Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE photonics journal

High-Resolution Determination of Kinetic Parameters of Sucrose Hydrolysis Based on Weak Measurement

Peng Tang, Yetao Shu, Zhaoxin Wen, Yifei Song, Shuoqing Liu, Ting Wan, Zhaoming Luo

Published Jan 11, 2022• 12 citations
Publisher

Abstract

We propose a high-resolution scheme for determining the kinetic parameters of sucrose hydrolysis based on the weak measurement, and the parameters including rate constant, half-life, activation energy and pre-exponential factor are experimentally determined. In the scheme, the postselection state of weak measurement is modified by the optical rotation angle in the process of sucrose hydrolysis, and the amplified spin-Hall shift acts as a probe for determining the kinetic parameters. The rate constant and half-life are obtained based on the time variations of amplified spin-Hall shifts under different reaction conditions of temperatures and hydrochloric acid concentrations. The corresponding activation energy and pre-exponential factor are also evaluated for explaining the physical mechanism which influences the rate constant and analyzing how to adjust the reaction conditions to predict or control the rate. The high resolution for optical rotation angle is achieved in our scheme, which can reach${\rm {4}}{\rm {.9}} \times {\rm {10}}^{\rm {-4}}$degree with one order of magnitude improvement over the polarimeter. These results can provide a possibility for the determination of chemical kinetic parameters with high-precision, real-time, label-free and convenient effects.

DOI
10.1109/jphot.2022.3142072

Related papers

Ultrasensitive and real-time detection of chemical reaction rate based on the photonic spin Hall effect

Ruisi Wang, Junxiao Zhou, Kuiming Zeng +5 more

A chemical reaction is a process that leads to the chemical transformation of one set of chemical substances to another. However, the precise and real-time detection of the reaction rate remains challenging due to its fast and dynamical process. In this paper, the photonic spin Hall effect is proposed to realize the ultrasensitive and real-time detection of the reaction rate of sucrose hydrolysis. By incorporating with quantum weak measurement, the photonic spin-Hall shift acts as the measurement pointer, and the optical rotation in the process of sucrose hydrolysis acts as the postselection state. The high measurement resolution with 1.25 × 10−4 degree is achieved due to the weak-value amplification in quantum weak measurement which outperforms the standard polarimeter. In our scheme, the amplified measurement pointer is real-time monitoring the chemical reaction process. It does not involve any mechanical adjustment of optical elements once the experimental setup is established and thereby realizes a real-time detection of the dynamic chemical reaction.

APL Photonics•Jan 1, 2020•145 citations

Real-time monitoring of the sucrose hydrolysis process based on two-photon coincidence measurements

Zheng Peng, Zhi‐Yuan Zhou, Tongju Li +5 more

Real-time measurement of the biochemical reaction process has important application scenarios. Due to the chirality of a large number of life-sustaining molecules, many parameters of the reaction kinetics involving these chiral molecules, such as the reaction rate and the reagents concentrations, could be tracked by monitoring the optical activity of the substrate and/or product molecules. However, the optical activity of photosensitive biomolecules does not allow traditional laser-based real-time measurement due to the vulnerability of their biochemical properties under high-intensity light regimes. Here we introduce a real-time tracking technique of the sucrose hydrolysis reaction based on two-photon coincidence measurements. The two-photon source is generated based on a spontaneous parametric down-conversion process. During the reaction, the kinetic parameters are obtained by the real-time measurement of the change of the polarization of the photons when operating at extremely low-light regimes. Compared with single-photon counting measurements, two-photon coincidence measurements have higher signal-to-noise ratios and better robustness, which demonstrates the potential value in monitoring the photosensitive biochemical reaction processes.

Biomedical Optics Express•Sep 22, 2021•8 citations

Estimation of optical rotation of chiral molecules with weak measurements

Xiaodong Qiu, Linguo Xie, Xiong Liu +3 more

From its beginning, the measurement of optical rotation (OR) is crucial for the analysis of chiral molecules in many fields. However, the precision measurement of a weak OR signal with conventional setup remains elusive. In this Letter, we experimentally propose a precision method to determine the OR of glucose and fructose based on weak measurements. By using the spin Hall effect of light (SHEL) as a probe, a nonlinear weak measurements model is established that is applicable beyond the Aharonov-Albert-Vaidman (AAV) limit. Due to the high sensitivity of weak measurements amplification with respect to the OR, a tremendous variation of the amplified beam displacement of the SHEL is observed, while the concentration of glucose and fructose is slightly changed.

Optics Letters•Aug 23, 2016•138 citations

Quantum sensing for dynamical tracking of chemical processes

Valeria Cimini, Ilaria Gianani, Ludovica Ruggiero +7 more

Quantum photonics has demonstrated its potential for enhanced sensing. Current sources of quantum light states tailored to measuring allow one to monitor phenomena evolving on timescales of second order. These are characteristic of product accumulation in chemical reactions of technological interest, in particular those involving chiral compounds. Here we adopt a quantum multiparameter approach to investigate the dynamic process of sucrose acid hydrolysis as a test bed for such applications. The estimation is made robust by monitoring different parameters at once.

arXiv:1901.05385•Physical Review A•May 13, 2019•29 citations

Weak value amplification of Geometric Spin Hall shift of light beam

Sumit Goswami, Nirmalya Ghosh, Mandira Pal +1 more

Geometric Spin Hall effect of light (SHEL) has attracted considerable attention because of the universality of this variant of the spin Hall shift and its independence on the light-matter interactions and materials properties. However, the magnitude of geometric SHEL is typically very small, in the sub-wavelength domain, making it difficult for direct experimental observation. Here, we have applied weak measurement schemes to amplify and faithfully observe the geometric SHEL. In our experiment, the input beam is pre-selected in linear polarization basis (p- or slinear polarization) and post selections are done at nearly orthogonal linear polarizations (small angle ϵ away from the exact orthogonal).This results in weak value amplification (~cotϵ) of the resulting shift of the beam centroid. Moreover, this process also leads to selective conversion of spatial to angular nature of geometric SHEL, which along with the weak value amplification leads to manifold amplification of the resulting SHEL, enabling its reliable experimental detection. A key feature of our weak measurement scheme is that both the weak perturbation (tiny geometric SHEL) and the post selection are done simultaneously by a single optical element, namely, a linear polarizer. The dependence of the weak value of the geometric SHEL on the pre and the post selection of polarization states in both linear and elliptical basis were also investigated in details. The specifics of the different weak measurement schemes, various intriguing experimental manifestations of the weak value amplified geometric SHEL, their analysis / interpretation via polarization operator based treatment of weak measurements is presented here.

SPIE Nanophotonics•May 4, 2018•0 citations

Optimal preselection and postselection in weak measurements for observing photonic spin Hall effect

Xinxing Zhou, Xing Li, Hailu Luo +1 more

Photonic spin Hall effect (SHE) holds great potential applications in precision metrology. How to obtain a high measurement precision is an important issue to detect the photonic SHE. In this Letter, we propose using optimal preselection and postselection in weak measurements to enhance the measurement precision. We find that the maximum weak value and pointer shift can be obtained with an optimal overlap of preselection and postselection states. These findings offer the possibility for improving the precision of weak measurements and thereby have possible applications for accurately characterizing the parameters of nanostructures.

arXiv:1404.2721•Applied Physics Letters•Feb 3, 2014•51 citations
We propose a high-resolution scheme for determining the kinetic parameters of sucrose hydrolysis based on the weak measurement, and the parameters including rate constant, half-life, activation energy and pre-exponential factor are experimentally determined. In the scheme, the postselection state of weak measurement is modified by the optical rotation angle in the process of sucrose hydrolysis, and the amplified spin-Hall shift acts as a probe for determining the kinetic parameters. The rate constant and half-life are obtained based on the time variations of amplified spin-Hall shifts under different reaction conditions of temperatures and hydrochloric acid concentrations. The corresponding activation energy and pre-exponential factor are also evaluated for explaining the physical mechanism which influences the rate constant and analyzing how to adjust the reaction conditions to predict or control the rate. The high resolution for optical rotation angle is achieved in our scheme, which can reach4.9×10−4{\rm {4}}{\rm {.9}} \times {\rm {10}}^{\rm {-4}}4.9×10−4degree with one order of magnitude improvement over the polarimeter. These results can provide a possibility for the determination of chemical kinetic parameters with high-precision, real-time, label-free and convenient effects.
A chemical reaction is a process that leads to the chemical transformation of one set of chemical substances to another. However, the precise and real-time detection of the reaction rate remains challenging due to its fast and dynamical process. In this paper, the photonic spin Hall effect is proposed to realize the ultrasensitive and real-time detection of the reaction rate of sucrose hydrolysis. By incorporating with quantum weak measurement, the photonic spin-Hall shift acts as the measurement pointer, and the optical rotation in the process of sucrose hydrolysis acts as the postselection state. The high measurement resolution with 1.25 × 10−4 degree is achieved due to the weak-value amplification in quantum weak measurement which outperforms the standard polarimeter. In our scheme, the amplified measurement pointer is real-time monitoring the chemical reaction process. It does not involve any mechanical adjustment of optical elements once the experimental setup is established and thereby realizes a real-time detection of the dynamic chemical reaction.
Real-time measurement of the biochemical reaction process has important application scenarios. Due to the chirality of a large number of life-sustaining molecules, many parameters of the reaction kinetics involving these chiral molecules, such as the reaction rate and the reagents concentrations, could be tracked by monitoring the optical activity of the substrate and/or product molecules. However, the optical activity of photosensitive biomolecules does not allow traditional laser-based real-time measurement due to the vulnerability of their biochemical properties under high-intensity light regimes. Here we introduce a real-time tracking technique of the sucrose hydrolysis reaction based on two-photon coincidence measurements. The two-photon source is generated based on a spontaneous parametric down-conversion process. During the reaction, the kinetic parameters are obtained by the real-time measurement of the change of the polarization of the photons when operating at extremely low-light regimes. Compared with single-photon counting measurements, two-photon coincidence measurements have higher signal-to-noise ratios and better robustness, which demonstrates the potential value in monitoring the photosensitive biochemical reaction processes.
From its beginning, the measurement of optical rotation (OR) is crucial for the analysis of chiral molecules in many fields. However, the precision measurement of a weak OR signal with conventional setup remains elusive. In this Letter, we experimentally propose a precision method to determine the OR of glucose and fructose based on weak measurements. By using the spin Hall effect of light (SHEL) as a probe, a nonlinear weak measurements model is established that is applicable beyond the Aharonov-Albert-Vaidman (AAV) limit. Due to the high sensitivity of weak measurements amplification with respect to the OR, a tremendous variation of the amplified beam displacement of the SHEL is observed, while the concentration of glucose and fructose is slightly changed.
Quantum photonics has demonstrated its potential for enhanced sensing. Current sources of quantum light states tailored to measuring allow one to monitor phenomena evolving on timescales of second order. These are characteristic of product accumulation in chemical reactions of technological interest, in particular those involving chiral compounds. Here we adopt a quantum multiparameter approach to investigate the dynamic process of sucrose acid hydrolysis as a test bed for such applications. The estimation is made robust by monitoring different parameters at once.
Geometric Spin Hall effect of light (SHEL) has attracted considerable attention because of the universality of this variant of the spin Hall shift and its independence on the light-matter interactions and materials properties. However, the magnitude of geometric SHEL is typically very small, in the sub-wavelength domain, making it difficult for direct experimental observation. Here, we have applied weak measurement schemes to amplify and faithfully observe the geometric SHEL. In our experiment, the input beam is pre-selected in linear polarization basis (p- or slinear polarization) and post selections are done at nearly orthogonal linear polarizations (small angle ϵ away from the exact orthogonal).This results in weak value amplification (~cotϵ) of the resulting shift of the beam centroid. Moreover, this process also leads to selective conversion of spatial to angular nature of geometric SHEL, which along with the weak value amplification leads to manifold amplification of the resulting SHEL, enabling its reliable experimental detection. A key feature of our weak measurement scheme is that both the weak perturbation (tiny geometric SHEL) and the post selection are done simultaneously by a single optical element, namely, a linear polarizer. The dependence of the weak value of the geometric SHEL on the pre and the post selection of polarization states in both linear and elliptical basis were also investigated in details. The specifics of the different weak measurement schemes, various intriguing experimental manifestations of the weak value amplified geometric SHEL, their analysis / interpretation via polarization operator based treatment of weak measurements is presented here.
Photonic spin Hall effect (SHE) holds great potential applications in precision metrology. How to obtain a high measurement precision is an important issue to detect the photonic SHE. In this Letter, we propose using optimal preselection and postselection in weak measurements to enhance the measurement precision. We find that the maximum weak value and pointer shift can be obtained with an optimal overlap of preselection and postselection states. These findings offer the possibility for improving the precision of weak measurements and thereby have possible applications for accurately characterizing the parameters of nanostructures.