Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Entropy

Improving the Performance of Continuous-Variable Measurement-Device-Independent Quantum Key Distribution via a Noiseless Linear Amplifier

Fan Jing, Weiqi Liu, Lingzhi Kong, Chen He

Published Dec 16, 2021• 4 citations
Publisher

Abstract

In the continuous variable measurement-device-independent quantum key distribution (CV-MDI-QKD) protocol, both Alice and Bob send quantum states to an untrusted third party, Charlie, for detection through the quantum channel. In this paper, we mainly study the performance of the CV-MDI-QKD system using the noiseless linear amplifier (NLA). The NLA is added to the output of the detector at Charlie's side. The research results show that NLA can increase the communication distance and secret key rate of the CV-MDI-QKD protocol. Moreover, we find that the more powerful the improvement of the performance with the longer gain of NLA and the optimum gain is given under different conditions.

DOI
10.3390/e23121691

Related papers

Four-State Modulation in Middle of a Quantum Channel for Continuous-Variable Quantum Key Distribution Protocol with Noiseless Linear Amplifier*

Yu Mao, Qi Liu, Ying Guo +2 more

We characterize a modified continuous-variable quantum key distribution (CV-QKD) protocol with four states in the middle of a quantum channel. In this protocol, two noiseless linear amplifiers (NLAs) are inserted before each detector of the two parts, Alice and Bob, with the purpose of increasing the secret key rate and the maximum transmission distance. We present the performance analysis of the new four-state CV-QKD protocol over a Gaussian lossy and noisy channel. The simulation results show that the NLAs with a reasonable gain g can effectively enhance the secret key rate as well as the maximum transmission distance, which is generally satisfied in practice.

Chinese Physics Letters•Oct 1, 2019•4 citations

Continuous-variable measurement-device-independent quantum key distribution with virtual photon subtraction

Yijia Zhao, Yichen Zhang, Bingjie Xu +2 more

The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.

arXiv:1711.04225•Physical Review A•Apr 17, 2018•62 citations

Continuous-variable measurement-device-independent quantum key distribution using squeezed states

Yichen Zhang, Zhengyu Li, Song Yu +3 more

A continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol using squeezed states is proposed where the two legitimate partners send Gaussian-modulated squeezed states to an untrusted third party to realize the measurement. Security analysis shows that the protocol can not only defend all detector side channels, but also attain higher secret key rates than the coherent-state-based protocol. We also present a method to improve the squeezed-state CV-MDI QKD protocol by adding proper Gaussian noise to the reconciliation side. It is found that there is an optimal added noise to optimize the performance of the protocol in terms of both key rates and maximal transmission distances. The resulting protocol shows the potential of long-distance secure communication using the CV-MDI QKD protocol.

arXiv:1406.0973•Physical Review A•Nov 18, 2014•115 citations

Continuous-variable measurement-device-independent quantum key distribution

Zhengyu Li, Yichen Zhang, Feihu Xu +2 more

We propose a continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, in which detection is conducted by an untrusted third party. Our protocol can defend all detector side channels, which seriously threaten the security of a practical CV QKD system. Its security analysis against arbitrary collective attacks is derived based on the fact that the entanglement-based scheme of CV-MDI QKD is equivalent to the conventional CV QKD with coherent states and heterodyne detection. We find that the maximal total transmission distance is achieved by setting the untrusted third party close to one of the legitimate users. Furthermore, an alternate detection scheme, a special application of CV-MDI QKD, is proposed to enhance the security of the standard CV QKD system.

arXiv:1312.4655•Physical Review A•May 7, 2014•224 citations

Simultaneous measurement-device-independent continuous variable quantum key distribution with realistic detector compensation

Xiaodong Wu, Yi-Jun Wang, Duan Huang +1 more

We propose a novel scheme for measurement-device-independent (MDI) continuous-variable quantum key distribution (CVQKD) by simultaneously conducting classical communication and QKD, which is called “simultaneous MDI-CVQKD” protocol. In such protocol, each sender (Alice, Bob) can superimpose random numbers for QKD on classical information by taking advantage of the same weak coherent pulse and an untrusted third party (Charlie) decodes it by using the same coherent detectors, which could be appealing in practice due to that multiple purposes can be realized by employing only single communication system. What is more, the proposed protocol is MDI, which is immune to all possible side-channel attacks on practical detectors. Security results illustrate that the simultaneous MDI-CVQKD protocol can secure against arbitrary collective attacks. In addition, we employ phase-sensitive optical amplifiers to compensate the imperfection existing in practical detectors. With this technology, even common practical detectors can be used for detection through choosing a suitable optical amplifier gain. Furthermore, we also take the finite-size effect into consideration and show that the whole raw keys can be taken advantage of to generate the final secret key instead of sacrificing part of them for parameter estimation. Therefore, an enhanced performance of the simultaneous MDI-CVQKD protocol can be obtained in finite-size regime.

Frontiers of Physics•Mar 6, 2020•16 citations

Analyzing the performance of CV-MDI QKD under continuous-mode scenarios

Yanhao Sun, Ziyang Chen, Xiangyu Wang +2 more

Continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) can address vulnerabilities on the detection side of a QKD system. The core of this protocol involves continuous-variable Bell measurements performed by an untrusted third party. However, in high-speed systems, spectrum broadening causes Bell measurements to deviate from the ideal single-mode scenario, resulting in mode mismatches, reduced performance, and compromised security. Here, we introduce temporal modes (TMs) to analyze the performance of CV-MDI QKD under continuous-mode scenarios. The mismatch between Bob's transmitting mode and Bell measurement mode has a more significant effect on system performance compared to that on Alice's side. When the Bell receiver is close to Bob and the mismatch is set to just 5%, the transmission distance drastically decreases from 87.96 km to 18.50 km. In comparison, the same mismatch for Alice reduces the distance to 86.83 km. This greater degradation on Bob's side can be attributed to the asymmetry in the data modification step. Furthermore, the mismatch in TM characteristics leads to a significant reduction in the secret key rate by 83% when the transmission distance is set to 15 km, which severely limits the practical usability of the protocol over specific distances. These results indicate that in scenarios involving continuous-mode interference, such as large-scale MDI network setups, careful consideration of each user's TM characteristics is crucial. Rigorous pre-calibration of these modes is essential to ensure the system's reliability and efficiency.

quant-pharXiv:2512.16114•Physical Review Applied•Dec 19, 2025•4 citations
In the continuous variable measurement-device-independent quantum key distribution (CV-MDI-QKD) protocol, both Alice and Bob send quantum states to an untrusted third party, Charlie, for detection through the quantum channel. In this paper, we mainly study the performance of the CV-MDI-QKD system using the noiseless linear amplifier (NLA). The NLA is added to the output of the detector at Charlie's side. The research results show that NLA can increase the communication distance and secret key rate of the CV-MDI-QKD protocol. Moreover, we find that the more powerful the improvement of the performance with the longer gain of NLA and the optimum gain is given under different conditions.
We characterize a modified continuous-variable quantum key distribution (CV-QKD) protocol with four states in the middle of a quantum channel. In this protocol, two noiseless linear amplifiers (NLAs) are inserted before each detector of the two parts, Alice and Bob, with the purpose of increasing the secret key rate and the maximum transmission distance. We present the performance analysis of the new four-state CV-QKD protocol over a Gaussian lossy and noisy channel. The simulation results show that the NLAs with a reasonable gain g can effectively enhance the secret key rate as well as the maximum transmission distance, which is generally satisfied in practice.
The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.
A continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol using squeezed states is proposed where the two legitimate partners send Gaussian-modulated squeezed states to an untrusted third party to realize the measurement. Security analysis shows that the protocol can not only defend all detector side channels, but also attain higher secret key rates than the coherent-state-based protocol. We also present a method to improve the squeezed-state CV-MDI QKD protocol by adding proper Gaussian noise to the reconciliation side. It is found that there is an optimal added noise to optimize the performance of the protocol in terms of both key rates and maximal transmission distances. The resulting protocol shows the potential of long-distance secure communication using the CV-MDI QKD protocol.
We propose a continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, in which detection is conducted by an untrusted third party. Our protocol can defend all detector side channels, which seriously threaten the security of a practical CV QKD system. Its security analysis against arbitrary collective attacks is derived based on the fact that the entanglement-based scheme of CV-MDI QKD is equivalent to the conventional CV QKD with coherent states and heterodyne detection. We find that the maximal total transmission distance is achieved by setting the untrusted third party close to one of the legitimate users. Furthermore, an alternate detection scheme, a special application of CV-MDI QKD, is proposed to enhance the security of the standard CV QKD system.
We propose a novel scheme for measurement-device-independent (MDI) continuous-variable quantum key distribution (CVQKD) by simultaneously conducting classical communication and QKD, which is called “simultaneous MDI-CVQKD” protocol. In such protocol, each sender (Alice, Bob) can superimpose random numbers for QKD on classical information by taking advantage of the same weak coherent pulse and an untrusted third party (Charlie) decodes it by using the same coherent detectors, which could be appealing in practice due to that multiple purposes can be realized by employing only single communication system. What is more, the proposed protocol is MDI, which is immune to all possible side-channel attacks on practical detectors. Security results illustrate that the simultaneous MDI-CVQKD protocol can secure against arbitrary collective attacks. In addition, we employ phase-sensitive optical amplifiers to compensate the imperfection existing in practical detectors. With this technology, even common practical detectors can be used for detection through choosing a suitable optical amplifier gain. Furthermore, we also take the finite-size effect into consideration and show that the whole raw keys can be taken advantage of to generate the final secret key instead of sacrificing part of them for parameter estimation. Therefore, an enhanced performance of the simultaneous MDI-CVQKD protocol can be obtained in finite-size regime.
Continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) can address vulnerabilities on the detection side of a QKD system. The core of this protocol involves continuous-variable Bell measurements performed by an untrusted third party. However, in high-speed systems, spectrum broadening causes Bell measurements to deviate from the ideal single-mode scenario, resulting in mode mismatches, reduced performance, and compromised security. Here, we introduce temporal modes (TMs) to analyze the performance of CV-MDI QKD under continuous-mode scenarios. The mismatch between Bob's transmitting mode and Bell measurement mode has a more significant effect on system performance compared to that on Alice's side. When the Bell receiver is close to Bob and the mismatch is set to just 5%, the transmission distance drastically decreases from 87.96 km to 18.50 km. In comparison, the same mismatch for Alice reduces the distance to 86.83 km. This greater degradation on Bob's side can be attributed to the asymmetry in the data modification step. Furthermore, the mismatch in TM characteristics leads to a significant reduction in the secret key rate by 83% when the transmission distance is set to 15 km, which severely limits the practical usability of the protocol over specific distances. These results indicate that in scenarios involving continuous-mode interference, such as large-scale MDI network setups, careful consideration of each user's TM characteristics is crucial. Rigorous pre-calibration of these modes is essential to ensure the system's reliability and efficiency.