Applied Sciences

Towards Quantum 3D Imaging Devices

Cristoforo Abbattista, Leonardo Amoruso, Samuel Burri, Edoardo Charbon A, Francesco Di Lena, Augusto Garuccio, Davide Giannella, Z. Hradil, Michele Iacobellis, Gianlorenzo Massaro, Paul Moş, L. Motka, Martin Paùr, Francesco Vincenzo Pepe, Michal Peterek, Isabella Petrelli, Jaroslav Řeháček, Francesca Santoro, Francesco Scattarella, Arin Can Ülkü, Sergii Vasiukov, Michael A. Wayne, Claudio E. Bruschini, Milena D’Angelo, Maria Ieronymaki, B. Stoklasa

Published Jul 12, 2021• 29 citations
Publisher

Abstract

We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum–position entanglement and photon–number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also developing dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable signal-to-noise ratio, quantum plenoptic imaging (QPI) would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are developing high-resolution single-photon avalanche photodiode (SPAD) arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.

DOI
10.3390/app11146414

Related papers

Towards quantum 3D imaging devices: the Qu3D project

Cristoforo Abbattista, Leonardo Amoruso, Samuel Burri +23 more

We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum-position entanglement and photon-number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also developing dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable SNR, quantum plenoptic imaging would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are developing high-resolution SPAD arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.

arXiv:2106.07826•Jun 15, 2021•0 citations

Towards quantum 3D imaging devices

Gianlorenzo Massaro, Cristoforo Abbattista, Leonardo Amoroso +23 more

We introduce a new generation of 3D imaging devices based on quantum plenoptic imaging. Position-momentum entanglement and photon number correlations are exploited to provide a scan-free 3D image after post-processing of the collected light intensity signal. We explore the steps toward designing and implementing quantum plenop- tic cameras with dramatically improved performances, unattainable in standard plenoptic cameras, such as diffraction-limited resolution, large depth of focus, and ultra-low noise. However, to make these new types of devices attractive to end-users, two main challenges need to be tackled: the reduction of the acquisition times, that for the commercially available high-resolution cameras would be from tens of seconds to a few minutes, and a speed-up in processing the large amount of data that are acquired, in order to retrieve 3D reconstructions or refocused 2D images. To address these challenges, we are employing high-resolution SPAD (single photon avalanche diode) arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim of reducing both the acquisition and the elaboration time by one or possibly two orders of magnitude. Moreover, in order to achieve the quantum limit and further increase the volumetric resolution beyond the Rayleigh diffraction limit, we explored dedicated pro- tocols based on quantum Fisher information. Finally, we discuss how this new generation of quantum plenoptic devices could be exploited in different fields of research, such as 3D microscopy and space imaging.

Photonics for Quantum (PfQ)•Jul 9, 2021•2 citations

Quantum-enhanced plenoptic imaging

Gianlorenzo Massaro, Francesco Di Lena, Davide Giannella +4 more

We will show that photon correlations can be employed to overcome the typical limitations of conventional plenoptic imaging devices, thus leading to quantum-enhanced plenoptic imaging. In particular, we will show an unprecedented combination of resolution and depth of field combined with refocusing capability and depth extension. We will show experimental results obtained in different application scenarios, ranging from microscopy to photography-like protocols. Significant advances in acquisition speed will also be discussed, as achieved by both hardware (e.g., use of SPAD arrays, as opposed to common CMOS and CCD cameras) and software (e.g., compressive sensing, quantum tomography) solutions.

Quantum Communications and Quantum Imaging•Oct 3, 2022•0 citations

Correlation Plenoptic Imaging With Entangled Photons

Francesco Vincenzo Pepe, Francesco Di Lena, Augusto Garuccio +2 more

Plenoptic imaging is a novel optical technique for three-dimensional imaging in a single shot. It is enabled by the simultaneous measurement of both the location and the propagation direction of light in a given scene. In the standard approach, the maximum spatial and angular resolutions are inversely proportional, and so are the resolution and the maximum achievable depth of focus of the 3D image. We have recently proposed a method to overcome such fundamental limits by combining plenoptic imaging with an intriguing correlation remote-imaging technique: ghost imaging. Here, we theoretically demonstrate that correlation plenoptic imaging can be effectively achieved by exploiting the position-momentum entanglement characterizing spontaneous parametric down-conversion (SPDC) photon pairs. As a proof-of-principle demonstration, we shall show that correlation plenoptic imaging with entangled photons may enable the refocusing of an out-of-focus image at the same depth of focus of a standard plenoptic device, but without sacrificing diffraction-limited image resolution.

arXiv:1606.02263•Technologies•Jun 7, 2016•58 citations

Plenoptic imaging through correlation

Francesco Di Lena, Francesco Vincenzo Pepe, Aldo Mazzilli +3 more

Traditional optical imaging is characterized by the typical trade-off between resolution and depth of field (DOF). In order to increase resolution, high numerical apertures (NA) are needed, but the associated large angular uncertainty results in a limited range of depths that can be put in sharp focus. Plenoptic imaging (PI) is a promising optical modality that simultaneously captures the location and the propagation direction of light in order to enable refocusing of the acquired images. Thanks to its ability to simultaneously acquire multi-perspective images, plenoptic imaging is one of the most promising technologies for 3D imaging. However, the improvement offered by standard plenoptic imaging is practical rather than fundamental: the increased DOF leads to a proportional reduction of the resolution well above the diffraction limit imposed by the lens NA. We have recently demonstrated that the intrinsic correlation of both chaotic light and entangled photons enables pushing plenoptic imaging to its fundamental limits of both resolution and DOF. In this paper we demonstrate correlation plenoptic imaging (CPI) of a double slit and present the comparison between theoretical prediction and experimental images.

Il Nuovo Cimento C•May 1, 2018•0 citations

Enhanced Quantum Imaging SPAD arrays

Federica Villa, Fabio Severini, Francesca Madonini +1 more

Quantum techniques are commonly used to enhance measurement performance in many fields, such as imaging, microscopy, communications, computing and metrology. In quantum imaging and microscopy, entangled photons are exploited to improve image resolution and sensitivity, overcoming the diffraction limit and providing Sub-Shot Noise (SSN) measurements [1] . Super resolution imaging, SSN imaging, quantum-enhanced displacement sensing, correlation plenoptic imaging and ghost imaging are different quantum techniques used to enhance image quality. All them require time-resolved single-photon detectors, capable to detect photon coincidences with sub-nanosecond precision.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•0 citations
We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum–position entanglement and photon–number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also developing dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable signal-to-noise ratio, quantum plenoptic imaging (QPI) would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are developing high-resolution single-photon avalanche photodiode (SPAD) arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.
We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum-position entanglement and photon-number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also developing dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable SNR, quantum plenoptic imaging would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are developing high-resolution SPAD arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.
We introduce a new generation of 3D imaging devices based on quantum plenoptic imaging. Position-momentum entanglement and photon number correlations are exploited to provide a scan-free 3D image after post-processing of the collected light intensity signal. We explore the steps toward designing and implementing quantum plenop- tic cameras with dramatically improved performances, unattainable in standard plenoptic cameras, such as diffraction-limited resolution, large depth of focus, and ultra-low noise. However, to make these new types of devices attractive to end-users, two main challenges need to be tackled: the reduction of the acquisition times, that for the commercially available high-resolution cameras would be from tens of seconds to a few minutes, and a speed-up in processing the large amount of data that are acquired, in order to retrieve 3D reconstructions or refocused 2D images. To address these challenges, we are employing high-resolution SPAD (single photon avalanche diode) arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim of reducing both the acquisition and the elaboration time by one or possibly two orders of magnitude. Moreover, in order to achieve the quantum limit and further increase the volumetric resolution beyond the Rayleigh diffraction limit, we explored dedicated pro- tocols based on quantum Fisher information. Finally, we discuss how this new generation of quantum plenoptic devices could be exploited in different fields of research, such as 3D microscopy and space imaging.
We will show that photon correlations can be employed to overcome the typical limitations of conventional plenoptic imaging devices, thus leading to quantum-enhanced plenoptic imaging. In particular, we will show an unprecedented combination of resolution and depth of field combined with refocusing capability and depth extension. We will show experimental results obtained in different application scenarios, ranging from microscopy to photography-like protocols. Significant advances in acquisition speed will also be discussed, as achieved by both hardware (e.g., use of SPAD arrays, as opposed to common CMOS and CCD cameras) and software (e.g., compressive sensing, quantum tomography) solutions.
Plenoptic imaging is a novel optical technique for three-dimensional imaging in a single shot. It is enabled by the simultaneous measurement of both the location and the propagation direction of light in a given scene. In the standard approach, the maximum spatial and angular resolutions are inversely proportional, and so are the resolution and the maximum achievable depth of focus of the 3D image. We have recently proposed a method to overcome such fundamental limits by combining plenoptic imaging with an intriguing correlation remote-imaging technique: ghost imaging. Here, we theoretically demonstrate that correlation plenoptic imaging can be effectively achieved by exploiting the position-momentum entanglement characterizing spontaneous parametric down-conversion (SPDC) photon pairs. As a proof-of-principle demonstration, we shall show that correlation plenoptic imaging with entangled photons may enable the refocusing of an out-of-focus image at the same depth of focus of a standard plenoptic device, but without sacrificing diffraction-limited image resolution.
Traditional optical imaging is characterized by the typical trade-off between resolution and depth of field (DOF). In order to increase resolution, high numerical apertures (NA) are needed, but the associated large angular uncertainty results in a limited range of depths that can be put in sharp focus. Plenoptic imaging (PI) is a promising optical modality that simultaneously captures the location and the propagation direction of light in order to enable refocusing of the acquired images. Thanks to its ability to simultaneously acquire multi-perspective images, plenoptic imaging is one of the most promising technologies for 3D imaging. However, the improvement offered by standard plenoptic imaging is practical rather than fundamental: the increased DOF leads to a proportional reduction of the resolution well above the diffraction limit imposed by the lens NA. We have recently demonstrated that the intrinsic correlation of both chaotic light and entangled photons enables pushing plenoptic imaging to its fundamental limits of both resolution and DOF. In this paper we demonstrate correlation plenoptic imaging (CPI) of a double slit and present the comparison between theoretical prediction and experimental images.
Quantum techniques are commonly used to enhance measurement performance in many fields, such as imaging, microscopy, communications, computing and metrology. In quantum imaging and microscopy, entangled photons are exploited to improve image resolution and sensitivity, overcoming the diffraction limit and providing Sub-Shot Noise (SSN) measurements [1] . Super resolution imaging, SSN imaging, quantum-enhanced displacement sensing, correlation plenoptic imaging and ghost imaging are different quantum techniques used to enhance image quality. All them require time-resolved single-photon detectors, capable to detect photon coincidences with sub-nanosecond precision.