Vacuum pressure measurement based on 6Li cold atoms in a magneto-optical trap

Suzhao Zhang, Wenjun Sun, Meng Dong, Haibin Wu, R. X. Li, Xuejiao Zhang, Jingyi Zhang, Yongjun Cheng

Published Jan 1, 2022• 4 citations
Publisher

Abstract

Ultra-high vacuum measurement and extremely high vacuum (UHV/XHV) measurement play an important role in high-tech fields such as deep space exploration, particle accelerators, and nanoscience; with the continuous extension of the lower limit of measurement, especially when it reaches the order of 10–10 Pa, higher requirements are placed on the accuracy of the measurement. At present, in the field of UHV/XHV measurement, ionization gauges based on the principle of neutral gas ionization are commonly applied to the vacuum measurement. However, traditional ionization vacuum gauges during use can create electronic excitation desorption effects, soft X-rays, and the effect of hot cathode outgassing, thereby affecting the accuracy of measurement and limiting the lower limit of measurement. Compared with the traditional measurement technology, this method uses the relationship between the loss rate and pressure caused by the collision of cold atoms trapped in the trap depth with the background gas to calculate the gas density and inversely calculate the vacuum pressure. Based on the intrinsic quantum mechanical properties of cold atom collisions, this method is expected to be developed into a new vacuum traceability standard. In this paper, based on the small-angle approximation and impulse approximation under the quantum scattering theory, the loss rate coefficient of the collision of 6Li cold atoms with background gas molecules is calculated. According to the ideal gas equation, the pressure inversion formula is obtained. The collision loss rate is extracted by accurately fitting the loss curve of the cold atom. In order to improve the accuracy of vacuum inversion and reduce the influence of quantum diffractive collision on loss rate measurement, the trap depth under the conditions of a certain cooling laser intensity, detuning, and magnetic field gradient is determined by the photoassociation method. Finally, in a range of 1 × 10–8–5 × 10–6 Pa, the inverted pressure value is compared with the measured value of the ionization meter, proving that this method has good accuracy and reliability in the inversion of vacuum pressure. At present, the main factor restricting the improvement of accuracy is the influence of the collision between the excited atoms in the magneto-optical trap and the background gas on the loss rate measurement. In the future, with the proportion of excited atoms and the excited state C6 coefficient to be precisely determined, the uncertainty of vacuum pressure measurement can be further reduced.

DOI
10.7498/aps.71.20212204

Related papers

Ultra-high vacuum measurement based on 7Li cold atoms manipulation

Yongjun Cheng, Meng Dong, Wen-Jun Sun +5 more

The redefinition of the International System of Units (SI) promotes the transformation of the vacuum measurement system toward quantization, and the quantization of vacuum parameters is one of the most leading, prospective and subversive research directions in the field of international vacuum metrology, and the quantum vacuum measurement is based on the quantum effect of the microscopic particle system, and the use of optical means and the theory of quantum mechanics to realize the precision measurement of the vacuum parameters. We develop a lithium-cooled atom vacuum measurement apparatus, which mainly consists of a 7Li atom trap system and a continuous expansion vacuum system. In this work, an experimental study of ultrahigh vacuum measurement is carried out by manipulating 7Li atoms and utilizing the loss characteristics of lithium cold atoms in magneto-optical and magnetic traps, and the results show that for the four commonly used gas molecules in vacuum, namely N2, Ar, He, and H2, in the vacuum range of (3×10–8–4×10–5) Pa, the maximum measurement uncertainty is 7.6%–6.0% (k = 2) based on 7Li cold atoms, and the cold atom vacuum measurement results are in good agreement with those of the traditional ionization vacuum gauges, and their relative sensitivities are in good agreement with those of the ionization vacuum gauges, and the maximal deviation of the relative sensitivity factor is less than 8%, which verifies the accuracy and reliability of the cold-atom quantum vacuum measurements. The research results are of great significance in promoting the development of new cross-generation vacuum measurement technology and meeting the needs of space science exploration, ultra-precision measurement and high-end equipment manufacturing.

Acta Physica Sinica•Jan 1, 2024•1 citation

Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment

Jin-Peng Yuan, Zhong-Hua Ji, Yan-Ting Zhao +3 more

We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

arXiv:1304.7064•Applied Optics•Aug 21, 2013•23 citations

Vacuum pressure measurement of cold 7Li atoms in the magneto-optical and magnetic trap

Xuejiao Zhang, R. X. Li, Jingyi Zhang +2 more

Cold atoms play a very important role in metrology. The ultra-high or extreme-high vacuum pressure can be accurately measured by investigating the collision of cold atoms and residual atoms in the environment. We report a vacuum pressure metrometer using cold 7Li atoms as sensor atoms in a magneto-optical trap and a magnetic trap. The accuracy, uncertainty, and feasibility of the measurements in such two different traps are studied and compared in the pressure range from 10−5 to 10−8 Pa. It is found that the vacuum pressure measurement in a magneto-optical trap is more advantageous with a higher accuracy, higher signal-to-noise ratio, and shorter measurement time under current conditions. The results may be used to realize an applicable cold atom quantum vacuum standard.

AIP Advances•May 1, 2023•1 citation

Precise quantum measurement of vacuum with cold atoms

Daniel S. Barker, B. P. Acharya, James A. Fedchak +5 more

We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.

Review of Scientific Instruments•Dec 1, 2022•15 citations

Progress towards a primary pressure standard with cold atoms

Kais Jooya

This thesis describes a method of using an ultra-cold ensemble of atoms confined in a trap as an atomic primary pressure standard. The development of the standard and its current status are described in detail. This standard uses a 3D MOT to trap ⁸⁷Rb and then transfer them to a quadrupole magnetic trap where the atoms undergoes collisions with a background gas. By measuring the number of atoms left in the magnetic trap as a function of time one extract a loss rate and from this rate determine the background gas density. This loss rate is a product of the density of the background, multiplied by the loss cross section averaged over the velocity distribution of the background gas. By computing the average loss cross section in the magnetic trap and measuring the loss rate, the density of the background gas can be determined. This gives a calibration free measurement of density of a background gas in the UHV range (10-⁶ ‑ 10-⁹) Torr or (10-⁴ - 10-⁷) Pa which allows for it to be used as a standard. In conjunction with this, preparation of the atoms prior to the loss rate measurement is investigated to ensure accuracy and reproducibility of the standard. Finally a comparison between UBC's atomic standard and NIST's (National Institute for Standards and Technology) orifice flow standard is conducted via an ionization gauge which employed as a transfer standard.All measurement are carried out using Argon gas as the background gas of study.

•Jan 1, 2017•0 citations

Review of cold atom quantum-based vacuum metrology

Zhengwei FU, Xianghua HUANG, Junxiao LI +2 more

Quantum metrology technology is an advanced measurement method, which can achieve the accuracy that classical metrology is difficult to measure, and supplement the accuracy and stability defects caused by the standard quantum limit. In addition, reproducing quantum effects and quantum phenomena into units of metrology, which is obviously superior to the traditional measurement technology in terms of measurement accuracy, sensitivity and stability that could realize the quantum value transfer and traceability activities. With the development of laser cooling and trapping atom technology, the pressure measurement range of cold atom quantum-based vacuum metrology(CAVM) may reach 10-4~10-10 Pa or even lower . Benefiting from the loss rate of cold atoms in CAVM is only controlled by the collision cross section between cold atoms and gases, CAVM has the potential to develop into a emerging generation of vacuum metrology technology27. In this paper, the basic concept, structure and working principle of magneto-optical traps(MOT) for laser cooling atoms and trapping atoms are briefly described; Then, the basic principle of the CAVM is introduced. Furthermore, through collecting and sorting out a large number of literature about this technology, the advantages and key technologies of this technique in recent years are comprehensively analyzed and summarized; Finally, the developing trend of the CAVM is prospected.

Advanced Fiber Laser Conference (AFL)•Mar 18, 2024•1 citation
Ultra-high vacuum measurement and extremely high vacuum (UHV/XHV) measurement play an important role in high-tech fields such as deep space exploration, particle accelerators, and nanoscience; with the continuous extension of the lower limit of measurement, especially when it reaches the order of 10–10 Pa, higher requirements are placed on the accuracy of the measurement. At present, in the field of UHV/XHV measurement, ionization gauges based on the principle of neutral gas ionization are commonly applied to the vacuum measurement. However, traditional ionization vacuum gauges during use can create electronic excitation desorption effects, soft X-rays, and the effect of hot cathode outgassing, thereby affecting the accuracy of measurement and limiting the lower limit of measurement. Compared with the traditional measurement technology, this method uses the relationship between the loss rate and pressure caused by the collision of cold atoms trapped in the trap depth with the background gas to calculate the gas density and inversely calculate the vacuum pressure. Based on the intrinsic quantum mechanical properties of cold atom collisions, this method is expected to be developed into a new vacuum traceability standard. In this paper, based on the small-angle approximation and impulse approximation under the quantum scattering theory, the loss rate coefficient of the collision of 6Li cold atoms with background gas molecules is calculated. According to the ideal gas equation, the pressure inversion formula is obtained. The collision loss rate is extracted by accurately fitting the loss curve of the cold atom. In order to improve the accuracy of vacuum inversion and reduce the influence of quantum diffractive collision on loss rate measurement, the trap depth under the conditions of a certain cooling laser intensity, detuning, and magnetic field gradient is determined by the photoassociation method. Finally, in a range of 1 × 10–8–5 × 10–6 Pa, the inverted pressure value is compared with the measured value of the ionization meter, proving that this method has good accuracy and reliability in the inversion of vacuum pressure. At present, the main factor restricting the improvement of accuracy is the influence of the collision between the excited atoms in the magneto-optical trap and the background gas on the loss rate measurement. In the future, with the proportion of excited atoms and the excited state C6 coefficient to be precisely determined, the uncertainty of vacuum pressure measurement can be further reduced.
The redefinition of the International System of Units (SI) promotes the transformation of the vacuum measurement system toward quantization, and the quantization of vacuum parameters is one of the most leading, prospective and subversive research directions in the field of international vacuum metrology, and the quantum vacuum measurement is based on the quantum effect of the microscopic particle system, and the use of optical means and the theory of quantum mechanics to realize the precision measurement of the vacuum parameters. We develop a lithium-cooled atom vacuum measurement apparatus, which mainly consists of a 7Li atom trap system and a continuous expansion vacuum system. In this work, an experimental study of ultrahigh vacuum measurement is carried out by manipulating 7Li atoms and utilizing the loss characteristics of lithium cold atoms in magneto-optical and magnetic traps, and the results show that for the four commonly used gas molecules in vacuum, namely N2, Ar, He, and H2, in the vacuum range of (3×10–8–4×10–5) Pa, the maximum measurement uncertainty is 7.6%–6.0% (k = 2) based on 7Li cold atoms, and the cold atom vacuum measurement results are in good agreement with those of the traditional ionization vacuum gauges, and their relative sensitivities are in good agreement with those of the ionization vacuum gauges, and the maximal deviation of the relative sensitivity factor is less than 8%, which verifies the accuracy and reliability of the cold-atom quantum vacuum measurements. The research results are of great significance in promoting the development of new cross-generation vacuum measurement technology and meeting the needs of space science exploration, ultra-precision measurement and high-end equipment manufacturing.
We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.
Cold atoms play a very important role in metrology. The ultra-high or extreme-high vacuum pressure can be accurately measured by investigating the collision of cold atoms and residual atoms in the environment. We report a vacuum pressure metrometer using cold 7Li atoms as sensor atoms in a magneto-optical trap and a magnetic trap. The accuracy, uncertainty, and feasibility of the measurements in such two different traps are studied and compared in the pressure range from 10−5 to 10−8 Pa. It is found that the vacuum pressure measurement in a magneto-optical trap is more advantageous with a higher accuracy, higher signal-to-noise ratio, and shorter measurement time under current conditions. The results may be used to realize an applicable cold atom quantum vacuum standard.
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.
This thesis describes a method of using an ultra-cold ensemble of atoms confined in a trap as an atomic primary pressure standard. The development of the standard and its current status are described in detail. This standard uses a 3D MOT to trap ⁸⁷Rb and then transfer them to a quadrupole magnetic trap where the atoms undergoes collisions with a background gas. By measuring the number of atoms left in the magnetic trap as a function of time one extract a loss rate and from this rate determine the background gas density. This loss rate is a product of the density of the background, multiplied by the loss cross section averaged over the velocity distribution of the background gas. By computing the average loss cross section in the magnetic trap and measuring the loss rate, the density of the background gas can be determined. This gives a calibration free measurement of density of a background gas in the UHV range (10-⁶ ‑ 10-⁹) Torr or (10-⁴ - 10-⁷) Pa which allows for it to be used as a standard. In conjunction with this, preparation of the atoms prior to the loss rate measurement is investigated to ensure accuracy and reproducibility of the standard. Finally a comparison between UBC's atomic standard and NIST's (National Institute for Standards and Technology) orifice flow standard is conducted via an ionization gauge which employed as a transfer standard.All measurement are carried out using Argon gas as the background gas of study.
Quantum metrology technology is an advanced measurement method, which can achieve the accuracy that classical metrology is difficult to measure, and supplement the accuracy and stability defects caused by the standard quantum limit. In addition, reproducing quantum effects and quantum phenomena into units of metrology, which is obviously superior to the traditional measurement technology in terms of measurement accuracy, sensitivity and stability that could realize the quantum value transfer and traceability activities. With the development of laser cooling and trapping atom technology, the pressure measurement range of cold atom quantum-based vacuum metrology(CAVM) may reach 10-4~10-10 Pa or even lower . Benefiting from the loss rate of cold atoms in CAVM is only controlled by the collision cross section between cold atoms and gases, CAVM has the potential to develop into a emerging generation of vacuum metrology technology27. In this paper, the basic concept, structure and working principle of magneto-optical traps(MOT) for laser cooling atoms and trapping atoms are briefly described; Then, the basic principle of the CAVM is introduced. Furthermore, through collecting and sorting out a large number of literature about this technology, the advantages and key technologies of this technique in recent years are comprehensively analyzed and summarized; Finally, the developing trend of the CAVM is prospected.