Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Publications of the Astronomical Society of Australia

Intensity correlation functions of microwave maser sources

Andrey V. Shepelev

Published Apr 4, 2022• 0 citations
Publisher

Abstract

Astrophysical sources of microwave radiation with extremely high spectral brightness are interpreted as masers. But by itself, the information about high brightness of radiation does not make it possible to establish whether the radiation is thermal or maser. This can be determined only on the basis of the analysis of high-order correlation functions. A possible measurement procedure for the second-order autocorrelation function (the bunching parameter) for these sources is proposed.

DOI
10.1017/pasa.2022.11

Related papers

Intensity correlation speckles as a technique for removing Doppler broadening

Roberto D. Merlin, Noah Green, István Szapudi +1 more

A method involving intensity correlation measurements is described, which allows for the complete removal of Doppler broadening in the emission of electromagnetic radiation from faraway sources that are inaccessible to conventional Doppler-free measurements. The technique, relying on a correction to ${g}^{(2)}$ of order ${N}^{\ensuremath{-}1}$, probes the separation between neighboring spectral lines and is also applicable to the elimination of broadening due to collisions ($N$ is the number of emitting particles and ${g}^{(2)}$ is the second-order field correlation function). Possible applications include a determination of cosmological parameters from redshifts of gravitationally lensed quasars.

arXiv:2104.10200•Physical Review A•Apr 12, 2021•2 citations

Optical harmonic generation enhanced due to ultrafast intensity fluctuations (Conference Presentation)

Denis A. Kopylov, Kirill Yu. Spasibko, Victor L. Krutyanskiy +3 more

The effect of the quantum properties of light on nonlinear processes has been well studied theoretically. It has been shown that the efficiency of n-photon nonlinear processes in many cases scales as the normalized n-th order correlation function. For light with high intensity correlation function, the efficiency of the n-th harmonic generation will be considerably higher than for coherent light. The experimental observation of this effect remained difficult until recently, because of the absence of bright sources with strong and fast intensity fluctuations. For the experimental demonstration of statistical effects in optical harmonic generation we use as a pump the radiation of high-gain parametric down conversion. Such light shows quantum properties (e.g. quadrature or two-mode squeezing) and has large number of photons in one mode. The normalized n-th order correlation function for this light is (2n - 1)!!, which makes it more attractive for nonlinear processes than both coherent and thermal light. For the generation of optical harmonics we used broadband parametric down conversion around frequency-degeneracy (1600 nm) produced in 1cm BBO crystal from Ti:Sapphire laser (800 nm, 1.6ps, 5kHz, 3W mean intensity). Due to spectral filtering and post-selection technique we could vary the statistics of light from coherent to super-bunched, which allowed us to demonstrate the efficiency enhancement for second-, third-, and fourth-harmonic generation. The obtained experimental results show a good agreement with the theory.

•Jun 8, 2017•0 citations

Autocorrelation function for thermal noise in the case of maser amplifiers

Renuka Jindal, Aldert van der Ziel

This paper gives the autocorrelation function of thermal noise when the zero point energy noise term is neglected. Such a situation applies to maser amplifiers.

IEEE Journal of Quantum Electronics•Feb 1, 1981•1 citation

LIDAR with Optically Amplified Thermal Light

Darren Ming Zhi Koh, Peng Kian Tan, Christian Kurtsiefer

Thermal light exhibits intensity fluctuations or photon bunching that has been used as a source of entropy or temporally correlated light. However, its low spectral density limits its use in practical applications like LIDAR. One method of remedying this is optical amplification to boost its brightness. In this paper, we show that the normalized second order coherence function $g^{(2)}(τ)$ of a thermal light source is preserved after amplification. We then use amplified thermal light to demonstrate a LIDAR raster scan of a building at 1.3 km with a depth resolution of 2 cm.

physics.opticsCross-listedarXiv:2610.26082•Oct 20, 2026

Theory of Cavity Masers

D. E. McCumber

Simple interference experiments identify correlation functions which describe the response of maser amplifiers and the output of maser oscillators. General operator techniques are used to evaluate these functions in cavity maser systems for which the coupling of the maser electromagnetic field to external energy sources or sinks is mediated by systems whose short-term response depends primarily upon average or macroscopic system properties. The dielectric theory which results includes only those short-term non-linearities associated with the external pumping fields. In the long term both the external and the cavity fields can modify the susceptibility functions. The techniques utilized permit a detailed analysis of approximations and suggest generalizations for increased precision. As one important result of this type the theory indicates that macroscopic rate equations are valid if modulation frequencies are much less than the width of the narrowest coupling system spectral line.

Physical Review•Apr 15, 1963•25 citations

Calculation of the micromaser spectrum. I. Green’s-function approach and approximate analytical techniques

Tran Quang, G. S. Agarwal, János A. Bergou +4 more

We first calculate the ``exact'' micromaser spectrum by solving numerically for the Green's function of the approximate master equation for the one-atom (micro-) maser. We then proceed to calculate approximate analytical expressions for the maser linewidth using (i) a phase-operator approach, (ii) an ansatz similar to the standard quantum theory of the laser, and (iii) a linear expansion of the correlation function. Novel features, quite distinct from the familiar Schawlow-Townes linewidth, are found, e.g., the linewidth decreases as the number of thermal photons increases.

Physical Review A•Jul 1, 1993•55 citations
Astrophysical sources of microwave radiation with extremely high spectral brightness are interpreted as masers. But by itself, the information about high brightness of radiation does not make it possible to establish whether the radiation is thermal or maser. This can be determined only on the basis of the analysis of high-order correlation functions. A possible measurement procedure for the second-order autocorrelation function (the bunching parameter) for these sources is proposed.
A method involving intensity correlation measurements is described, which allows for the complete removal of Doppler broadening in the emission of electromagnetic radiation from faraway sources that are inaccessible to conventional Doppler-free measurements. The technique, relying on a correction to g(2){g}^{(2)}g(2) of order ${N}^{\ensuremath{-}1}$, probes the separation between neighboring spectral lines and is also applicable to the elimination of broadening due to collisions (NNN is the number of emitting particles and g(2){g}^{(2)}g(2) is the second-order field correlation function). Possible applications include a determination of cosmological parameters from redshifts of gravitationally lensed quasars.
The effect of the quantum properties of light on nonlinear processes has been well studied theoretically. It has been shown that the efficiency of n-photon nonlinear processes in many cases scales as the normalized n-th order correlation function. For light with high intensity correlation function, the efficiency of the n-th harmonic generation will be considerably higher than for coherent light. The experimental observation of this effect remained difficult until recently, because of the absence of bright sources with strong and fast intensity fluctuations. For the experimental demonstration of statistical effects in optical harmonic generation we use as a pump the radiation of high-gain parametric down conversion. Such light shows quantum properties (e.g. quadrature or two-mode squeezing) and has large number of photons in one mode. The normalized n-th order correlation function for this light is (2n - 1)!!, which makes it more attractive for nonlinear processes than both coherent and thermal light. For the generation of optical harmonics we used broadband parametric down conversion around frequency-degeneracy (1600 nm) produced in 1cm BBO crystal from Ti:Sapphire laser (800 nm, 1.6ps, 5kHz, 3W mean intensity). Due to spectral filtering and post-selection technique we could vary the statistics of light from coherent to super-bunched, which allowed us to demonstrate the efficiency enhancement for second-, third-, and fourth-harmonic generation. The obtained experimental results show a good agreement with the theory.
Thermal light exhibits intensity fluctuations or photon bunching that has been used as a source of entropy or temporally correlated light. However, its low spectral density limits its use in practical applications like LIDAR. One method of remedying this is optical amplification to boost its brightness. In this paper, we show that the normalized second order coherence function g(2)(τ)g^{(2)}(τ)g(2)(τ) of a thermal light source is preserved after amplification. We then use amplified thermal light to demonstrate a LIDAR raster scan of a building at 1.3 km with a depth resolution of 2 cm.
Simple interference experiments identify correlation functions which describe the response of maser amplifiers and the output of maser oscillators. General operator techniques are used to evaluate these functions in cavity maser systems for which the coupling of the maser electromagnetic field to external energy sources or sinks is mediated by systems whose short-term response depends primarily upon average or macroscopic system properties. The dielectric theory which results includes only those short-term non-linearities associated with the external pumping fields. In the long term both the external and the cavity fields can modify the susceptibility functions. The techniques utilized permit a detailed analysis of approximations and suggest generalizations for increased precision. As one important result of this type the theory indicates that macroscopic rate equations are valid if modulation frequencies are much less than the width of the narrowest coupling system spectral line.
We first calculate the ``exact'' micromaser spectrum by solving numerically for the Green's function of the approximate master equation for the one-atom (micro-) maser. We then proceed to calculate approximate analytical expressions for the maser linewidth using (i) a phase-operator approach, (ii) an ansatz similar to the standard quantum theory of the laser, and (iii) a linear expansion of the correlation function. Novel features, quite distinct from the familiar Schawlow-Townes linewidth, are found, e.g., the linewidth decreases as the number of thermal photons increases.