Chinese Physics B

In situ temperature measurement of vapor based on atomic speed selection

Yu Lu, Cao Li, Ziqian Yue, Lin Li, Yueyang Zhai

Published Jul 22, 2022• 1 citation
Publisher

Abstract

We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position of the crossover peaks can move along the spectrum. Different velocity classes of atoms contribute to the crossover during the movement. We study the relationship between the intensity change of peaks and vapor temperature. Our experimental result around room temperature shows a deviation of less than 0.3 K. Compared with traditional thermometry using absorption spectroscopy, higher accuracy can theoretically be achieved with real-time thermometry.

DOI
10.1088/1674-1056/ac8341

Related papers

Measuring the Hyperfine Splittings of Lowest Energy Atomic Transitions in Rubidium

Benjamin Graber

The goal of this experiment was to measure the hyperfine energy splittings of the ground to first excited state transitions in rubidium using saturated absorption spectroscopy. Using this technique, we measured these transition energy spectra by taking the difference of two photodiode outputs due to multiple beams of a single laser scanned over a range of frequencies and shone through a cell of Rb vapor. When the laser frequency was resonant with an atomic transition, photons of those frequencies were absorbed, leaving a dip in intensity of the beam measured at the photodiode. One of the two laser beams had its excitations saturated by a more intense, counter-propagating pump beam from the same laser. The pump beam saturated the absorption of the velocity equal zero atoms that the counter-propagating probe beam could have also interacted with due to no Doppler shift. At these frequencies the probe beam experienced less absorption that was measured by a photodiode. The photodiode output was calibrated to the change in frequency of the scanned laser using a Fabry-Pérot interferometer. The output of this interferometer served as a reference for how the laser frequency changed. Final results for the 87Rb F=1 spectrum accounted for the largest error with a maximum of 12.2% deviation from accepted energy spacing values due in part to systematic error. Other spectra measurements were in better agreement, possessing error ranging from 2.1% to 10.1% and some agreeing with accepted values to within our uncertainty.

•Jan 1, 2015•0 citations

In-situ measurement of vapor cell temperature based on obliquely incident pump light for NMR sensors

Chuanming Yin, Xiangyang Zhou, Weiqian Wang +6 more

This paper presents a pump-light-based in-situ temperature measurement method for nuclear magnetic resonance (NMR) vapor cells under oblique optical incidence. To miniaturize the NMR sensor, a thin vapor cell is employed, in which both the orthogonal pump and probe light are introduced obliquely through one surface of the vapor cell. A model is developed to relate pump-light absorption to Rb atomic density, thereby enabling inference of the vapor cell temperature. The model includes polarization distortion, polarization-dependent window transmission attenuation, effective optical path length, and the coupling between optical absorption and atomic polarization. Experimental results show that the proposed method achieves the lowest RMSE of 0.179 K and reduces it by at least 68.2% compared with several commonly used fitting methods, enabling accurate in-situ temperature measurement in miniaturized NMR sensors under obliquely incident pumping.

Optics Express•Jun 4, 2026•0 citations

Fast thermometry for trapped atoms using recoil-induced resonance

Yanting Zhao, Dian-Qiang Su, Zhonghua Ji +3 more

We have employed recoil-induced resonance (RIR) with linewidth on the order of 10 kHz to demonstrate the fast thermometry for ultracold atoms. We theoretically calculate the absorption spectrum of RIR which agrees well with the experimental results. The temperature of the ultracold sample derived from the RIR spectrum is T = 84±4.5 μK, which is close to 85 μK that measured by the method of time-of-flight absorption imaging. To exhibit the fast measurement advantage in applying RIR to the ultracold atom thermometry, we study the dependence of ultracold sample temperature on the trapping beam frequency detuning. This method can be applied to determine the translational temperature of molecules in photoassociation dynamics.

Chinese Physics B•Sep 1, 2015•2 citations

Quantum-Enhanced Velocimetry with Doppler-Broadened Atomic Vapor

Zilong Chen, Hong Ming Lim, Chang Cang Huang +2 more

Traditionally, measuring the center-of-mass (c.m.) velocity of an atomic ensemble relies on measuring the Doppler shift of the absorption spectrum of single atoms in the ensemble. Mapping out the velocity distribution of the ensemble is indispensable when determining the c.m. velocity using this technique. As a result, highly sensitive measurements require preparation of an ensemble with a narrow Doppler width. Here, we use a dispersive measurement of light passing through a moving room temperature atomic vapor cell to determine the velocity of the cell in a single shot with a short-term sensitivity of 5.5 μm s^{-1} Hz^{-1/2}. The dispersion of the medium is enhanced by creating quantum interference through an auxiliary transition for the probe light under electromagnetically induced transparency condition. In contrast to measurement of single atoms, this method is based on the collective motion of atoms and can sense the c.m. velocity of an ensemble without knowing its velocity distribution. Our results improve the previous measurements by 3 orders of magnitude and can be used to design a compact motional sensor based on thermal atoms.

arXiv:2003.03491•Physical Review Letters•Mar 6, 2020•14 citations

Temperature measurement of cold atoms in a cesium magneto-optical trap by means of short-distance time-of-flight absorption spectrum

Tao Geng, 闫树斌 Yan Shubin, Yanhua Wang +4 more

We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.

Acta Physica Sinica•Jan 1, 2005•7 citations

Design of a Measuring Device and Experimental Study into the Relationship between Temperature and the Density of Alkali Metal-Vapor

Huining Shang, Sheng Zou, Wei Quan +4 more

The temperature of the alkali metal cell, which affects the density of the alkali-metal vapor and the gas pressure, is usually difficult to measure directly. However, the temperature of the alkali-metal cell and the density of the alkali-metal vapor are important parameters that affect the performance of the atomic sensor. In this paper, a device that can directly measure the internal temperature of an alkali metal cell in real time is designed for the first time to explore the relationship between alkali-metal vapor density and temperature. Alkali-metal vapor density is measured using the absorption spectrum. The pressure broadening model, combined with the transition of four hyperfine levels, was used to fit the absorption line of 87Rb D1 under the action of 700 Torr N2, and a good fitting effect was obtained. The experimental results show that the density of 87Rb is less than the value calculated by the empirical formula. Based on the experimental results, we give the calculation formula of 87Rb density with an uncertainty of only 4% and obtain the temperature dependence index of the line width and linear displacement of 87Rb in N2 by analyzing the absorption spectrum.

Photonics•Jan 21, 2023•11 citations
We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position of the crossover peaks can move along the spectrum. Different velocity classes of atoms contribute to the crossover during the movement. We study the relationship between the intensity change of peaks and vapor temperature. Our experimental result around room temperature shows a deviation of less than 0.3 K. Compared with traditional thermometry using absorption spectroscopy, higher accuracy can theoretically be achieved with real-time thermometry.
The goal of this experiment was to measure the hyperfine energy splittings of the ground to first excited state transitions in rubidium using saturated absorption spectroscopy. Using this technique, we measured these transition energy spectra by taking the difference of two photodiode outputs due to multiple beams of a single laser scanned over a range of frequencies and shone through a cell of Rb vapor. When the laser frequency was resonant with an atomic transition, photons of those frequencies were absorbed, leaving a dip in intensity of the beam measured at the photodiode. One of the two laser beams had its excitations saturated by a more intense, counter-propagating pump beam from the same laser. The pump beam saturated the absorption of the velocity equal zero atoms that the counter-propagating probe beam could have also interacted with due to no Doppler shift. At these frequencies the probe beam experienced less absorption that was measured by a photodiode. The photodiode output was calibrated to the change in frequency of the scanned laser using a Fabry-Pérot interferometer. The output of this interferometer served as a reference for how the laser frequency changed. Final results for the 87Rb F=1 spectrum accounted for the largest error with a maximum of 12.2% deviation from accepted energy spacing values due in part to systematic error. Other spectra measurements were in better agreement, possessing error ranging from 2.1% to 10.1% and some agreeing with accepted values to within our uncertainty.
This paper presents a pump-light-based in-situ temperature measurement method for nuclear magnetic resonance (NMR) vapor cells under oblique optical incidence. To miniaturize the NMR sensor, a thin vapor cell is employed, in which both the orthogonal pump and probe light are introduced obliquely through one surface of the vapor cell. A model is developed to relate pump-light absorption to Rb atomic density, thereby enabling inference of the vapor cell temperature. The model includes polarization distortion, polarization-dependent window transmission attenuation, effective optical path length, and the coupling between optical absorption and atomic polarization. Experimental results show that the proposed method achieves the lowest RMSE of 0.179 K and reduces it by at least 68.2% compared with several commonly used fitting methods, enabling accurate in-situ temperature measurement in miniaturized NMR sensors under obliquely incident pumping.
We have employed recoil-induced resonance (RIR) with linewidth on the order of 10 kHz to demonstrate the fast thermometry for ultracold atoms. We theoretically calculate the absorption spectrum of RIR which agrees well with the experimental results. The temperature of the ultracold sample derived from the RIR spectrum is T = 84±4.5 μK, which is close to 85 μK that measured by the method of time-of-flight absorption imaging. To exhibit the fast measurement advantage in applying RIR to the ultracold atom thermometry, we study the dependence of ultracold sample temperature on the trapping beam frequency detuning. This method can be applied to determine the translational temperature of molecules in photoassociation dynamics.
Traditionally, measuring the center-of-mass (c.m.) velocity of an atomic ensemble relies on measuring the Doppler shift of the absorption spectrum of single atoms in the ensemble. Mapping out the velocity distribution of the ensemble is indispensable when determining the c.m. velocity using this technique. As a result, highly sensitive measurements require preparation of an ensemble with a narrow Doppler width. Here, we use a dispersive measurement of light passing through a moving room temperature atomic vapor cell to determine the velocity of the cell in a single shot with a short-term sensitivity of 5.5 μm s^{-1} Hz^{-1/2}. The dispersion of the medium is enhanced by creating quantum interference through an auxiliary transition for the probe light under electromagnetically induced transparency condition. In contrast to measurement of single atoms, this method is based on the collective motion of atoms and can sense the c.m. velocity of an ensemble without knowing its velocity distribution. Our results improve the previous measurements by 3 orders of magnitude and can be used to design a compact motional sensor based on thermal atoms.
We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.
The temperature of the alkali metal cell, which affects the density of the alkali-metal vapor and the gas pressure, is usually difficult to measure directly. However, the temperature of the alkali-metal cell and the density of the alkali-metal vapor are important parameters that affect the performance of the atomic sensor. In this paper, a device that can directly measure the internal temperature of an alkali metal cell in real time is designed for the first time to explore the relationship between alkali-metal vapor density and temperature. Alkali-metal vapor density is measured using the absorption spectrum. The pressure broadening model, combined with the transition of four hyperfine levels, was used to fit the absorption line of 87Rb D1 under the action of 700 Torr N2, and a good fitting effect was obtained. The experimental results show that the density of 87Rb is less than the value calculated by the empirical formula. Based on the experimental results, we give the calculation formula of 87Rb density with an uncertainty of only 4% and obtain the temperature dependence index of the line width and linear displacement of 87Rb in N2 by analyzing the absorption spectrum.