Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Wiley eBooks

Detecting Neutral Atoms on an Atom Chip

Marco Wilzbach, Albrecht Haase, Michael Schwarz, Dennis Heine, Kai Wicker, Xiyuan Liu, Karl‐Heinz Brenner, S. Groth, T. Fernholz, Björn Hessmo, Jörg Schmiedmayer

Published Jan 26, 2007• 1 citation
Publisher

Abstract

This chapter contains sections titled: Introduction Detecting Single Atoms Measuring the Scattered Light: Fluorescence Detection Measuring the Driving Field Absorption on Resonance Refraction Cavities Absorption on Resonance Refraction Many Atoms in a Cavity Concentric Cavity Miniaturization Properties of Fiber Cavities Loss Mechanisms for a Cavity Losses due to the Gap Length Losses due to Transversal Misalignment Losses due to Angular Misalignment Fresnel Reflections Other Fiber Optical Components for the Atom Chip Fluorescence and Absorption Detectors A Single Mode Tapered Lensed Fiber Dipole Trap Integration of Fibers on the Atom Chip Building Fiber Cavities The SU-8 Resist Test of the SU-8 Structure Pilot Test for Atom Detection with Small Waists Dropping Atoms through a Concentric Cavity Detecting Magnetically Guided Atoms Conclusion References

DOI
10.1002/9783527611065.ch8

Related papers

Detecting neutral atoms on an atom chip

M. Wilzbach, A. Haase, M. Schwarz +8 more

Abstract Detecting single atoms (qubits) is a key requirement for implementing quantum information processing on an atom chip. The detector should ideally be integrated on the chip. Here we present and compare different methods capable of detecting neutral atoms on an atom chip. After a short introduction to fluorescence and absorption detection we discuss cavity enhanced detection of single atoms. In particular we concentrate on optical fiber based detectors such as fiber cavities and tapered fiber dipole traps. We discuss the various constraints in building such detectors in detail along with the current implementations on atom chips. Results from experimental tests of fiber integration are also described. In addition we present a pilot experiment for atom detection using a concentric cavity to verify the required scaling.

arXiv:physics/0608189•Fortschritte der Physik•Aug 1, 2006•12 citations

Single atom detection on an atom chip with integrated optics

Marco Wilzbach

The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.

•Jan 1, 2007•0 citations

Fiber optics for quantum computers

Steve Helsby, Hebe Powell, Péter Horák +2 more

Abstract: We describe schemes for the integration of miniature optical components onto Atom Chips, for the manipulation and detection of ultra-cold atoms. Our intention is to build detectors sensitive enough to accurately detect single atoms. Two approaches are discussed: simple fluorescence detection and the use of a resonant cavity. Theory predicts that cavities with F>100 should be sufficient to obtain signal to noise ratios high enough to detect single atoms. The first micro cavities were demonstrated using mirrors formed by cleaved fiber ends coated with a stick-on dielectric coating to give F ∼100. A more successful approach involves the full integration of the mirrors and fibers by using Bragg gratings written into the fiber core: it has been possible to form gap cavities with F ~ 150. 1.

•Jan 1, 2004•0 citations

A single-atom detector integrated on an atom chip: fabrication, characterization and application

Dennis Heine, Wolfgang Rohringer, D Fischer +7 more

We describe a robust and reliable fluorescence detector for single atoms that is fully integrated on an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single-atom detection efficiency of 66%. It consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multi-mode fiber to collect the fluorescence. The fibers are mounted in lithographically defined holding structures on the atom chip. Neutral 87 Rb atoms propagating freely in a magnetic guide are detected and the noise of their fluorescence emission is analyzed. The variance of the photon distribution allows us to determine the number of detected photons per atom and from there the atom detection efficiency. The second-order intensity correlation function of the fluorescence shows near-perfect photon anti-bunching and signs of damped Rabi oscillations. With simple improvements, one can increase the detection efficiency to 95%.

arXiv:1002.1573•New Journal of Physics•Sep 9, 2010•30 citations

Simple integrated single-atom detector

Marco Wilzbach, Dennis Heine, S. Groth +4 more

We present a reliable and robust integrated fluorescence detector capable of detecting single atoms. The detector consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multimode fiber to collect the fluorescence. Both are mounted in lithographically defined SU-8 holding structures on an atom chip. 87Rb atoms propagating freely in a magnetic guide are detected with an efficiency of up to 66%, and a signal-to-noise ratio in excess of 100 is obtained for short integration times.

arXiv:0801.3255•Optics Letters•Jan 23, 2009•32 citations

Resonator-Aided Single-Atom Detection on a Microfabricated Chip

Igor Teper, Y.-J. Lin, Vladan Vuletić

We use an optical cavity to detect single atoms magnetically trapped on an atom chip. We implement the detection using both fluorescence into the cavity and atom-induced reduction in cavity transmission. In fluorescence, we register 2.0(2) photon counts per atom, which allows us to detect single atoms with 75% efficiency in 250 micros. In absorption, we measure transmission attenuation of 3.3(3)% per atom, which allows us to count small numbers of atoms with a resolution of about 1 atom.

arXiv:cond-mat/0603675•Physical Review Letters•Jul 14, 2006•73 citations
This chapter contains sections titled: Introduction Detecting Single Atoms Measuring the Scattered Light: Fluorescence Detection Measuring the Driving Field Absorption on Resonance Refraction Cavities Absorption on Resonance Refraction Many Atoms in a Cavity Concentric Cavity Miniaturization Properties of Fiber Cavities Loss Mechanisms for a Cavity Losses due to the Gap Length Losses due to Transversal Misalignment Losses due to Angular Misalignment Fresnel Reflections Other Fiber Optical Components for the Atom Chip Fluorescence and Absorption Detectors A Single Mode Tapered Lensed Fiber Dipole Trap Integration of Fibers on the Atom Chip Building Fiber Cavities The SU-8 Resist Test of the SU-8 Structure Pilot Test for Atom Detection with Small Waists Dropping Atoms through a Concentric Cavity Detecting Magnetically Guided Atoms Conclusion References
Abstract Detecting single atoms (qubits) is a key requirement for implementing quantum information processing on an atom chip. The detector should ideally be integrated on the chip. Here we present and compare different methods capable of detecting neutral atoms on an atom chip. After a short introduction to fluorescence and absorption detection we discuss cavity enhanced detection of single atoms. In particular we concentrate on optical fiber based detectors such as fiber cavities and tapered fiber dipole traps. We discuss the various constraints in building such detectors in detail along with the current implementations on atom chips. Results from experimental tests of fiber integration are also described. In addition we present a pilot experiment for atom detection using a concentric cavity to verify the required scaling.
The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.
Abstract: We describe schemes for the integration of miniature optical components onto Atom Chips, for the manipulation and detection of ultra-cold atoms. Our intention is to build detectors sensitive enough to accurately detect single atoms. Two approaches are discussed: simple fluorescence detection and the use of a resonant cavity. Theory predicts that cavities with F>100 should be sufficient to obtain signal to noise ratios high enough to detect single atoms. The first micro cavities were demonstrated using mirrors formed by cleaved fiber ends coated with a stick-on dielectric coating to give F ∼100. A more successful approach involves the full integration of the mirrors and fibers by using Bragg gratings written into the fiber core: it has been possible to form gap cavities with F ~ 150. 1.
We describe a robust and reliable fluorescence detector for single atoms that is fully integrated on an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single-atom detection efficiency of 66%. It consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multi-mode fiber to collect the fluorescence. The fibers are mounted in lithographically defined holding structures on the atom chip. Neutral 87 Rb atoms propagating freely in a magnetic guide are detected and the noise of their fluorescence emission is analyzed. The variance of the photon distribution allows us to determine the number of detected photons per atom and from there the atom detection efficiency. The second-order intensity correlation function of the fluorescence shows near-perfect photon anti-bunching and signs of damped Rabi oscillations. With simple improvements, one can increase the detection efficiency to 95%.
We present a reliable and robust integrated fluorescence detector capable of detecting single atoms. The detector consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multimode fiber to collect the fluorescence. Both are mounted in lithographically defined SU-8 holding structures on an atom chip. 87Rb atoms propagating freely in a magnetic guide are detected with an efficiency of up to 66%, and a signal-to-noise ratio in excess of 100 is obtained for short integration times.