Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Temperature measurement of 6He + ions confined in a transparent Paul trap

X. Fléchard, G. Ban, D. Durand, Etienne Liénard, F. Mauger, A. Méry, O. Naviliat-Cuncic, Daniel Rodríguez, Ph. Velten

Published Jan 1, 2011• 0 citations
Publisher
DOI
10.1007/978-94-007-2588-1_3

Related papers

Quantum thermometry with trapped ions

Peter A. Ivanov

arXiv:1809.01451•Optics Communications•Dec 7, 2018•16 citations

Measurement of the Coulomb Logarithm in a Radio-Frequency Paul Trap

Kuang Chen, Scott T. Sullivan, Wade G. Rellergert +1 more

Samples of ultracold 174Yb+ ions, confined in a linear radio-frequency Paul trap, are heated via micromotion interruption, while their temperature, density, and therefore structural phase are monitored and simulated. The observed time evolution of the ion temperature is compared to a theoretical model for ion-ion heating allowing a direct measurement of the Coulomb logarithm in a linear Paul trap. This result permits a simple, yet accurate, analytical description of ion cloud thermodynamic properties, e.g., density, temperature, and structural phase, as well as suggests limits to and improvements for ongoing trapped-ion quantum information efforts.

arXiv:1211.1659•Physical Review Letters•Apr 23, 2013•25 citations

Quantum-limited measurements on trapped laser-cooled ions

Cassius D'Helon

•Jan 1, 1997•0 citations

Sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for Microwave Ion Clocks

J. Z. Han, H. R. Qin, Limin Guo +6 more

We report sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of $^{113}$Cd$^+$ ions was achieved. The temperature of these ions was measured at $90(10)$ mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of $2\times10^{-17}$. Up to $4.2\times10^5$ Cd$^+$ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still $10^5$ Cd$^+$ ions present, indicating that this Ca$^+$--Cd$^+$ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca$^+$ lasers and fluorescence, which was carefully estimated to an accuracy of $5.4(0.5)\times10^{-17}$ using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.

arXiv:2002.04228•Feb 11, 2020•0 citations

Temperature dependence of decoherence in ion traps

Jaroslaw Labaziewicz, Yufei Ge, Shannon X. Wang +2 more

Bulletin of the American Physical Society•Mar 10, 2008•0 citations

Trapping of gold anions in a linear Paul trap

Stefan Erlewein

In order to demonstrate laser cooling on negatively charged ions, it is necessary to confine the ions in a region free of strong magnetic fields. In the course of this thesis, the pre-existing design of a linear Paul trap was modified and taken into operation. The new design possesses two additional end cap electrodes whose shape provides effective axial confinement without blocking optical access to the trapped particles. The influence of these end cap electrodes on the trapping potential was simulated and compared to experimental results. Measurements with AU- ions show that the trap allows storage of ions for multiple hours. Analysis ofthe storage time suggests that the loading process heats up the trapped ions. The lifetime τHot of the hot ions was determined to be 23(3) min. After thermalization, the lifetime increases to 75(2) min. Measurements of the ion cloud’s radius provide an estimation of the equilibrium temperature T∞ ≈5000 K. The experimentally determined time constant of the cooling process is τcool = 41:6(4) s.

•Jan 1, 2017•0 citations
Samples of ultracold 174Yb+ ions, confined in a linear radio-frequency Paul trap, are heated via micromotion interruption, while their temperature, density, and therefore structural phase are monitored and simulated. The observed time evolution of the ion temperature is compared to a theoretical model for ion-ion heating allowing a direct measurement of the Coulomb logarithm in a linear Paul trap. This result permits a simple, yet accurate, analytical description of ion cloud thermodynamic properties, e.g., density, temperature, and structural phase, as well as suggests limits to and improvements for ongoing trapped-ion quantum information efforts.
Sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for Microwave Ion Clocks
We report sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of 113^{113}113Cd+^++ ions was achieved. The temperature of these ions was measured at 90(10)90(10)90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of 2×10−172\times10^{-17}2×10−17. Up to 4.2×1054.2\times10^54.2×105 Cd+^++ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still 10510^5105 Cd+^++ ions present, indicating that this Ca+^++--Cd+^++ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca+^++ lasers and fluorescence, which was carefully estimated to an accuracy of 5.4(0.5)×10−175.4(0.5)\times10^{-17}5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.
In order to demonstrate laser cooling on negatively charged ions, it is necessary to confine the ions in a region free of strong magnetic fields. In the course of this thesis, the pre-existing design of a linear Paul trap was modified and taken into operation. The new design possesses two additional end cap electrodes whose shape provides effective axial confinement without blocking optical access to the trapped particles. The influence of these end cap electrodes on the trapping potential was simulated and compared to experimental results. Measurements with AU- ions show that the trap allows storage of ions for multiple hours. Analysis ofthe storage time suggests that the loading process heats up the trapped ions. The lifetime τHot of the hot ions was determined to be 23(3) min. After thermalization, the lifetime increases to 75(2) min. Measurements of the ion cloud’s radius provide an estimation of the equilibrium temperature T∞ ≈5000 K. The experimentally determined time constant of the cooling process is τcool = 41:6(4) s.