Physical Review A

Micromaser linewidth

Rebecca R. McGowan, William C. Schieve

Published May 1, 1997• 8 citations
Publisher

Abstract

In earlier papers, the linewidth of a micromaser was approximated by a phase diffusion rate that was obtained using a single decay rate assumption to model the decay of the electric field in the micromaser cavity. These methods gave analytic but approximate answers. Exact methods calculated the spectrum via the two-time correlation function, but required extensive numerical calculations. In this paper, we present an approximate analytic derivation of the micromaser spectrum via the two-time correlation function that is more accurate than other approximate analytic methods yet requires much less numerical calculation than the exact methods. We also review the other methods, both analytical and exact, and present numerical comparisons.

DOI
10.1103/physreva.55.3813

Related papers

Calculation of the micromaser spectrum. I. Green’s-function approach and approximate analytical techniques

Tran Quang, G. S. Agarwal, János A. Bergou +4 more

We first calculate the ``exact'' micromaser spectrum by solving numerically for the Green's function of the approximate master equation for the one-atom (micro-) maser. We then proceed to calculate approximate analytical expressions for the maser linewidth using (i) a phase-operator approach, (ii) an ansatz similar to the standard quantum theory of the laser, and (iii) a linear expansion of the correlation function. Novel features, quite distinct from the familiar Schawlow-Townes linewidth, are found, e.g., the linewidth decreases as the number of thermal photons increases.

Physical Review A•Jul 1, 1993•47 citations

Micromaser spectrum: Trapped states

Ning Lu

We study the spectrum of a one-photon micromaser through the approach of the two-time correlation function. First, we derive two general formulas for the two-time correlation function and for the micromaser spectrum. Then, we focus our attention on trapped states of the micromaser. We examine the line shapes and linewidth of the micromaser spectrum. We find that the half width at half maximum of the spectrum can be less than the smallest decay rate of the off-diagonal density matrix elements ${\mathrm{\ensuremath{\rho}}}_{\mathit{n},}$${\mathit{n}}_{+1}$(t), that a hole can appear at the center of the spectrum, and that the spectrum can be split by shifted spectral components. Using a simple example in which the micromaser spectrum is exactly Lorentzian, we also show that two very close photon-number distributions can correspond to two very different natural linewidths.

Physical Review A•Feb 1, 1993•20 citations

Subnarrow linewidth, hole, and split in micromaser spectrum

Ning Lu

By calculating the two-time correlation function of a one-photon micromaser, we study the line shapes and linewidth of the micromaser spectrum. We find that the half-width at half maximum of the spectrum can be less than the smallest decay rate of the off-diagonal density-matrix elements ${\mathrm{\ensuremath{\rho}}}_{\mathit{n},}$${\mathit{n}}_{+1}$, that a hole can appear in the spectrum, and that the spectrum can be split by shifted spectral components.

Physical Review Letters•Feb 15, 1993•19 citations

Micromaser spectrum and phase diffusion dynamics

Federico Casagrande, Alessandro Ferraro, ALFREDO LULLI +3 more

We discuss a scheme to relate the phase diffusion dynamics of the micromaser field to the measured atomic population statistics. This can allow us to measure the linewidth of the micromaser spectrum and to solve a relevant decoherence problem in cavity quantum electrodynamics. The main steps are (i) a suitable preparation of the cavity field state to generate coherences, (ii) the transfer of information on the dynamics of field coherences to probe atoms by the action of an external resonant coherent field and (iii) the derivation of the phase diffusion rate, hence the micromaser linewidth, from the measured population statistics of the probe atoms. The method can be applied even in the presence of trapping states, where peculiar linewidth oscillations are expected for increasing pump rate, due to the quantum nature of the micromaser field.

Journal of Optics B Quantum and Semiclassical Optics•Aug 1, 2003•3 citations

Exact calculation of the natural linewidth for a one-photon micromaser

Shahid Qamar, Muhammad Suhail Zubairy

The natural linewidth of a one-photon micromaser for a certain choice of interaction time has been calculated using the exact solution of a second-order correlation function. A comparison is made with the corresponding linewidth of a laser.

Physical Review A•Dec 1, 1991•17 citations

Micromaser with injected atomic phase

Rebecca R. McGowan, William C. Schieve

Both approximate and exact methods exist to determine the density matrix of the field inside an incoherently driven micromaser, but as of yet only a steady-state Fokker-Planck solution has been found for the micromaser with injected atomic phase [Phys. Rev. A 34, 2032 (1986)]. Since Fokker-Planck solutions have been shown not to represent the effect of trapping states on the cavity field adequately, other solutions must be sought. In this paper, we present both a highly accurate approximate analytical solution and a more computationally complex numerical solution based on the exact methods of Lu [Phys. Rev. A 47, 1347 (1993)], both of which demonstrate symmetry breaking in the phase. Since the spectra of the injected phase micromaser will be the same as that of the incoherently pumped case, we present numerical comparisons of our two solutions via the phase variance.

Physical Review A•Sep 1, 1997•11 citations
In earlier papers, the linewidth of a micromaser was approximated by a phase diffusion rate that was obtained using a single decay rate assumption to model the decay of the electric field in the micromaser cavity. These methods gave analytic but approximate answers. Exact methods calculated the spectrum via the two-time correlation function, but required extensive numerical calculations. In this paper, we present an approximate analytic derivation of the micromaser spectrum via the two-time correlation function that is more accurate than other approximate analytic methods yet requires much less numerical calculation than the exact methods. We also review the other methods, both analytical and exact, and present numerical comparisons.
We first calculate the ``exact'' micromaser spectrum by solving numerically for the Green's function of the approximate master equation for the one-atom (micro-) maser. We then proceed to calculate approximate analytical expressions for the maser linewidth using (i) a phase-operator approach, (ii) an ansatz similar to the standard quantum theory of the laser, and (iii) a linear expansion of the correlation function. Novel features, quite distinct from the familiar Schawlow-Townes linewidth, are found, e.g., the linewidth decreases as the number of thermal photons increases.
We study the spectrum of a one-photon micromaser through the approach of the two-time correlation function. First, we derive two general formulas for the two-time correlation function and for the micromaser spectrum. Then, we focus our attention on trapped states of the micromaser. We examine the line shapes and linewidth of the micromaser spectrum. We find that the half width at half maximum of the spectrum can be less than the smallest decay rate of the off-diagonal density matrix elements ${\mathrm{\ensuremath{\rho}}}_{\mathit{n},}$n+1{\mathit{n}}_{+1}n+1​(t), that a hole can appear at the center of the spectrum, and that the spectrum can be split by shifted spectral components. Using a simple example in which the micromaser spectrum is exactly Lorentzian, we also show that two very close photon-number distributions can correspond to two very different natural linewidths.
By calculating the two-time correlation function of a one-photon micromaser, we study the line shapes and linewidth of the micromaser spectrum. We find that the half-width at half maximum of the spectrum can be less than the smallest decay rate of the off-diagonal density-matrix elements ${\mathrm{\ensuremath{\rho}}}_{\mathit{n},}$n+1{\mathit{n}}_{+1}n+1​, that a hole can appear in the spectrum, and that the spectrum can be split by shifted spectral components.
We discuss a scheme to relate the phase diffusion dynamics of the micromaser field to the measured atomic population statistics. This can allow us to measure the linewidth of the micromaser spectrum and to solve a relevant decoherence problem in cavity quantum electrodynamics. The main steps are (i) a suitable preparation of the cavity field state to generate coherences, (ii) the transfer of information on the dynamics of field coherences to probe atoms by the action of an external resonant coherent field and (iii) the derivation of the phase diffusion rate, hence the micromaser linewidth, from the measured population statistics of the probe atoms. The method can be applied even in the presence of trapping states, where peculiar linewidth oscillations are expected for increasing pump rate, due to the quantum nature of the micromaser field.
Both approximate and exact methods exist to determine the density matrix of the field inside an incoherently driven micromaser, but as of yet only a steady-state Fokker-Planck solution has been found for the micromaser with injected atomic phase [Phys. Rev. A 34, 2032 (1986)]. Since Fokker-Planck solutions have been shown not to represent the effect of trapping states on the cavity field adequately, other solutions must be sought. In this paper, we present both a highly accurate approximate analytical solution and a more computationally complex numerical solution based on the exact methods of Lu [Phys. Rev. A 47, 1347 (1993)], both of which demonstrate symmetry breaking in the phase. Since the spectra of the injected phase micromaser will be the same as that of the incoherently pumped case, we present numerical comparisons of our two solutions via the phase variance.