Physical Review Letters

10 dB Quantum-Enhanced Michelson Interferometer with Balanced Homodyne Detection

J. Heinze, K. Danzmann, B. Willke, H. Vahlbruch

Published Jul 11, 2022• 26 citations
Publisher

Abstract

Future generations of gravitational-wave detectors (GWD) are targeting an effective quantum noise reduction of 10 dB via the application of squeezed states of light. In the last joint observation run O3, the advanced large-scale GWDs LIGO and Virgo already used the squeezing technology, albeit with a moderate efficiency. Here, we report on the first successful 10 dB sensitivity enhancement of a shot-noise limited tabletop Michelson interferometer via squeezed light in the fundamental Gaussian laser mode, where we also implement the balanced homodyne detection scheme that is planned for the third GWD generation. In addition, we achieved a similarly strong quantum noise reduction when the interferometer was operated in higher-order Hermite-Gaussian modes, which are discussed for the GWD thermal noise mitigation. Our results are an important step toward the targeted quantum noise level in future GWDs and, moreover, represent significant progress in the application of nonclassical states in higher-order modes for interferometry, increased spatial resolution, and multichannel sensing.

DOI
10.1103/physrevlett.129.031101

Related papers

Squeezed States of Light for Future Gravitational Wave Detectors at a Wavelength of 1550 nm

Fabian Meylahn, B. Willke, H. Vahlbruch

The generation of strongly squeezed vacuum states of light is a key technology for future ground-based gravitational wave detectors (GWDs) to reach sensitivities beyond their quantum noise limit. For some proposed observatory designs, an operating laser wavelength of 1550 nm or around 2 μm is required to enable the use of cryogenically cooled silicon test masses for thermal noise reduction. Here, we present for the first time the direct measurement of up to 11.5 dB squeezing at 1550 nm over the complete detection bandwidth of future ground-based GWDs ranging from 10 kHz down to below 1 Hz. Furthermore, we directly observe a quantum shot-noise reduction of up to (13.5±0.1) dB at megahertz frequencies. This allows us to derive a precise constraint on the absolute quantum efficiency of the photodiode used for balanced homodyne detection. These results hold important insight regarding the quantum noise reduction efficiency in future GWDs, as well as for quantum information and cryptography, where low decoherence of nonclassical states of light is also of high relevance.

Physical Review Letters•Sep 16, 2022•42 citations

Quantum enhancement of a 4km laser interferometer gravitational-wave detector

S. Chua

The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.

•Jan 1, 2013•1 citation

First Demonstration of 6 dB Quantum Noise Reduction in a Kilometer Scale Gravitational Wave Observatory

J. D. Lough, Emil Schreiber, F. Bergamin +14 more

Photon shot noise, arising from the quantum-mechanical nature of the light, currently limits the sensitivity of all the gravitational wave observatories at frequencies above one kilohertz. We report a successful application of squeezed vacuum states of light at the GEO 600 observatory and demonstrate for the first time a reduction of quantum noise up to 6.03±0.02 dB in a kilometer scale interferometer. This is equivalent at high frequencies to increasing the laser power circulating in the interferometer by a factor of 4. Achieving this milestone, a key goal for the upgrades of the advanced detectors required a better understanding of the noise sources and losses and implementation of robust control schemes to mitigate their contributions. In particular, we address the optical losses from beam propagation, phase noise from the squeezing ellipse, and backscattered light from the squeezed light source. The expertise gained from this work carried out at GEO 600 provides insight toward the implementation of 10 dB of squeezing envisioned for third-generation gravitational wave detectors.

arXiv:2005.10292•Physical Review Letters•Jan 26, 2021•107 citations

Quantum noise reduction for gravitational-wave interferometers with non-classical states

M. J. Yap

The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.

•Jan 1, 2020•0 citations

Observation of Squeezed States of Light in Higher-Order Hermite-Gaussian Modes with a Quantum Noise Reduction of up to 10 dB

J. Heinze, B. Willke, H. Vahlbruch

Mirror thermal noise will be a main limitation for the sensitivities of the next-generation ground-based gravitational-wave detectors (Einstein Telescope and Cosmic Explorer) at signal frequencies around 100 Hz. Using a higher-order spatial laser mode instead of the fundamental mode is one proposed method to further mitigate mirror thermal noise. In the current detectors, quantum noise is successfully reduced by the injection of squeezed vacuum states. The operation in a higher-order mode would then require the efficient generation of squeezed vacuum states in this mode to maintain a high quantum noise reduction. In our setup, we generate continuous-wave squeezed states at a wavelength of 1064 nm in the fundamental and three higher-order Hermite-Gaussian modes up to a mode order of 6 using a type-I optical parametric amplifier. We present a significant milestone with a quantum noise reduction of up to 10 dB at a measurement frequency of 4 MHz in the higher-order modes and pave the way for their usage in future gravitational-wave detectors as well as in other quantum noise limited experiments.

Physical Review Letters•Feb 25, 2022•27 citations

Balanced Homodyne Detection of Optical Quantum States at Audio-Band Frequencies and Below

Michael Stefszky, Conor M Mow-Lowry, S. Chua +7 more

The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.

•Jan 1, 2012•67 citations
Future generations of gravitational-wave detectors (GWD) are targeting an effective quantum noise reduction of 10 dB via the application of squeezed states of light. In the last joint observation run O3, the advanced large-scale GWDs LIGO and Virgo already used the squeezing technology, albeit with a moderate efficiency. Here, we report on the first successful 10 dB sensitivity enhancement of a shot-noise limited tabletop Michelson interferometer via squeezed light in the fundamental Gaussian laser mode, where we also implement the balanced homodyne detection scheme that is planned for the third GWD generation. In addition, we achieved a similarly strong quantum noise reduction when the interferometer was operated in higher-order Hermite-Gaussian modes, which are discussed for the GWD thermal noise mitigation. Our results are an important step toward the targeted quantum noise level in future GWDs and, moreover, represent significant progress in the application of nonclassical states in higher-order modes for interferometry, increased spatial resolution, and multichannel sensing.
The generation of strongly squeezed vacuum states of light is a key technology for future ground-based gravitational wave detectors (GWDs) to reach sensitivities beyond their quantum noise limit. For some proposed observatory designs, an operating laser wavelength of 1550 nm or around 2 μm is required to enable the use of cryogenically cooled silicon test masses for thermal noise reduction. Here, we present for the first time the direct measurement of up to 11.5 dB squeezing at 1550 nm over the complete detection bandwidth of future ground-based GWDs ranging from 10 kHz down to below 1 Hz. Furthermore, we directly observe a quantum shot-noise reduction of up to (13.5±0.1) dB at megahertz frequencies. This allows us to derive a precise constraint on the absolute quantum efficiency of the photodiode used for balanced homodyne detection. These results hold important insight regarding the quantum noise reduction efficiency in future GWDs, as well as for quantum information and cryptography, where low decoherence of nonclassical states of light is also of high relevance.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.
Photon shot noise, arising from the quantum-mechanical nature of the light, currently limits the sensitivity of all the gravitational wave observatories at frequencies above one kilohertz. We report a successful application of squeezed vacuum states of light at the GEO 600 observatory and demonstrate for the first time a reduction of quantum noise up to 6.03±0.02 dB in a kilometer scale interferometer. This is equivalent at high frequencies to increasing the laser power circulating in the interferometer by a factor of 4. Achieving this milestone, a key goal for the upgrades of the advanced detectors required a better understanding of the noise sources and losses and implementation of robust control schemes to mitigate their contributions. In particular, we address the optical losses from beam propagation, phase noise from the squeezing ellipse, and backscattered light from the squeezed light source. The expertise gained from this work carried out at GEO 600 provides insight toward the implementation of 10 dB of squeezing envisioned for third-generation gravitational wave detectors.
The detection of the binary neutron star inspiral GW170817 by the Advanced Laser Interferometer Gravitational Wave Observatory (LIGO) and Advanced Virgo, followed by counterpart observations across a broad electromagnetic spectrum, marks the dawn of multi-messenger astronomy. The discovery rate and potential of gravitational-wave astronomy is limited by the detector's sensitivity. A key challenge in improving the sensitivity of gravitational-wave detectors is to reduce quantum noise which arises due to the quantum nature of light. A well established technique to reduce the quantum noise in the detector is by replacing the coherent vacuum fluctuations entering the readout port with a squeezed vacuum state. This technique has been successfully demonstrated at the GEO-600 and LIGO Hanford detector, and is now in routine operation in current gravitational wave detectors. This thesis presents research from three experiments to develop quantum noise reduction techniques for next-generation gravitational wave detector using non-classical quantum states such as squeezed states. Current proposals for future generation gravitational wave detectors, such as LIGO Voyager, plan to utilise cryogenic silicon instead of fused silica as the test mass material. This is to improve the power handling of the detector and reduce thermal noise. The switch to silicon test masses requires a change of laser wavelength to the 2 micron region. In the first experiment, we built and operated the first squeezed vacuum source at a wavelength of 1984 nm. With a stable squeezing ellipse phase control employed, 3.9 dB of squeezing was measured, predominately limited by losses due to the low quantum efficiency of the photodiode. The squeezed vacuum system presented is compatible with future detectors and is a key pathfinder experiment to inform the design of cryogenic silicon interferometers. The quantum nature of light results in quantum radiation pressure noise that limits the low frequency sensitivity of gravitational wave detectors. In collaboration with Louisiana State University, the second experiment demonstrates the reduction of quantum radiation pressure noise by injecting bright squeezed light into a centimetre-scale optomechanical cavity at room temperature. The experiment involves the development and integration of a low-frequency bright squeezed source to reduce the quantum radiation pressure noise by 1.2 dB at 20 kHz. The result also represents the lowest frequency bright squeezed state measured from a crystal-based squeezer. Quadrature rotation of the injected squeezed state is required to achieve broadband quantum noise reduction in gravitational wave detectors due to the quantum back-action effect. This requires the squeezed state to interact with a low loss optical filter with a low frequency bandwidth prior to injection and represents a significant technical challenge. The final experiment presented in this thesis demonstrates an alternate method where frequency-dependent squeezing with Einstein-Podolsky-Rosen (EPR) entangled states is generated. When integrated into a gravitational wave detector, the alternate method allows the detector to simultaneously serve as the optical filter, eliminating the need for the additional apparatus.
Mirror thermal noise will be a main limitation for the sensitivities of the next-generation ground-based gravitational-wave detectors (Einstein Telescope and Cosmic Explorer) at signal frequencies around 100 Hz. Using a higher-order spatial laser mode instead of the fundamental mode is one proposed method to further mitigate mirror thermal noise. In the current detectors, quantum noise is successfully reduced by the injection of squeezed vacuum states. The operation in a higher-order mode would then require the efficient generation of squeezed vacuum states in this mode to maintain a high quantum noise reduction. In our setup, we generate continuous-wave squeezed states at a wavelength of 1064 nm in the fundamental and three higher-order Hermite-Gaussian modes up to a mode order of 6 using a type-I optical parametric amplifier. We present a significant milestone with a quantum noise reduction of up to 10 dB at a measurement frequency of 4 MHz in the higher-order modes and pave the way for their usage in future gravitational-wave detectors as well as in other quantum noise limited experiments.
The advent of stable, highly squeezed states of light has generated great interest in the gravitational wave community as a means for improving the quantumnoise- limited performance of advanced interferometric detectors. To confidently measure these squeezed states, it is first necessary to measure the shot-noise across the frequency band of interest. Technical noise, such as non-stationary events, beam pointing, and parasitic interference, can corrupt shot-noise measurements at low Fourier frequencies, below tens of kilo-Hertz. In this paper we present a qualitative investigation into all of the relevant noise sources and the methods by which they can be identified and mitigated in order to achieve quantum noise limited balanced homodyne detection. Using these techniques, flat shot-noise down to Fourier frequencies below 0.5 Hz is produced. This enables the direct observation of large magnitudes of squeezing across the entire audio-band, of particular interest for ground-based interferometric gravitational wave detectors. 11.6 dB of shot-noise suppression is directly observed, with more than 10 dB down to 10 Hz.