Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SQUID magnetometers: a tool for ultrasensitive measurements embedded in a controlled network environment

Pascal Febvre, E. Pozzo di Borgo, G. Waysand, Henry, Samuel, B. Abi, A. Cottle, Coenrad Johann Fourie, Elda Saunderson, Daniel J. Gouws, Ali Bozbey, A. Cavaillou, DANIEL B. BOYER, Jean‐Baptiste Decitre

Published Jun 3, 2015• 0 citations
OpenAlex

Related papers

Magnetochemical studies with a ultrasensitive superconducting quantum magnetometer

Hans E. Hoenig, Ruoshui Wang, George R. Rossman +1 more

•Jan 1, 1972•1 citation

Measurement of the static magnetization of spin-polarized atomic hydrogen with a squid magnetometer

Jook T. M. Walraven, Isaac F. Silvera

Physica B+C•Aug 1, 1981•3 citations

Single-quadrature quantum magnetometry in cavity electromagnonics

Mehri Sadat Ebrahimi, Ali Motazedifard, M. Bagheri Harouni

A scheme of an ultrasensitive magnetometer in the cavity quantum electromagnonics is proposed, where the intracavity microwave mode is coupled to a magnonic mode via magnetic dipole interaction. It is shown that by driving both magnonic and microwave modes with external classical fields and controlling the system parameters, one can reduce the added noise of magnetic field measurement below the standard quantum limit (SQL). Surprisingly, we show that beyond the rotating wave approximation (RWA), not only can the added noise be suppressed but also the output cavity response to the input signal can be substantially amplified in order to achieve a precise magnetic-field measurement. The estimated theoretical sensitivity of the proposed magnetic amplifier-sensor is approximately on the order of ${10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}\mathrm{T}/\sqrt{\mathrm{Hz}}$, which is competitive compared to the current state-of-the-art magnetometers like superconducting quantum interference devices (SQUIDs) and atomic magnetometers. The advantages of the proposed sensor in comparison with the other magnetometers is its high sensitivity at room temperature, sensing in a wide range of frequencies up to MHz, and its capability for signal-response amplification.

arXiv:2011.06081•Physical Review A•Jun 10, 2021•52 citations

A Single-chip Squid Magnetometer

Fujimaki, Tamura, Imamura +1 more

Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference•Jan 1, 1988•14 citations

Static and Microwave Transport Properties of Aluminum Nanobridge Josephson Junctions

Eli M. Levenson-Falk

Josephson junctions are the basis of superconducting qubits, amplifiers, and magnetometers. Historically, tunnel-style junctions have been most common. However, for some applications--those requiring a small, highly transparent, all-superconducting junction--nanobridge weak link junctions may be preferable. This thesis presents extensive characterization of aluminum nanobridge Josephson junctions. The junction behavior is simulated by numerically solving the Usadel equations. These simulations are then tested and confirmed via low- and microwave-frequency transport measurements. The data confirm that nanobridge junctions approach the ideal weak-link Josephson limit.Such a near-ideal junction can be used in a superconducting quantum interference device (SQUID) to form an ultra sensitive magnetometer. This thesis presents the first nanobridge-based dispersive SQUID magnetometer. The devices show near-zero dissipation, with bandwidth and sensitivity on par with the best reported results for any SQUID-based magnetometer. These magnetometers have several flexible modes of operation, allowing for optimization of sensitivity, bandwidth, or backaction. They also provide insight into the internal dynamics of dispersive measurement with nonlinear cavities, as the magnetometer backaction depends on the bias point and can readily be measured.Nanobridge junctions also provide a useful tool for diagnosing sources of decoherence in superconducting qubits. By replacing the usual tunnel junction with a nanobridge, the contribution of the junction to decoherence processes may be probed. In particular, the interaction of nanobridge junctions with quasiparticles provides information both about the junctions themselves and about quasiparticle generation and relaxation mechanisms. This thesis reports measurements of nonequilibrium quasiparticles trapping in phase-biased nanobridge junctions. By probing the quasiparticle-induced changes in resonant frequency of a high-Q nanoSQUID oscillator, one may measure the mean distribution of trapped quasiparticles and study its temperature dependence. These measurements also provide spectroscopy of the junctions' internal Andreev states and the dynamics of quasiparticle excitation and retrapping. The work presented here demonstrates the utility of nanobridge junctions as a tool for quantifying the population and distribution of quasiparticles in a superconducting circuit.

•Jan 1, 2013•1 citation

Multi-channel DC-SQUID magnetometer project

Jakob Flokstra, A. Martínez, Evert Pieter Houwman +4 more

•Jan 1, 1990•0 citations
A scheme of an ultrasensitive magnetometer in the cavity quantum electromagnonics is proposed, where the intracavity microwave mode is coupled to a magnonic mode via magnetic dipole interaction. It is shown that by driving both magnonic and microwave modes with external classical fields and controlling the system parameters, one can reduce the added noise of magnetic field measurement below the standard quantum limit (SQL). Surprisingly, we show that beyond the rotating wave approximation (RWA), not only can the added noise be suppressed but also the output cavity response to the input signal can be substantially amplified in order to achieve a precise magnetic-field measurement. The estimated theoretical sensitivity of the proposed magnetic amplifier-sensor is approximately on the order of ${10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}\mathrm{T}/\sqrt{\mathrm{Hz}}$, which is competitive compared to the current state-of-the-art magnetometers like superconducting quantum interference devices (SQUIDs) and atomic magnetometers. The advantages of the proposed sensor in comparison with the other magnetometers is its high sensitivity at room temperature, sensing in a wide range of frequencies up to MHz, and its capability for signal-response amplification.
Josephson junctions are the basis of superconducting qubits, amplifiers, and magnetometers. Historically, tunnel-style junctions have been most common. However, for some applications--those requiring a small, highly transparent, all-superconducting junction--nanobridge weak link junctions may be preferable. This thesis presents extensive characterization of aluminum nanobridge Josephson junctions. The junction behavior is simulated by numerically solving the Usadel equations. These simulations are then tested and confirmed via low- and microwave-frequency transport measurements. The data confirm that nanobridge junctions approach the ideal weak-link Josephson limit.Such a near-ideal junction can be used in a superconducting quantum interference device (SQUID) to form an ultra sensitive magnetometer. This thesis presents the first nanobridge-based dispersive SQUID magnetometer. The devices show near-zero dissipation, with bandwidth and sensitivity on par with the best reported results for any SQUID-based magnetometer. These magnetometers have several flexible modes of operation, allowing for optimization of sensitivity, bandwidth, or backaction. They also provide insight into the internal dynamics of dispersive measurement with nonlinear cavities, as the magnetometer backaction depends on the bias point and can readily be measured.Nanobridge junctions also provide a useful tool for diagnosing sources of decoherence in superconducting qubits. By replacing the usual tunnel junction with a nanobridge, the contribution of the junction to decoherence processes may be probed. In particular, the interaction of nanobridge junctions with quasiparticles provides information both about the junctions themselves and about quasiparticle generation and relaxation mechanisms. This thesis reports measurements of nonequilibrium quasiparticles trapping in phase-biased nanobridge junctions. By probing the quasiparticle-induced changes in resonant frequency of a high-Q nanoSQUID oscillator, one may measure the mean distribution of trapped quasiparticles and study its temperature dependence. These measurements also provide spectroscopy of the junctions' internal Andreev states and the dynamics of quasiparticle excitation and retrapping. The work presented here demonstrates the utility of nanobridge junctions as a tool for quantifying the population and distribution of quasiparticles in a superconducting circuit.