applied Physics•Jan 1, 2023•0 citations
Transition-edge sensor (TES) microcalorimeters are promising for application in the field of quantum information and quantum computation thanks to their outstanding single photon detection capabilities. Good energy resolution and photon number discrimination at visible and near-infrared wavelengths make them extensively used as single photon detectors. In this work we report details on the fabrication of Pd/Ti TESs deposited by e-beam evaporation on silicon nitride substrates. We use Pd as alternative to Au layer thanks to its stronger influence on the Ti layer, that allows to obtain the same temperature reduction with thinner layers. The transition temperatures Tcof the devices range from 83 to 110 mK with a transition width DeltaTc=0.5 mK. Thermal and electric characteristics of Pd/Ti TESs at different temperatures and its capability as single photon sensor are reported.
Transition-edge sensor (TES) microcalorimeters are extensively used as single photon detectors from infrared to x-ray. Their good energy resolution and photon number resolving capability at visible and near-infrared wavelengths make them powerful tools for quantum information and quantum computation. In this work we report details on the fabrication of Ti/Pd TESs deposited by e-beam evaporation on silicon nitride substrates. By the proximity effect between Ti and Pd, the Ti critical temperature was tuned down to 100 mK, usual working temperature for these devices. Sharp transition of two-three mK and reproducible Tc were obtained. The Pd material can be a valid alternative to widely used Au proximity material thanks to its stronger influence on the Ti layer, that allows to obtain the same temperature reduction with thinner layers. Thermal and electrical characteristics of Ti/Au and Ti/Pd bilayers are compared in view of single photon detection.