Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer series in chemical physics

Two Dimensional Analysis of Integrated Three Pulse Photon Echo

Yutaka Nagasawa, Kazushige Seike, Takayuki Muromoto, Tadashi Okada

Published Jan 1, 2003• 0 citations
Publisher
DOI
10.1007/978-3-642-59319-2_176

Related papers

Vibrational and Electronic Coherence Observed in Two-Dimensional Integrated Three-Pulse Photon Echo

Yutaka Nagasawa, Mayu Ogasawara, Yukako Nakagawa +3 more

Springer series in chemical physics•Jan 1, 2005•0 citations

Two-Dimensional Representation of Three-Pulse Photon Echo

Yutaka Nagasawa, Tadashi Okada, Tadayuki Muromoto +1 more

•Jan 1, 2003•0 citations

A Research on the Relation Between the Integrated Three-Pulse Photon Echo Signal and the Correlation Function

Zhonghua Zhang, Jia Chen, Yang Zhao +1 more

Russian Physics Journal•Mar 1, 2014•0 citations

Two-Color Three Pulse Photon Echo Peak Shift Spectroscopy

Ritesh Agarwal, Bradley S. Prall, Abbas H. Rizvi +2 more

Springer series in chemical physics•Jan 1, 2003•0 citations

Two dimensional analysis of integrated three pulse photon echo

Yutaka Nagasawa, Kazushige Seike, Tadayuki Muromoto +1 more

We have carried out two-dimensional measurement of integrated three-pulse photon echo signal of Nile blue doped in poly(methyl methacrylate) (PMMA) at various temperatures (30-230 K). Rephasing and echo formation were still clear even when the population period was extended to >100 ps, indicating that spectral diffusion is a minor process in the picosecond time scale for this sample. The intramolecular vibrational relaxation did not cause a sufficient spectral diffusion.

International Conference on Ultrafast Phenomena•Jan 1, 2002•0 citations

Two-Dimensional Analysis of Integrated Three-Pulse Photon Echo Signals of Nile Blue Doped in PMMA

Yutaka Nagasawa, Kazushige Seike, Takayuki Muromoto +1 more

The integrated three-pulse photon echo signal of Nile blue doped in poly(methyl methacrylate) (PMMA) was measured two-dimensionally by varying the first coherence period and the subsequent population period. The electronic dephasing time was in the femtosecond time range even at low temperatures, whereas rephasing and echo formation were still possible even when the population period was extended to >100 ps. Oscillation was present in the echo signal even when population period was extended to longer values than the dephasing time of the vibrational coherence. Echo peak shift measurement indicated a presence of small spectral diffusion in the picosecond time range. A computer simulation was carried out from a model spectral density. The phonon mode of PMMA was represented by a Brownian oscillator centered at ∼116 cm -1, and it reproduced the temperature dependence of the echo signal surprisingly well.

The Journal of Physical Chemistry A•Mar 14, 2003•31 citations
The integrated three-pulse photon echo signal of Nile blue doped in poly(methyl methacrylate) (PMMA) was measured two-dimensionally by varying the first coherence period and the subsequent population period. The electronic dephasing time was in the femtosecond time range even at low temperatures, whereas rephasing and echo formation were still possible even when the population period was extended to >100 ps. Oscillation was present in the echo signal even when population period was extended to longer values than the dephasing time of the vibrational coherence. Echo peak shift measurement indicated a presence of small spectral diffusion in the picosecond time range. A computer simulation was carried out from a model spectral density. The phonon mode of PMMA was represented by a Brownian oscillator centered at ∼116 cm -1, and it reproduced the temperature dependence of the echo signal surprisingly well.